BGI

BULK CALLING LINE IDENTIFICATION GROUP IDENTIFIER

INDICATES:

The multiline hunt group, Centrex group or PBX DID (Direct Inward Dialing) trunk group is equipped with the Bulk Calling Line Identification (BCLID) feature.

DATE:

6/23/2005

BILLING:

CRIS and CABS

APPLICATIONS:

1AESS, 5ESS, Access Service, DMS-100, ISDN BRI, Open Network Architecture, Voice Messaging


SECTION - POSITION

EXAMPLES

S&E - FL

Multiline Hunt Group
IHML 21-TER H1-7/HTY RG
     /TLI 555-4000
     /BGI 50, BID FR/IOC 32

DID Trunk Group Line
I1   @@A/TN 732 555-1234/TGP 14
     /BGI BID BI/IOC 24

Centrex Group
I1   @@A/732 555-1234/BGI BID FR
     /CTX 10/IOC 45

5ESS - Multiline Hunt Group
IHML 210-TER 1-4/HTY *MHR/BGI
     BMLHG.14

5ESS - Centrex Station, Usage Sensitive, Date Included, Intra-group Recorded
I1   @@A/TN 732 555-1234/BGI *BCUDTIG
     BCLGRP.STAFF

5ESS - Basic Rate ISDN, Flat Rate, Date Not Included, Intra-group Recorded
I1   @@A/TN 732 555-1234/DSNA 10.IBZX.
     123456..NJ/BGI *BCDTIG BCLGRP.
     HOTLINE

FID RULES/CONSTRAINTS:

  1. 1AESS, DMS-100
    When feature is provided on a multiline hunt group, the FID is entered on the left hand Hunting - Multiline Group Number (HML) logical line.
  2. 5ESS
    When feature is provided on a multiline hunt group, the FID with feature name (Element 3) and optional feature attribute name and value (Elements 4 and 5) is entered on the TER 1 assignable USOC logical line, or feature USOC logical line that is associated with TER 1.  Elements 6 and 7 are used only when FID is entered on left hand HML logical line.
  3. The Input-Output Channel (IOC) FID is required on the BGI FID logical line for the 1AESS switch.
  4. T, F, and X order types prohibited for Access Service application.
  5. X action code prohibited on Access Service orders.

REFERENCES:

  1. 1AESS
    AT&T 231-390-243, Addendum - Issue 1, December 1987.
  2. DMS-100
    NORTEL  297-2101-808, Option BCLID.
  3. 5ESS
    Lucent Technologies 235-118-257, Views 1.8, 3.5, 5.1, and 23.8, Keywords BCLIDGRP, BCLIDMLHGGRP.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

1

24

Element: 1

BCLID Group Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

0-641AESS
0-2047DMS-100

Element Rules:

Element is required when feature is assigned to an HML group.

Element: 2

BCLID Usage Sensitive Billing Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

6

6

No

No

Code Set:

CodeMeaning
BID FRFlat Rate
BID BIUsage Sensitive

Symbols:

Space

Element: 3

BCLID Feature Name (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

8

No

No

Code Set:

CodeMeaning
*BCFlat-Rate Billing, Without Date, No Intergroup ID
*BCDTFlat-Rate Billing, With Date, No Intergroup ID
*BCDTIGFlat-Rate Billing, With Date, Intergroup ID
*BCIGFlat-Rate Billing, Without Date, Intergroup ID
*BCUUsage Sensitive Billing, Without Date, No Intergroup ID
*BCUDTUsage Sensitive Billing, With Date, No Intergroup ID
*BCUDTIGUsage Sensitive Billing, With Date, Intergroup ID
*BCUIGUsage Sensitive Billing, Without Date, No Intergroup ID

Symbols:

Asterisk

Element Rules:

Lucent has defined most of the popular assignable service features, which are referred to as “pre-constructed” features and are identified on a FID by a mandatory leading asterisk “*”.  Additionally, system administrators are able to locally customize additional assignable features, which are referred to as “constructible” features.  Constructible features are locally developed, do not contain a leading asterisk and have 1-8 character feature names.  The Feature field is used to define both “pre-constructed” and “constructible” types of features.

Element: 4

BCLID Feature Attribute Name (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

6

6

No

No

Code Set:

CodeMeaning
BCLGRPBCLID Group Name

Element: 5

BCLID Feature Attribute Value (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

8

No

No

Element: 6

BCLID Multiline Hunt Group Identification Attribute Name (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

5

5

No

No

Code Set:

CodeMeaning
BMLHGBCLID Multiline Hunt Group

Element: 7

BCLID Multiline Hunt Group Identification Attribute Value (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

0-99

No.

Element Combination

Series

Separator

1.

1

No

2.

1 , SP 2

No

3.

2

No

4.

3

No

5.

3 SP 4 . 5

No

6.

6 . 7

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, X,R

I,O, C,T, D,E, X,R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.