CFSO

CALL FORWARDING (CF) SIMULTANEOUS/SCREENING OPTIONS

INDICATES:

The subscriber's line is equipped with the Call Forwarding Simultaneous/Screening option.

DATE:

5/9/1996

BILLING:

CRIS and CABS

APPLICATIONS:

DMS-100


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@A/TN 555-7654/CFSO SIM Y,
     NCFU 10, NCFB 2, NCFD 2,
     SCRN Y, NCOS 115/CFNB 555-1234
     /CFND 555-7113

              or

I1   @@A/TN 555-7654/CFNB 555-1234
     /CFND 555-7113/CFSO SIM N,
     SCRN Y, NCOS 115

FID RULES/CONSTRAINTS:

  1. T, F, and X order types prohibited for Access Service Application.
  2. X action code prohibited on Access Service orders.

REFERENCES:

  1. Northern Telecom Practice 297-2101-808, option CFS.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

5

57

Element: 1

Option Indicator

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

3

4

No

No

Code Set:

CodeMeaning
SIMSimultaneous Calls
NCFUNumber of Calls to be Forwarded Through a CFU, CFI or CFF Base Station
NCFBNumber of Calls to be Forwarded Through a CFB Base Station
NCFDNumber of Calls to be Forwarded Through a CFD Base Station
SCRNCall Forward Screen Capability
NCOSNetwork Class of Service (Customer Access Treatment Code)

Element Rules:

Code sets NCFU, NCFB and NCFD are required when code set SIM has a data entry of Y.

Element: 2

CF Simultaneous and Screen Capability Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

Element: 3

Maximum Number of Concurrent CF Calls

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1 - 1024

Element Rules:

Element required when code set NCFU is used on element 1.

Element: 4

Maximum Number of Concurrent CFB Calls

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1 - 1024

Element Rules:

Element required when code set NCFB is used on element 1.

Element: 5

Maximum Number of Concurrent CFD Calls

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1 - 1024

Element Rules:

Element required when code set NCFD is used on element 1.

Element: 6

CF NCOS

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

0 - 255

No.

Element Combination

Series

Separator

1.

1 SP 2

Yes

, SP

2.

1 SP 2 , SP 1 SP 3 , SP 1 SP 4 , SP 1 SP 5 , SP 1 SP 2 , SP 1 SP 6

No

3.

[ 1 SP 2 , SP ] , SP 1 SP 6

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T,

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.