ADS

ADDRESS SIGNALING

INDICATES:

The optional Address Signaling features for an entry switch transmission path group on Feature Group B or Feature Group C Access Service, and Cellular Mobile Carrier Service.

DATE:

9/21/1989

BILLING:

CRIS and CABS

APPLICATIONS:

Access Service, Wireless


SECTION - POSITION

EXAMPLES

S&E - FL

IG1  TSC AE123456/NC SD-B/TTC SO
     /ADS RP

              or

I1   @@A/TN 555-4221/ADS DP

FID RULES/CONSTRAINTS:

  1. T, F, and X order types prohibited for Access Service application.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphabetic

2

3

Element: 1

Revertive Pulse Address Signaling

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
RPRevertive Pulse Address Signaling

Element Rules:

Required when ordered as Common Switching option.
Available on Feature Group C only.

Element: 2

Dial Pulse Address Signaling

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
DPDial Pulse Address Signaling

Element Rules:

Required when ordered as Common Switching option.
Available on Feature Group C and Cellular Mobile Carrier.

Element: 3

Panel Call Indicator Address Signaling

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
PCIPanel Call Indicator Address Signaling

Element Rules:

Required when ordered as Common Switching option.
Available on Feature Group C only.

Element: 4

Immediate Dial Pulse Address Signaling

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
IDPImmediate Dial Pulse Address Signaling

Element Rules:

Required when ordered as Common Switching option.
Available on Feature Group C and Cellular Mobile Carrier.

Element: 5

Wink Start

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
WKWink Start

Element Rules:

Available on Feature Group B and C service.

No.

Element Combination

Series

Separator

1.

1

No

2.

2

No

3.

3

No

4.

4

No

5.

5

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I

I

O

O

I,O, C,T, D,E, R

I,O, C,T, D,E, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.