CKL

CIRCUIT LOCATION

INDICATES:

A service (terminating) address at which at least one loop of a special services circuit(s) terminates.  Each service address for a special services circuit must be identified by a unique numeric identifier.

DATE:

10/31/2014

BILLING:

CRIS and CABS

APPLICATIONS:

General Purpose


SECTION - POSITION

EXAMPLES

S&E - LH

CKL 1-295 MAPLE, SUNNYSIDE, NJ

S&E - FL

G1  CKL 1-295 MAPLE, SUNNYSIDE, NJ

              or

R1   @@A/TN 732 555-1234/CKL 1-303
     PELL AV, PISCATAWAY, NJ

ASGM - FL

G1   CKL 5/CLS .FDXX.123456..LL

STAT - LH

CKL  1

FID RULES/CONSTRAINTS:

  1. The numeric identifier of a CKL or Circuit Location Wire Center (CKLT) for the same circuit cannot be assigned the same value.
  2. On C, R or X order types, the FID CKL may be shown recapped without an action code.
  3. Section:  ASGM      Position:  FL
    This FID is entered in the Miscellaneous Subset, Central Office Facilities Subset, and Outside Plant Facilities Subset.
  4. Section:  S&E       Position:  LH, FL
    FID's Local Serving Office (LSO) and Network Channel Interface Code (NCI) are required on the same logical line with CKL for Access Service Tariff application.
  5. Section:  S&E       Position:  LH, FL
    The numeric identifier of a CKL, on a circuit, cannot be reused, within that circuit, until all available numbers have been exausted.  If an Interexchange Carrier (IC) request is made for reuse of numbers, do not reuse them within a 30 day period.
  6. Section:  S&E       Position:  LH
    For Access Service Tariff application C and T Action Codes cannot be used to change the numeric identifier and address or the LSO or CLCI Segment Name (SGN) data floated on the same logical line.
  7. T, F, and X order types prohibited for Access Service application.

REFERENCES:

  1. For use of CKL and its data as a Loop Termination Identifier see Common Language Universal Service Order (USO) Requirements (BR 751-000-151), Section 7, Loop Termination Identification.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - LH

Required

Alphanumeric

11

125

Element: 1

Numeric Identifier

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

4

No

No

Data Parameters:

1-9999 Numeric Identifier

Element: 2

House Number

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

8

No

No

Symbols:

At Sign, Hyphen

Element Rules:

When an at sign (@) is used, it is the only allowable data for this element.  The at sign must precede the Street Name element and indicates that the data following the at sign is to be treated as a street name.
Required when House Number Suffix element appears.

Element: 3

House Number Suffix

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

4

No

No

Symbols:

Virgule

Element Rules:

House Numbers may be suffixed with an alphabetic character(s) or a fraction.  A virgule may appear only as a fraction (must be preceded and followed by a number).
A House Number Suffix is prohibited after an at sign (@).

Element: 4

Street Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

50

No

No

Symbols:

Ampersand, Apostrophe, Asterisk, Hyphen, Space

Element Rules:

Required when House Number element appears.

Element: 5

Community Name

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

3

32

No

No

Symbols:

Ampersand, Apostrophe, Asterisk, Hyphen, Space

Element: 6

State Name

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

2

20

No

No

Symbols:

Space

No.

Element Combination

Series

Separator

1.

1 - 2 - 3 SP 4 , SP 5 , SP 6

No

2.

1 - 2 SP 4 , SP 5 , SP 6

No

3.

1 - , SP 5 , SP 6

No


SECTION - POSITION

S&E - FL

Please refer to S&E - LH for all data requirements.


SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

ASGM - FL

Required

Numeric

1

4

Element: 1

Numeric Identifier

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

4

No

No

Data Parameters:

1-9999

SECTION - POSITION

STAT - LH

Please refer to ASGM - FL for all data requirements.


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I

I

O

O

I,O, C,T

I,O, C,T

-

-

-

Other FIDs Prohibited Logical Line

DPA

DPA

DPA

DPA

DPA

DPA

DPA

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I

I

O

O

I,O, R,D, E,C, T

I,O, R,D, E,C, T

R

-

-

Other FIDs Prohibited Logical Line

DPA

DPA

DPA

DPA

DPA

DPA

DPA

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes

Order Section - Position: ASGM - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

P

O

P

P

Action Codes

I

I

O

O

I,O

-

-

-

-

Other FIDs Prohibited Logical Line

DPA

DPA

DPA

DPA

DPA

-

DPA

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No

Order Section - Position: STAT - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

P

O

P

P

Action Codes

-

-

-

-

-

-

-

-

-

Other FIDs Required Same Section

OCB OR COC

OCB OR COC

OCB OR COC

OCB OR COC

OCB OR COC

-

OCB OR COC

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.