CHD

CALL HOLD

INDICATES:

A station line has the Call Hold feature.

DATE:

3/12/2009

BILLING:

CRIS

APPLICATIONS:

1AESS, DMS-100, EWSD, FETEX-150, GTD-5 EAX, ISDN BRI, Public Packet Switched Network (PPSN), STROM-DCO, TL1


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@A/TN 732 555-1234/LOC RM 582
     /MTR 7/CCD/SND/CFD/CHD

DMS-100 - Residential
I1   @@A/TN 732 555-1234/CHD R

ISDN Terminal Feature TL1, EWSD
I1   @@W/TSPD 732 555-1234-01
     /TN 732 555-1234/PN 732
     555-1234 SET 1
     /DSNA 10.IBXX.123456..NJ
     /CHD CHDBR, CHDN/USID 1

FID RULES/CONSTRAINTS:

  1. ISDN Circuit Switched Bearer Service
    Section:  S&E      Position:  FL

    For mechanized flow-through, FID may be entered on the  FEATURE  USOC logical line if one of the following combinations of FIDs appear on the same logical line:
         -Primary Number (PN) and Call Appearance (CAPP) (with the CA attribute)
         -PN and Key Designation (KEY)
         -Telephone Number (TN) and Service Profile Identifier (SPID)
         -Telephone Line Identifier (TLI), PN and Terminal Number-Multiline Group (TER)
  2. TL1, EWSD
    The CHD FID may be used without data, to imply a Yes value at either the Directory Number (DN) or terminal level.
  3. The switch default for CHD at the DN level is No.
  4. The switch default for CHD and CHDN at the terminal level is No.
  5. The switch default for CHDBR at the terminal level is Yes.
  6. The switch default for CHDBREL is No.
  7. GTD-5 EAX
    Applicable to non-BBG lines or to denote a feature on a Centrex line shown at the line level rather than at the subgroup level.
  8. GTD-5 EAX, DCO
    Data following the CHD FID is prohibited; the entry of the FID infers a Yes value in the switch.
  9. DCO
    The CHD FID is always shown without data.
  10. SERIES AND RANGE ENTRIES - PROCESSING
    Service Order Analysis and Control System (SOAC) should process series and range data entries using the DUPLICATE algorithm.

REFERENCES:

  1. DMS-100
    NORTEL Practice 297-2101-808, Options CHD, HLD and RCHD; 297-2401-310, option EHLD
  2. TL1 (G3.0)
    TR-NWT-000199, TSP View, Keywords CHD, CHDBR, CHDN; Subscriber Lines and DNCT View, Keyword CHD
  3. TL1 (G4.0)
    TR-NWT-000199, TSP View, Keywords CHD, CHDBR, CHDBREL, CHDN; Subscriber Lines and DNCT View, Keyword CHD; OEDN View, Keyword CHDAM
  4. EWSD
    Siemens Stromberg-Carlson 0770-00010, 0625-00740, Call Hold Features, Keywords CHD, ICHD, CHDBCHR, RCHDBCHR, NOTIFY
  5. FETEX-150
    ES11X-1511-H72, Keyword CHD
  6. GTD-5 EAX
    AG Communication Systems, DNCT View, Keyword CHD

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Optional

Alphabetic

0

10

Element: 1

Residence Call Hold Indicator (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
EEKTS Hold - ISDN  (DMS-100 option EHLD)
PPermanent Hold (DMS-100 option HLD)
RResidential (DMS-100 option RCHD)

Element: 2

Call Hold Options Attribute Name (TL1; EWSD - ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

8

Yes

No

Code Set:

CodeMeaning
CHDBRCHD B-Channel Reservation (TL1)
CHDBRELCall Hold B-Channel Reservation Release (TL1, G4.0; EWSD, APS 12.0)
CHDNCHD Notification (TL1)
RCHDBCHRRelease CHD B-Channel Reservation (EWSD, APS 10.0, 10.5, 11.0 only)

Element Rules:

Code set CHDN is only allowed if the DTSP (Default Terminal Service Profile) FID value equals N.  The DNCT's (Directory Number/Call Type) associated with this terminal (TSP) must be non-BBG for the CHDN code set to appear.
Code set CHDBREL is only allowed when code set CHDBR appears.

Element: 3

Call Hold Options Attribute Values (TL1)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

No.

Element Combination

Series

Separator

1.

1

No

2.

2

Yes

, SP

3.

2 . 3

Yes

, SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, X,R, M

I,O, C,T, D,E, X,R, M

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.