ATH |
AUTHORIZATION CODE |
INDICATES: |
The Authorization Code feature name and optional feature attributes to be assigned to a line in a Stored Program Controlled Switch. |
DATE: |
3/2/2006 |
BILLING: |
CRIS |
APPLICATIONS: |
5ESS, DMS-100, EWSD |
SECTION - POSITION |
EXAMPLES |
S&E - LH |
|
IATH 220-*ATHACF ATHGRP.A234567, |
|
S&E - FL |
|
5ESS |
SERVICE ORDER ACTIVITY NOTES: |
|
REFERENCES: |
|
SECTION - POSITION |
APPEARANCE |
MODE |
MIN |
MAX |
S&E - LH |
Required |
Alphanumeric |
3 |
44 |
Element: 1 |
Authorization Code Feature Group Number (5ESS, DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Required |
Numeric |
1 |
3 |
No |
No |
Data Parameters: |
||
|
Element: 2 |
Authorization Code Feature Name (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
8 |
No |
No |
Element: 3 |
Authorization Code Attribute (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
6 |
12 |
Yes |
No |
Symbols: |
Hyphen |
Element Rules: |
The data entry is comprised of a one (1) to seven (7) numeric security code plus hyphen and four (4) alpha characters describing the option. |
Element: 4 |
Authorization Code Feature Name (5ESS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
8 |
No |
No |
Code Set: |
||||||
|
Symbols: |
Asterisk |
Element Rules: |
Lucent has defined most of the popular assignable service features, which are referred to as “pre-constructed” features and are identified on a FID by a mandatory leading asterisk “*”. Additionally, system administrators are able to locally customize additional assignable features, which are referred to as “constructible” features. Constructible features are locally developed, do not contain a leading asterisk and have 1-8 character feature names. The Feature field is used to define both “pre-constructed” and “constructible” types of features. |
Element: 5 |
Authorization Code Attribute Name (5ESS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
6 |
9 |
No |
No |
Code Set: |
||||||||||||
|
Element: 6 |
ATHGRP and CSDATHGRP Attribute Values |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
8 |
No |
No |
Data Parameters: |
||||
|
Element: 7 |
ATHFIRST, ATHFORAMA and ATHFORMDR Attribute Values |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
1 |
No |
No |
Code Set: |
||||||
|
No. |
Element Combination |
Series |
Separator |
1. |
1 - 2 |
No |
|
2. |
1 - 2 SP 3 |
No |
|
3. |
1 - 4 SP [ 5 . 6 , SP ] |
No |
|
4. |
1 - 4 SP [ 5 . 6 , SP ] , SP [ 5 . 7 , SP ] |
No |
|
5. |
1 - 4 SP [ 5 . 7 , SP ] |
No |
SECTION - POSITION |
APPEARANCE |
MODE |
MIN |
MAX |
S&E - FL |
Required |
Alphanumeric |
1 |
40 |
Element: 1 |
Authorization Code Feature Group Number (5ESS, DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
3 |
No |
No |
Data Parameters: |
||
|
Element Rules: |
When element 1 is used, there must be a corresponding LH entry. |
Element: 2 |
Authorization Code Feature Name (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
8 |
No |
No |
Element: 3 |
Authorization Code Attribute (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
6 |
12 |
Yes |
No |
Symbols: |
Hyphen |
Element Rules: |
The data entry is comprised of a one (1) to seven (7) numeric security code plus hyphen and four (4) alpha characters describing the option. |
Element: 4 |
Station Specific Authorization Code (SSAC) (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
12 |
10 |
No |
Data Parameters: |
||
|
Element: 5 |
Authorization Code Feature Name (EWSD, APS 16.0) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
7 |
7 |
No |
No |
Element: 6 |
Authorization Code Feature Name (5ESS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
8 |
No |
No |
Code Set: |
||||||
|
Symbols: |
Asterisk |
Element Rules: |
Lucent has defined most of the popular assignable service features, which are referred to as “pre-constructed” features and are identified on a FID by a mandatory leading asterisk “*”. Additionally, system administrators are able to locally customize additional assignable features, which are referred to as “constructible” features. Constructible features are locally developed, do not contain a leading asterisk and have 1-8 character feature names. The Feature field is used to define both “pre-constructed” and “constructible” types of features. |
Element: 7 |
Authorization Code Attribute Name (5ESS) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
6 |
9 |
No |
No |
Code Set: |
||||||||||||
|
Element: 8 |
ATHGRP and CSDATHGRP Attribute Values |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
8 |
No |
No |
Data Parameters: |
||||
|
Element: 9 |
ATHFIRST, ATHFORAMA and ATHFORMDR Attribute Values |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
1 |
No |
No |
Code Set: |
||||||
|
No. |
Element Combination |
Series |
Separator |
1. |
1 |
No |
|
2. |
2 |
No |
|
3. |
2 SP 3 |
No |
|
4. |
2 SP 4 |
No |
|
5. |
5 |
No |
|
6. |
6 |
No |
|
7. |
6 SP [ 7 . 8 , SP ] |
No |
|
8. |
6 SP [ 7 . 8 , SP ] , SP [ 7 . 9 , SP ] |
No |
|
9. |
6 SP [ 7 . 9 , SP ] |
No |
ORDER TYPE/ACTION CODE/FID RELATIONSHIPS |
Order Section - Position: S&E - LH
|
Order Type |
N |
T |
F |
D |
C |
R |
X |
P |
A |
Presence |
O |
O |
O |
O |
O |
O |
O |
P |
P |
Action Codes |
I,E |
I,E |
O,D |
O,D |
I,O, C,T, E,D, R |
I,O, C,T, E,D, R |
I,O |
- |
- |
CRIS |
CABS |
|
Data Retention |
Yes |
No |
Printed on CSR |
Yes |
No |
Order Section - Position: S&E - FL
|
Order Type |
N |
T |
F |
D |
C |
R |
X |
P |
A |
Presence |
O |
O |
O |
O |
O |
O |
O |
P |
P |
Action Codes |
I,E |
I,E |
O,D |
O,D |
I,O, C,T, E,D, M,X, R |
I,O, C,T, E,D, M,X, R |
I,O, C,T, R |
- |
- |
CRIS |
CABS |
|
Data Retention |
Yes |
No |
Printed on CSR |
Yes |
No |
Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure. |
iconectiv Confidential - Restricted Access This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv. |
Licensed Material - Property of iconectiv Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv. |