ADAC

ASYNCHRONOUS DEVICE ADAPTER CUSTOMIZATION

INDICATES:

The options and parameters for the customization of an asynchronous device adapter connected to a DAVID-Manager line.

DATE:

10/27/1994

BILLING:

CRIS

APPLICATIONS:

DAVID-Manager


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@3++/ADAC 45-1-1, NAME.SUSIE,
     MODE.HOT TOMMY, PT.2,
     RBR.1200, TBR.1200, AUTO.Y,
     LOG.Y, ACOS.2, FCOS.2, EIA.Y,
     DEV.DTE, DTR.ON, DSRDCD.CONN,
     RC.8

I1   @@3++/ADAC + 45-1-1, NAME.SUSIE,
     MODE.HOT TOMMY, PT.2,
     RBR.1200, TBR.1200, AUTO.Y,
     LOG.Y, ACOS.2, FCOS.2, EIA.Y,
     DEV.DTE, DTR.ON, DSRDCD.CONN,
     RC.8


SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

105

157

Element: 1

CRIS Non-Retention Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

1

No

No

Code Set:

CodeMeaning
+ (plus sign)No CRIS Retention

Element: 2

Port Group Manager Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

2

3

No

No

Data Parameters:

20-255

Element: 3

Port Group Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

3

No

No

Data Parameters:

1-100

Element: 4

Port Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

2

No

No

Data Parameters:

1-40

Element: 5

Name Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
NAME

Element: 6

Name Parameters

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

20

No

No

Data Parameters:

Data characteristics are locally developed.

Element: 7

Data Call Origination Mode Indicator

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
MODE

Element: 8

Data Call Origination Mode Parameters

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

3

4

No

No

Code Set:

CodeMeaning
DIALDialed
DEDDedicated
HOTHot Line
NAILNailed

Element: 9

Data Calling Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

10

No

No

Element: 10

Port Type Indicator

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
PTPort Type

Element: 11

Port Type Parameters

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

2

No

No

Data Parameters:

1-50

Element: 12

Baud Rate Indicators

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
RBRReceive Baud Rate
TBRTransmit Baud Rate

Element: 13

Baud Rate Parameters

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

3

5

No

No

Data Parameters:

300
1200
2400
4800
9600
19200

Element: 14

Autobaud Indicator

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
AUTOAutobaud

Element: 15

Autobaud Parameters

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes - Enable
NNo - Disable

Element: 16

Login Indicator

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
LOGLogin

Element: 17

Login Required Parameter

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

Element: 18

Access Class of Service Indicator

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
ACOSAccess Class of Service

Element: 19

Access Class of Service Parameters

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

3

No

No

Data Parameters:

0-100

Element: 20

Feature Class of Service Indicator

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
FCOSFeature Class of Service

Element: 21

Feature Class of Service Parameters

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

2

No

No

Data Parameters:

0-20

Element: 22

EIA Options Indicator

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
EIA

Element: 23

EIA Options Enable Parameter

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes - Enable
NNo - Disable

Element: 24

Device Type Indicator

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
DEVDevice Type

Element: 25

Device Type Indicators

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
DTEData Terminal Equipment
DCEData Circuit Terminating Equipment

Element: 26

Data Terminal Ready Indicator

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
DTRData Terminal Ready

Element: 27

Data Circuit Terminating Equipment/Data Terminal Ready (DCE/DTR) Parameters

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
ONOn
HSHandshake

Element Rules:

Required when Element 24 code set DEV with Element 25 code set DCE is present.

Element: 28

Data Set Ready/Data Carrier Detect Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

6

6

No

No

Code Set:

CodeMeaning
DSRDCDData Set Ready

Element: 29

Data Circuit Terminating Equipment - Data Set Ready/Data Carrier Detect (DCE-DSR/DCD) Parameters

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

3

No

No

Code Set:

CodeMeaning
ONOn
OFFOff

Element Rules:

Required when Element 24 code set DEV with Element 25 code set DCE is present.

Element: 30

Data Terminal Equipment/Data Terminal Ready (DTE/DTR) Parameters

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

3

No

No

Code Set:

CodeMeaning
ONOn
OFFOff

Element Rules:

Required when Element 24 code set DEV with Element 25 code set DTE is present.

Element: 31

Data Terminal Equipment - Data Set Ready/Data Carrier Detect (DTE-DSR/DCD) Parameters

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

4

No

No

Code Set:

CodeMeaning
ONOn
CONNConnection

Element Rules:

Required when Element 24 Code set DEV and Element 25 code set of DTE are present.

Element: 32

Data Terminal Equipment (DTE) Ring Cycle Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
RCRing Cycle

Element: 33

Data Terminal Equipment (DTE) Ring Cycle Parameters

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

1-8

Element Rules:

Required when Element 24 code set DEV and Element 25 code set of DTE are present.

No.

Element Combination

Series

Separator

1.

1 SP 2 - 3 - 4 , SP 5 . 6 , SP 7 . 8 SP 9 , SP 10 . 11 , SP [ 12 . 13 , SP ] , SP 14 . 15 , SP 16 . 17 , SP 18 . 19 , SP 20 . 21 , SP 22 . 23 , SP 24 . 25 , SP 26 . 27 , SP 28 . 29

No

2.

1 SP 2 - 3 - 4 , SP 5 . 6 , SP 7 . 8 SP 9 , SP 10 . 11 , SP [ 12 . 13 , SP ] , SP 14 . 15 , SP 16 . 17 , SP 18 . 19 , SP 20 . 21 , SP 22 . 23 , SP 24 . 25 , SP 26 . 30 , SP 28 . 31 , SP 32 . 33

No

3.

1 SP 2 - 3 - 4 , SP 5 . 6 , SP 7 . 8 , SP 10 . 11 , SP [ 12 . 13 , SP ] , SP 14 . 15 , SP 16 . 17 , SP 18 . 19 , SP 20 . 21 , SP 22 . 23 , SP 24 . 25 , SP 26 . 27 , SP 28 . 29

No

4.

1 SP 2 - 3 - 4 , SP 5 . 6 , SP 7 . 8 , SP 10 . 11 , SP [ 12 . 13 , SP ] , SP 14 . 15 , SP 16 . 17 , SP 18 . 19 , SP 20 . 21 , SP 22 . 23 , SP 24 . 25 , SP 26 . 30 , SP 28 . 31 , SP 32 . 33

No

5.

2 - 3 - 4 , SP 5 . 6 , SP 7 . 8 SP 9 , SP 10 . 11 , SP [ 12 . 13 , SP ] , SP 14 . 15 , SP 16 . 17 , SP 18 . 19 , SP 20 . 21 , SP 22 . 23 , SP 24 . 25 , SP 26 . 27 , SP 28 . 29

No

6.

2 - 3 - 4 , SP 5 . 6 , SP 7 . 8 SP 9 , SP 10 . 11 , SP [ 12 . 13 , SP ] , SP 14 . 15 , SP 16 . 17 , SP 18 . 19 , SP 20 . 21 , SP 22 . 23 , SP 24 . 25 , SP 26 . 30 , SP 28 . 31 , SP 32 . 33

No

7.

2 - 3 - 4 , SP 5 . 6 , SP 7 . 8 , SP 10 . 11 , SP [ 12 . 13 , SP ] , SP 14 . 15 , SP 16 . 17 , SP 18 . 19 , SP 20 . 21 , SP 22 . 23 , SP 24 . 25 , SP 26 . 27 , SP 28 . 29

No

8.

2 - 3 - 4 , SP 5 . 6 , SP 7 . 8 , SP 10 . 11 , SP [ 12 . 13 , SP ] , SP 14 . 15 , SP 16 . 17 , SP 18 . 19 , SP 20 . 21 , SP 22 . 23 , SP 24 . 25 , SP 26 . 30 , SP 28 . 31 , SP 32 . 33

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, X,R, M

I,O, C,T, D,E, X,R, M

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.