ACOS

ADDITIONAL CALL OFFERING SERVICES

INDICATES:

The type of Additional Call Offering service to be provided and the total number of calls which can be supported for this ISDN user over a standard interface.

DATE:

4/14/2005

BILLING:

CRIS and CABS

APPLICATIONS:

5ESS, DMS-100, EWSD, FETEX-150, ISDN BRI, TL1


SECTION - POSITION

EXAMPLES

S&E - FL

5E8
I1   @@S/TN 732 555-1234/DSNA 10.IBZX.123456
     ..NJ/ACOS CSVACO.U, CSVLIMIT.3;
     CSDACO.U, CSDLIMIT.5

                or

I1   @@A/TN 732 555-1234/DSNA 10.IBZX.
     ..NJ/ACOS CSVACO.U, CSVLIMIT.5

5E9
I1   @@S/TN 732 271-1234/DSNA 10.IBZX.123456
     ..NJ/ACOS CSVACO.INTRA,
     CSVLIMIT.4, CSVNBL.3; CSDACO.INCOM,
     CSDLIMIT.4, CSDNBL.3/TGS *TGUUT

TL1, FETEX-150, EWSD
I1   @@A/TN 732 555-1234/DSNA 10.IBZX.
     123456..NJ/PN 555-4343/ACOS
     UNRES, CRBL.3, NBL.2

                 or

TL1
I1   @@J/TN 732 555-1234/DSNA 10.IBZX.
     123456..NJ/PN 555-6767/ACOS
     UNRES, CRBL.4, NBL.3, ACOB.A

DMS-100
I1   @@A/TN 732 555-1234/DSNA 10.IBZX.
     123456..NJ/PN 555-2345/KEY 3 NUMC
     3/ACOS ACOU NBL.2

DMS-100 NI2 (NA008)
I1   @@A/TN 732 555-1234/DSNA 10.IBZX.
     123456..NJ/ACOS CRBL VI.2, CMD.1; DBC
     SPEECH.1, SPEECH.2, 64K.3; ACOU
     VI.1, CMD.1/KEY 1/LTID ISDN 2/LTCL
     BRAFS CS NI2 PS N; PVC VERSION FUNC2

FID RULES/CONSTRAINTS:

  1. DMS-100 NI1
    The KEY FID with NUMC or AFCO data parameters is required on the same logical line as the ACOS FID.  The NUMC data parameters of the KEY FID equate to the Call Reference Busy Limit (CRBL) described in TR-TSY-000857.
  2. DMS-100 NI2 NA008
    The FIDs AFCO and KEY with NUMC data parameters are prohibited on the same logical line as the ACOS FID.
  3. DMS-100 NI1 NA011
    NDNAP specifies the total number of keys a Directory Number is to occupy on an ISDN set.  This feature is dependant on the Call Reference Busy Limit (CRBL) option.  The appearance of NDNAP must be equal to or greater than the total number of the CRBL Attribute VI.  The appearance of NDNAP must be less than or equal to the sum of the CRBL Attributes VI and CMD.
  4. SERIES AND RANGE ENTRIES - PROCESSING
    Service Order Analysis and Control System (SOAC) should process series and range data entries using the DUPLICATE algorithm.
  5. T, F, and X order types prohibited for Access Service application.
  6. X action code prohibited on Access Service orders.

REFERENCES:

  1. TL1
    TR-NWT-000199, DNCT View, Keywords ACO, CRBL, NBL, ACOB.
  2. DMS-100
    Northern Telecom Practice 297-2401-310, option ACOU.
  3. 5ESS
    Lucent Technologies 235-118-257, View 23.2, Keywords CSDACO, CSDLIMIT, CSDNBLIMIT, CSVACO, CSVLIMIT, CSVNBLIMIT.
  4. FETEX-150
    ES11X-1511-H72, Parameter ACO, CRBL, and NBL.
  5. EWSD
    Siemens Stromberg-Carlson 0770-00010, Keywords ACOU, ACOR, ACOIO, ACOIGO, CRBLIM, ACOLIM.
  6. DMS-100 NI2 (NA008)
    Nortel Preliminary Document AF6658, Options CRBL and ACOU.
  7. DMS-100 NI1 (NA011)
    NORTEL Preliminary Document AF7485, Option NDNAP.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

3

55

Element: 1

Additional Call Offering Attribute Name (5E8 or later)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

6

6

No

No

Code Set:

CodeMeaning
CSVACOCircuit Switched Voice Additional Call Offering
CSDACOCircuit Switched Data Additional Call Offering

Element: 2

Additional Call Offering Attribute Value

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

5

No

No

Code Set:

CodeMeaning
UUnrestricted (5E8 or later)
INTRAUnrestricted Intra ISDN Terminal Group (5E9 or later)
INCOMUnrestricted Incoming Only to ISDN Terminal Group (5E9 or later)

Element Rules:

If code sets INTRA or INCOM appear, the terminal group feature is required for the same directory number.

Element: 3

Call Limit Attribute Name (5E8 or later)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

8

8

No

No

Code Set:

CodeMeaning
CSVLIMITCircuit Switched Voice Call Limit
CSDLIMITCircuit Switched Data Call Limit

Element: 4

Call Limit Attribute Value (5E8 or later)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

1-16

Element: 5

Notification Busy Limit Attribute Name (5E9 or later)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

6

6

No

No

Code Set:

CodeMeaning
CSVNBLCircuit Switched Voice Notification Busy Limit
CSDNBLCircuit Switched Data Notification Busy Limit

Element: 6

Notification Busy Limit Attribute Value (5E9 or later)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

0-15

Element Rules:

Element 6 must be less than Call Limit Attribute Value (Element 4).

Element: 7

Additional Call Offering Attribute Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

7

Yes

No

Code Set:

CodeMeaning
RESRestricted (TL1, EWSD)
RSTRRestricted (FETEX-150)
UINCBGUnrestricted Incoming to Basic Business Group Only (TL1, FETEX-150, EWSD)
UITRABGUnrestricted Intra-Basic Business Group Only (TL1, FETEX-150, EWSD)
UNRESUnrestricted (TL1, EWSD)
URSTRUnrestricted (FETEX-150)

Element Rules:

CRBL and NBL are not valid with Packet Mode Data.

Element: 8

Call Reference Busy Limit Attribute Name (TL1, FETEX-150, EWSD)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
CRBLCall Reference Busy Limit

Element: 9

CRBL Attribute Value (TL1, FETEX-150, EWSD)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

1-16

Element Rules:

The switch default is the number of B-Channels subscribed to.

Element: 10

Notification Busy Limit Attribute Name (TL1, FETEX-150, EWSD)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
NBLNotification Busy Limit

Element: 11

NBL Attribute Value (TL1, FETEX-150, EWSD)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

0-15

Element Rules:

The switch default for NBL is 1.
The value for NBL should be less than the value for CRBL.

Element: 12

Additional Call Offering Billing Records (TL1)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
ACOBBilling Records

Element: 13

ACOB Attribute Value (TL1)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

2

No

No

Code Set:

CodeMeaning
AAggregate
NNone
UGUse The Customer Group Value
USUse The Per Switch Value

Element Rules:

The switch default for customer group members is UG, Use Customer Group value.
The switch default for DN/CTs not in a customer group is US, Use Per Switch value.

Element: 14

Additional Call Offering (ACO) Feature Name (DMS-100, NI1)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
ACOUAdditional Call Offering - Unrestricted

Element: 15

ACO Attribute Name (DMS-100, NI1)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
NBLNotification Busy Limit

Element: 16

ACO Attribute Value (DMS-100, NI1)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

0 - 4

Element: 17

Call Reference Busy Limit (CRBL) Feature Name (DMS-100 NI2, NA008)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
CRBLCall Reference Busy Limit

Element: 18

CRBL Attribute Name (DMS-100 NI2, NA008)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

3

No

No

Code Set:

CodeMeaning
VIVoice Call Reference Busy Limit
CMDCircuit Mode Data Call Reference Busy Limit

Element: 19

CRBL Attribute Value (DMS-100 NI2, NA008)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

0-16

Element: 20

Number of Directory Number Appearances (NDNAP) Feature Name (DMS-100 NI2, NA011)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

5

5

No

No

Code Set:

CodeMeaning
NDNAPNumber of Directory Number Appearances

Element: 21

NDNAP Attribute Name (DMS-100 NI2, NA011)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

5

5

No

No

Code Set:

CodeMeaning
NDNAPNumber of Directory Number Appearances

Element: 22

NDNAP Attribute Value (DMS-100 NI2, NA011)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

1-32

Element: 23

Default Bearer Capability (DBC) Feature Name (DMS-100 NI2, NA008)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
DBCDefault Bearer Capability

Element: 24

DBC Key Number Attribute Name (DMS-100 NI2, NA008)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

6

No

No

Code Set:

CodeMeaning
SPEECHSPEECH
31K3.1K
56K56K Circuit Mode Data
64K64K Circuit Mode Data

Element: 25

DBC Key Number Attribute Value (DMS-100 Nl2, NA008)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

1-64

Element: 26

Additional Call Offering (ACO) Feature Name (DMS-100 NI2, NA008)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
ACOUAdditional Call Offering - Unrestricted

Element: 27

ACO Attribute Name (DMS-100 NI2, NA008)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

3

No

No

Code Set:

CodeMeaning
VIVI_NT1_NBL - Voice Notification Busy Limit
CMDCMD_NBL - Circuit Mode Data Notification Busy Limit

Element: 28

ACO Attribute Value (DMS-100 NI2, NA008)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

0-15

No.

Element Combination

Series

Separator

1.

1 . 2

Yes

; SP

2.

1 . 2 , SP 3 . 4

Yes

; SP

3.

1 . 2 , SP 3 . 4 , SP 5 . 6

Yes

; SP

4.

3 . 4

Yes

; SP

5.

7

No

6.

7 , SP 8 . 9

No

7.

7 , SP 8 . 9 , SP 10 . 11

No

8.

7 , SP 8 . 9 , SP 10 . 11 , SP 12 . 13

No

9.

7 , SP 10 . 11

No

10.

7 , SP 10 . 11 , SP 12 . 13

No

11.

7 , SP 12 . 13

No

12.

14 SP 15 . 16

No

13.

17 SP [ 18 . 19 , SP ]

No

14.

17 SP [ 18 . 19 , SP ] ; SP 20 SP 21 . 22

No

15.

17 SP [ 18 . 19 , SP ] ; SP 20 SP 21 . 22 ; SP 23 SP [ 24 . 25 , SP ]

No

16.

17 SP [ 18 . 19 , SP ] ; SP 20 SP 21 . 22 ; SP 23 SP [ 24 . 25 , SP ] ; SP 26 SP [ 27 . 28 , SP ]

No

17.

17 SP [ 18 . 19 , SP ] ; SP 20 SP 21 . 22 ; SP 26 SP [ 27 . 28 , SP ]

No

18.

17 SP [ 18 . 19 , SP ] ; SP 23 SP [ 24 . 25 , SP ]

No

19.

17 SP [ 18 . 19 , SP ] ; SP 23 SP [ 24 . 25 , SP ] ; SP 26 SP [ 27 . 28 , SP ]

No

20.

17 SP [ 18 . 19 , SP ] ; SP 26 SP [ 27 . 28 , SP ]

No

21.

20 SP 21 . 22

No

22.

20 SP 21 . 22 ; SP 23 SP [ 24 . 25 , SP ]

No

23.

20 SP 21 . 22 ; SP 23 SP [ 24 . 25 , SP ] ; SP 26 SP [ 27 . 28 , SP ]

No

24.

20 SP 21 . 22 ; SP 26 SP [ 27 . 28 , SP ]

No

25.

23 SP [ 24 . 25 , SP ]

No

26.

23 SP [ 24 . 25 , SP ] ; SP 26 SP [ 27 . 28 , SP ]

No

27.

26 SP [ 27 . 28 , SP ]

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.