CFDO

CALL FORWARDING - DO NOT ANSWER OPTIONS

INDICATES:

For the Call Forwarding Do Not Answer Line, the screening class of service, the number of calls that may be forwarded simultaneously and the time period in which they may be forwarded.

DATE:

2/26/2009

BILLING:

CRIS

APPLICATIONS:

Centrex, CS2000, DMS-100, ISDN BRI


SECTION - POSITION

EXAMPLES

S&E - FL

DMS-100 (Prior to BCS 37)
I1   @@A/TN 732 555-1234/CFND N
     732 555-2345/CFDO NSCR 415 30


DMS-100 (BCS 37)
I1   @@A/TN 732 555-1234/CFND N
     732 555-2345/CFDO NSCR 410
     30 PRGRING

CS2000 (SN07)
I1   @@A/TN 732 555-1234/CFND N
     732 555-2345/CFDO NSCR 410
     30 PRGRING

FID RULES/CONSTRAINTS:

  1. ISDN Circuit Switched Bearer Service
    Section:  S&E      Position:  FL

    For mechanized flow-through, FID may be entered on the  FEATURE  USOC logical line if one of the following combinations of FIDs appear on the same logical line:
         -Primary Number (PN) and Call Appearance (CAPP) (with the CA attribute)
         -PN and Key Designation (KEY)
         -Telephone Number (TN) and Service Profile Identifier (SPID)
         -Telephone Line Identifier (TLI), PN and Terminal Number-Multiline Group (TER)

REFERENCES:

  1. NORTEL Practice 297-2101-310, option CFDA, CFDVT
  2. CS2000 (SN07)
    NORTEL Practice 297-8021-808, option CFDVT

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

2

24

Element: 1

Screening Class of Service Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

8

No

No

Data Parameters:

Data characteristics are locally developed.

Element: 2

Number of Calls

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1 - 1024

Element: 3

Time Period

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

2

2

No

No

Code Set:

CodeMeaning
12 - 60Number of Seconds

Element: 4

Ring Control Indicator (DMS-100 BCS 37, CS2000 SN07)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

7

7

No

No

Code Set:

CodeMeaning
FIXRINGCFDA Ringing fixed time-out is provided
PRGRINGSubscriber is able to program the ringing time-out

No.

Element Combination

Series

Separator

1.

1 SP 2 SP 3

No

2.

1 SP 2 SP 3 SP 4

No

3.

3

No

4.

3 SP 4

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-

Other FIDs Required Logical Line

CFND

CFND

CFND

CFND

CFND

CFND

CFND

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.