ADRO

ADD DISCONNECT RELATED ORDER

INDICATES:

The service order type and number of a related service order entered as a cross-reference when reusing facilities and/or equipment on designed services.

DATE:

10/31/2014

BILLING:

CRIS and CABS

APPLICATIONS:

General Purpose


SECTION - POSITION

EXAMPLES

IDENT - LH

ADRO C123456789

FID RULES/CONSTRAINTS:

  1. Section: IDENT   Position: LH
    The absence of an action code infers the presence of an "I" (IN) action code.   The I action code is optional on the service order. 

  2. T and F order types prohibited for Access Service application.
  3. At the time of issuance, this FID was not supported by all Telcordia and/or Ericsson Operations Support Systems (OSSs).  Please check with your local OSS staff for processing capabilities (current and/or proposed) for the specific OSS.

SERVICE ORDER ACTIVITY NOTES:

  1. The ADRO FID is used with the RFF FID to link outward (disconnect) and inward (add) orders, for designed services, so that the orders may be worked together.
  2. The ADRO FID is for reuse on TIRKS inventoried facilities; RRSO is for reuse of the FACS interfaces (all SOAC interfaces except TIRKS).
  3. The FID RFF is required in the S&E section when there is more than one circuit on the order.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

IDENT - LH

Required

Alphanumeric

4

12

Element: 1

Service Order Type

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
TTo order for change of address
FFrom order for change of address
CChange
NNew Connect
DComplete Disconnect

Element: 2

Service Order Number

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

3

11

No

No

No.

Element Combination

Series

Separator

1.

1  2

19

, SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: IDENT - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

P

P

P

P

Action Codes

I

I

I

I

I

-

-

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.