BAAD |
BAND ADVANCE |
|
INDICATES: |
Automatic overflow of terminating calls to another Access Service WATS Access Line (WAL) group when the first group has exceeded its call capacity. |
|
DATE: |
10/31/2014 |
|
BILLING: |
CABS |
|
APPLICATIONS: |
800 Service, Access Service, Access Service Request (ASR), Hunting |
|
SECTION - POSITION |
EXAMPLES |
|
S&E - FL |
|
|
IHML 10-TER H1-10/HTY RG/TLI |
|
FID RULES/CONSTRAINTS: |
|
|
SERVICE ORDER ACTIVITY NOTES: |
|
|
REFERENCES: |
|
|
SECTION - POSITION |
APPEARANCE |
MODE |
MIN |
MAX |
|
S&E - FL |
Required |
Alphanumeric |
1 |
34 |
|
Element: 1 |
Advance From - Band |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Optional |
Alphabetic or Numeric |
1 |
2 |
No |
No |
|
Data Parameters: |
||||
|
||||
|
Element: 2 |
Advance From - Simulated Facilities Group Number |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Optional |
Numeric |
1 |
4 |
No |
No |
|
Data Parameters: |
||
|
||
|
Element Rules: |
|
Required when Simulated Facilities Group overflow is used to effect band advance. |
|
Element: 3 |
Advance To - Band |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Optional |
Alphabetic or Numeric |
1 |
2 |
No |
No |
|
Data Parameters: |
||||
|
||||
|
Element: 4 |
Advance To - Simulated Facilities Group Number |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Optional |
Numeric |
1 |
4 |
No |
No |
|
Data Parameters: |
||
|
||
|
Element Rules: |
|
Required when Simulated Facilities Group overflow is used to effect band advance. |
|
Element: 5 |
Central Office Code (DMS-100 Non-Centrex) |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Optional |
Numeric |
3 |
3 |
No |
No |
|
Reference: |
|
See iconectiv LERG Routing Guide for complete list. |
|
Element: 6 |
Line Number (DMS-100 Non-Centrex) |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Optional |
Numeric |
4 |
4 |
No |
No |
|
Data Parameters: |
||
|
||
|
No. |
Element Combination |
Series |
Separator |
|
1. |
1 |
Yes |
; SP |
|
2. |
1 - 2 , SP 3 - 4 |
Yes |
; SP |
|
3. |
1 - 2 , SP 3 - 4 , SP 3 - 4 |
No |
|
|
4. |
1 - 2 , SP 3 - 4 - 4 |
No |
|
|
5. |
1 - 2 - 4 |
Yes |
; SP |
|
6. |
1 - 2 - 4 , SP 3 - 4 |
No |
|
|
7. |
1 - 2 - 4 - 4 |
No |
|
|
8. |
1 , SP 3 |
Yes |
; SP |
|
9. |
1 - 5 6 , SP 3 - 5 6 |
Yes |
; SP |
|
10. |
1 - 5 6 , SP 3 - 5 6 , SP 3 - 5 6 |
No |
|
|
11. |
1 - 5 6 , SP 3 - 5 6 - 5 6 |
No |
|
|
12. |
1 - 5 6 - 5 6 |
Yes |
; SP |
|
13. |
1 - 5 6 - 5 6 , SP 3 - 5 6 |
No |
|
|
14. |
1 - 5 6 - 5 6 - 5 6 |
No |
|
|
15. |
2 , SP 3 - 4 |
Yes |
; SP |
|
16. |
2 , SP 3 - 4 , SP 3 - 4 |
No |
|
|
17. |
2 , SP 3 - 4 - 4 |
No |
|
|
18. |
2 - 4 |
Yes |
; SP |
|
19. |
2 - 4 , SP 3 - 4 |
No |
|
|
20. |
2 - 4 - 4 |
No |
|
|
21. |
3 |
Yes |
; SP |
|
22. |
5 6 , SP 3 - 5 6 |
Yes |
; SP |
|
23. |
5 6 , SP 3 - 5 6 , SP 3 - 5 6 |
No |
|
|
24. |
5 6 , SP 3 - 5 6 - 5 6 |
No |
|
|
25. |
5 6 - 5 6 |
Yes |
; SP |
|
26. |
5 6 - 5 6 , SP 3 - 5 6 |
No |
|
|
27. |
5 6 - 5 6 - 5 6 |
No |
|
ORDER TYPE/ACTION CODE/FID RELATIONSHIPS |
|
Order Section - Position: S&E - FL
|
|
Order Type |
N |
T |
F |
D |
C |
R |
X |
P |
A |
|
Presence |
O |
P |
P |
O |
O |
O |
P |
P |
P |
|
Action Codes |
I |
- |
- |
O |
I,O, C,T |
I,O, C,T |
- |
- |
- |
|
Other FIDs Required Same Section |
BAND |
- |
- |
BAND |
BAND |
BAND |
- |
- |
- |
|
CRIS |
CABS |
|
|
Data Retention |
No |
Yes |
|
Printed on CSR |
No |
Yes |
|
Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure. |
|
iconectiv Confidential - Restricted Access This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv. |
|
Licensed Material - Property of iconectiv Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv. |