AID

AUTOMATIC IDENTIFIED OUTWARD DIALING

INDICATES:

The AIOD (Automatic Identified Outward Dialing) Trunk Number (Talking Path) index assigned to a PBX or Centrex-CU Trunk.  It is used with a PBX or Centrex station number to indicate that the AIOD feature is applicable.

DATE:

4/28/2005

BILLING:

CRIS

APPLICATIONS:

1AESS, Centrex, Private Branch Exchange Service (PBX), TL1


SECTION - POSITION

EXAMPLES

S&E - FL

Install 4 trunks with AID capability on "Trunk Side" of 1AESS Office with stations equipped for both DID and AIOD
TN 732 222-3000  (Identification Section)
---S&E
G1   TLI 3200/PSM .AINT
I1   @@A/OGO 1
     /STN 421-3231;02-320-014
     /AID 34/DBN 3200
I3   @@A/OGO 2-4/AID 35-37

Install 1 combination trunk for provisioning purposes and 5 AIOD trunks on "Line Side" of a 1AESS Office
equipped for AIOD only

TN 732 345-8000  (Identification Section)
---S&E
G1   HML 22/TLI 8500/PSM .AINT
I1   @@A/TER 1/WRP/DBN 8500/PSM .TKNT
     /STN 345-8500;02-321-015
I5   @@A/TER 3001-3005/AID 66-70
G1
IHML 22-TER H1 N3001-3005
     /HTY RG/TLI 8500

Install a PBX station line with AIOD
I1   @@A/TN 4567/AID

TL1
I1   @@A/TN 732 555-1234/AID

FID RULES/CONSTRAINTS:

  1. Data entry is required with trunks having AIOD capability.
  2. The presence of the AID FID implies a "yes" value in the TL1 translations.
  3. In a TL1 switch, this FID is not valid for an analog member of an EKTS.
  4. SERIES AND RANGE ENTRIES - PROCESSING
    Service Order Analysis and Control System (SOAC) should process series and range data entries using the DISTRIBUTE algorithm.

REFERENCES:

  1. TL1
    TR-NWT-000199, DNCT View, Keyword AIOD.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Optional

Numeric

0

4

Element: 1

Automatic Identified Outward Dialing

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

Yes

Yes

Data Parameters:

1-2000

ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.