ACBK

AUTOMATIC CALLBACK

INDICATES:

The Automatic Callback feature name and optional feature attributes to be assigned to a Directory Number in a Stored Program Controlled Switch.

DATE:

3/2/2006

BILLING:

CRIS and CABS

APPLICATIONS:

5ESS, CLASS, DMS-100, FETEX-150, GTD-5 EAX, ISDN BRI, SanteraOne, STROM-DCO, TL1


SECTION - POSITION

EXAMPLES

S&E - LH

5ESS
IACBK|999-*ACBC RGBKTYP.C,
      RGBKINTVL.24

IACBK|+ 999-*ACBC RGBKTYP.C,
      RGBKINTVL.24

S&E - FL

5ESS
I1    @@A/TN 732 555-1234/ACBK 999

             or

I1    @@A/TN 732 555-1234/ACBK
      *ACBC RGBKTYP.C, RGBKINTVL.24

I1    @@A/TN 732 555-1234/ACBK
      + *ACBC RGBKTYP.C, RGBKINTVL.24

DMS-100
I1    @@A/TN 732 555-1234/ACBK
      BLGOPT.NOAMA, KEYLST.1-4

             or

I1    @@A/TN 732 555-1234/ACBK


TL1, DCO, FETEX-150-Basic Business Group
I1    @@A/TN 732 555-1234/ACBK ACBG

TL1; ISDN Directory Number
I1    @@A/TN 732 555-1234/ACBK UNRES,
      ACBB.D

TL1; ISDN Directory Number On A Terminal
I1    @@A/TN 732 555-1234/ACBK T UNRES

DCO; FETEX-150 CLASS
I1    @@A/TN 732 555-1234/ACBK ACCL

GTD-5 EAX, SanteraOne
I1    @@A/TN 732 555-1234/ACBK FR

FID RULES/CONSTRAINTS:

  1. T, F, and X order types prohibited for Access Service application.
  2. X action code prohibited on Access Service orders.
  3. 5ESS, TL1, FETEX-150, GTD-5 EAX
    Section: S&E     Position: FL

    The appearance of element data following the FID is required.
  4. DMS-100
    Section: S&E     Position: FL

    The appearance of element data following the FID is optional.
  5. DMS-100
    The FIDs ACBK and Local Area Signaling Service (LASS) are mutually exclusive.

REFERENCES:

  1. 5ESS
    Lucent Technologies, 235-118-257, View 12.9, Keywords RGBKTYP and RGBKINTVL
  2. TL1
    TR-NWT-000199, Subscriber Lines View, Keyword ACB; DNCT View Keywords ACB, ACBB; TSPDNCT View, Keyword ACB.
  3. FETEX-150
    Fujitsu, ES11X-1511-H72, Keyword ACB.
  4. DMS-100
    NORTEL Preliminary Documentation Feature AF7454, Option ABC.
  5. GTD-5 EAX
    AG Communication Systems, DNCT View, Keyword ACB
  6. SanteraOne
    Santera Systems Inc., DNCT View, Keyword ACB.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - LH

Required

Alphanumeric

3

27

Element: 1

CRIS Non-Retention Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

1

No

No

Code Set:

CodeMeaning
+ (Plus Sign)No CRIS Retention

Element: 2

Automatic Callback Feature List Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

3

No

No

Data Parameters:

1-999

Element: 3

Automatic Callback Feature Name (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

8

No

No

Code Set:

CodeMeaning
*ACBCAutomatic Callback

Symbols:

Asterisk

Element Rules:

Lucent has defined most of the popular assignable service features, which are referred to as “pre-constructed” features and are identified on a FID by a mandatory leading asterisk “*”.  Additionally, system administrators are able to locally customize additional assignable features, which are referred to as “constructible” features.  Constructible features are locally developed, do not contain a leading asterisk and have 1-8 character feature names.  The Feature field is used to define both “pre-constructed” and “constructible” types of features.

Element: 4

Automatic Callback Attribute Name (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

7

9

No

No

Code Set:

CodeMeaning
RGBKTYPRingback Type
RGBKINTVLRingback Interval

Element: 5

Automatic Callback Attribute Value (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic or Numeric

1

2

No

No

Code Set:

CodeMeaning
RGBKTYP Attribute Values
A2 seconds on, 4 seconds off
B0.8 seconds on, 0.4 seconds off, 0.8 seconds on, 4 seconds off
C0.4 seconds on, 0.2 seconds off, 0.4 seconds on, 0.2 seconds off, 0.8 seconds on, 4 seconds off.  (default)
D1 second on, 1 second off, 1 second on, 3 seconds off
P1640 milliseconds on, 360 milliseconds off

Data Parameters:

RGBKINTVL Attribute Values
24, 30, 36, 42, 48

Element Rules:

The switch default for RGBKINTVL is 24.

No.

Element Combination

Series

Separator

1.

1 SP 2 - 3

No

2.

1 SP 2 - 3 SP [ 4 . 5 , SP ]

No

3.

2 - 3

No

4.

2 - 3 SP [ 4 . 5 , SP ]

No


SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Optional

Alphanumeric

0

23

Element: 1

CRIS Retention Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

1

No

No

Code Set:

CodeMeaning
+ (Plus Sign)No CRIS Retention

Element: 2

Automatic Callback Feature List Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

1-999

Element Rules:

When element 2 is used there must be a corresponding LH entry.

Element: 3

Automatic Callback Feature Name (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

8

No

No

Code Set:

CodeMeaning
*ACBCAutomatic Callback

Symbols:

Asterisk

Element Rules:

Lucent has defined most of the popular assignable service features, which are referred to as “pre-constructed” features and are identified on a FID by a mandatory leading asterisk “*”.  Additionally, system administrators are able to locally customize additional assignable features, which are referred to as “constructible” features.  Constructible features are locally developed, do not contain a leading asterisk and have 1-8 character feature names.  The Feature field is used to define both “pre-constructed” and “constructible” types of features.

Element: 4

Automatic Callback Attribute Name (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

7

9

No

No

Code Set:

CodeMeaning
RGBKTYPRingback Type
RGBKINTVLRingback Interval

Element: 5

Automatic Callback Attribute Value (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic or Numeric

1

2

No

No

Code Set:

CodeMeaning
RGBKTYP Attribute Values
A2 seconds on, 4 seconds off
B0.8 seconds on, 0.4 seconds off, 0.8 seconds on, 4 seconds off
C0.4 seconds on, 0.2 seconds off, 0.4 seconds on, 0.2 seconds off, 0.8 seconds on, 4 seconds off.  (default)
D1 second on, 1 second off, 1 second on, 3 seconds off
P1640 milliseconds on, 360 milliseconds off

Data Parameters:

RGBKINTVL Attribute Values
24, 30, 36, 42, 48

Element Rules:

The switch default for RGBKINTVL is 24.

Element: 6

TL1 View Indicator (TL1; FETEX-150)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
TTSPDNCT View

Element: 7

Automatic Callback Attribute Name (TL1; FETEX-150; GTD-5 EAX; SanteraOne; DCO)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

6

Yes

No

Code Set:

CodeMeaning
ACBBAutomatic Callback Billing Records (TL1) (DNCT)
ACBGAutomatic Callback Business Group (BBG) (TL1; FETEX-150; DCO) (Subcriber Lines and DNCT)
ACBISWAutomatic Callback Intraswitch Only (ISDN) (TL1) (DNCT)
ACCLAutomatic Callback - CLASS Feature (FETEX-150; DCO)
FRFlat Rate (CLASS) (TL1; GTD-5 EAX; SanteraOne) (Subscriber Lines and DNCT)
UNRESAutomatic Callback Unrestricted Calls (ISDN) (TL1) (DNCT)
USUsage Sensitive (CLASS) (TL1; GTD-5 EAX) (Subscriber Lines and DNCT)

Element Rules:

In a TL1 switch, code set ACBB is only allowed with code sets ACBG, ACBISW, or UNRES when assigned to a Directory Number.
In a TL1 switch, code sets ACBG, UNRES, and ACBISW are the only valid code sets when the feature is assigned to a specific Directory Number on a terminal, and element 6 is required when these code sets appear.
In the GTD-5 EAX switch, applicable to non - BBG lines or to define a feature included in a CLASS feature package on a centrex line.
In the GTD-5 EAX switch, the switch default for Centrex, Multiline Hunt Group members, COIN lines and Customer Owned Coin Operated Telephones (COCOTS) is OFF.  For all other line types, the switch default is US, but can be overriden by the value shown in the ACBK FID or the Restrict Casual Use (RCU) FID.

Element: 8

ACBB Attribute Value (TL1)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

2

No

No

Code Set:

CodeMeaning
DDetailed
NNone
UGUse The Customer Group Value
USUse The Per Switch Value

Element Rules:

The switch default for DN/CTs that are members of a customer group is UG, use the customer group value.
The switch default for DN/CTs that are not members of a customer group is US, use the per switch value.
The switch default is NONE when ACB is assigned to a specific Directory Number on a terminal or to a Directory Number in a TL1 switch.

Element: 9

Billing Option Attribute Name (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

6

6

No

No

Code Set:

CodeMeaning
BLGOPTBilling Option

Element: 10

Billing Option Attribute Value (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

5

No

No

Code Set:

CodeMeaning
AMAAMA Record Created
NOAMANo AMA Record Created

Element Rules:

Switch default is NOAMA.

Element: 11

Key List Identifier (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

6

6

No

No

Code Set:

CodeMeaning
KEYLSTKey List

Element: 12

Key List Value (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

2

Yes

Yes

Code Set:

CodeMeaning
1-69Key List
$Feature to be associated with all DN Keys

No.

Element Combination

Series

Separator

1.

1 SP 2

No

2.

1 SP 3

No

3.

1 SP 3 SP [ 4 . 5 , SP ]

No

4.

1 SP 6 SP 7

No

5.

1 SP 7

No

6.

1 SP 7 . 8

No

7.

2

No

8.

3

No

9.

3 SP [ 4 . 5 , SP ]

No

10.

6 SP 7

No

11.

7

Yes

, SP

12.

7 . 8

No

13.

9 . 10 , SP 11 . 12

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, E,D, R

I,O, C,T, E,D, R

I,O

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, E,D, M,X, R

I,O, C,T, E,D, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.