BCGP

BULK CALLING LINE IDENTIFICATION (BCLID) USER GROUP

INDICATES:

The user group name, group attributes and attribute values for the Bulk Calling Line Identification feature in a 5ESS switch.

DATE:

10/13/2005

BILLING:

CRIS

APPLICATIONS:

5ESS, ISDN BRI


SECTION - POSITION

EXAMPLES

S&E - LH

IBCGP|1-BULKGP01 BCID.65535, APID.255

SERVICE ORDER ACTIVITY NOTES:

  1. The BCGP FID is used to define a Bulk Calling Line Identification (BCLID) Group and its associated group attributes via 5ESS View 4.62. Historically, translation work to establish groups has generally been done outside of the service order arena.  By contrast, the Bulk Calling Line Identification Group Identifier (BGI) FID is used to assign a specific BCLID feature to a line and to specify its associated BCLID group name.

REFERENCES:

  1. 5ESS
    Lucent Technologies,  235-118-257, View 4.62, Keywords BCLIDGRP, BCID and APSITEID.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - LH

Required

Alphanumeric

10

23

Element: 1

BCLID Group Attributes Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

3

No

No

Data Parameters:

1-999

Element: 2

BCLID Group Name

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

1

8

No

No

Data Parameters:

Data characteristics are locally developed.

Element: 3

BCLID Attribute Name

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

4

4

Yes

No

Code Set:

CodeMeaning
APIDApplication Processor (AP) Site Identification
BCIDBusiness Customer Identification

Element: 4

BCLID Attribute Value

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

5

No

No

Data Parameters:

0-65535BCID Only
1-255APID Only

No.

Element Combination

Series

Separator

1.

1 - 2 SP [ 3 . 4 , SP ]

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I

I

O

O

I,O, C,T

I,O, C,T

I,O

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.