AHM

ACCESS SERVICE HOURS AND MINUTES

INDICATES:

The number of technicians and the amount of regular, overtime and/or premium time to be charged for additional labor or engineering on Access Service.

DATE:

4/24/2008

BILLING:

CRIS and CABS

APPLICATIONS:

Access Service, Billing


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@V/TN 732 555-1234/AHM 3N 7H 30M,
     2X 1H, 1P 1H

FID RULES/CONSTRAINTS:

  1. Restricted to Access Service Tariff application only.
  2. T, F, and X order types prohibited for Access Service application.
  3. X action code prohibited on Access Service application.

SERVICE ORDER ACTIVITY NOTES:

  1. The AHM FID and data are required on the Uniform Service Order Code (USOC) logical line on all orders with USOCs for additional engineering and labor charges, and maintenance of service charges.  See BR- 751-000-155, The USOC Manual, or the COMMON LANGUAGE Products eCoder System.
  2. The AHM FID will indicate aggregate hours and minutes per group of test USOCs having the same rate.  Accordingly, AHM is required to be specified only with the first test USOC of a group of equally rated USOCs, but will be followed by the total time to be charged for additional labor for the entire group of USOCs. The applicable testing USOCs are for non-scheduled cooperative and manual testing, and cooperative acceptance testing.  See BR-751-000-155, The USOC Manual, or the COMMON LANGUAGE Products eCoder System.
  3. CRIS Application
    The AHM FID and data identify the number of technicians and time to be charged for additional labor or engineering on an Access Service billed in CRIS.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

4

18

Element: 1

Number of Technicians

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

1-9

Element Rules:

Required to indicate the number of technicians for additional labor or engineering.  The element is not required when AHM FID is used for Billing and Collection application.

Element: 2

Type of Working Hours Indicator

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
NNormal Working Hours
XOvertime
PPremium Time

Element Rules:

Code Set P is prohibited with additional engineering charge USOC.
Code Set N is prohibited with with additional labor - Installation and Repair USOC.
Code Set X is prohibited with any Billing and Collection application.

Element: 3

Number of Hours

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

2

4

No

No

Data Parameters:

1H-999H

Element Rules:

Required when time is one hour or greater.

Element: 4

Number of Minutes

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

2

3

No

No

Data Parameters:

1M-59M

Element Rules:

Required when time is less than one hour.
Element prohibited with any Billing and Collection application.

Element: 5

Unregulated Time Sensitive Charges For Inside Wire

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

4

No

No

Data Parameters:

Data characteristics are locally developed.

Element: 6

Work Type Identifier

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Data Parameters:

Data characteristics are locally developed.

Element Rules:

Element 6 required when element 5 is used.

No.

Element Combination

Series

Separator

1.

1  2 SP 3

Yes

, SP

2.

1  2 SP 3 SP 4

Yes

, SP

3.

1  2 SP 3 SP 4 SP 5 SP 6

Yes

, SP

4.

1  2 SP 3 SP 4 SP 6

Yes

, SP

5.

1  2 SP 3 SP 5 SP 6

Yes

, SP

6.

1  2 SP 3 SP 6

Yes

, SP

7.

1  2 SP 4

Yes

, SP

8.

1  2 SP 4 SP 5 SP 6

Yes

, SP

9.

1  2 SP 4 SP 6

Yes

, SP

10.

2 SP 3

Yes

, SP

11.

2 SP 3 SP 4

Yes

, SP

12.

2 SP 3 SP 4 SP 5 SP 6

Yes

, SP

13.

2 SP 3 SP 5 SP 6

Yes

, SP

14.

2 SP 4

Yes

, SP

15.

2 SP 4 SP 5 SP 6

Yes

, SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I, E

I, E

O, D

I

I, O, C, T, D, E, R, M, X

I, O, C, T, D, E, R, M, X

I, O, C, T, R

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.