CLT

SPECIAL SERVICE CIRCUIT IDENTIFICATION IN CLCI-S/S TELEPHONE NUMBER FORMAT

INDICATES:

The CLCI-S/S circuit identification in telephone number format.

DATE:

10/31/2014

BILLING:

CRIS and CABS

APPLICATIONS:

General Purpose


SECTION - POSITION

EXAMPLES

S&E - LH

ICLT .SEGS.732.555.1234

S&E - FL

G1   TLI 732 555-1234/HML 1203
I1   @@A/TER 22/SGN AAA/SCS FXSTS
     /CLT 12.FXMX.732.555.1234.T22
G1   TLI 732 555-6543
I1   @@A/SCS FXSTS
     /CLT .FXMX.732.555.6543

ASGM - FL

G2   CLT 12.FXMX.732.555.1234
     .T22/SGN AAA/HML 6203/TER 22
     /TLI 732 555-1234
IOE  12-101-202

FID RULES/CONSTRAINTS:

  1. Section:  S&E     Position:  LH, FL
    If the CLCI Prefix, Service Code and Modifier (PSM) FID is present, CLT may be entered when all FIDs required for its assembly are available. When the CLT FID appears on the service order, PSM is optional.
  2. Section:  ASGM    Position:  FL
    This FID is entered in the Miscellaneous Subset, Central Office Facilities Subset and Outside Plant Facilities Subset.
  3. The CLT FID can appear on a C and T Action Coded logical line but C and T Action Codes cannot be used to change the data following the CLT FID.
  4. T, F, and X order types prohibited for Access Service application.
  5. The CLT FID is not a Primary Line Identifier (PLID).
  6. X action code prohibited on Access Service orders.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - LH

Required

Alphanumeric

18

30

Element: 1

CLCI Prefix

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

2

No

No

Reference:

See BR 795-402-100 for complete list.

Element Rules:

Required when needed for Company local processing.

Element: 2

CLCI Service Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

2

2

No

No

Reference:

See BR 795-402-100 for complete list.

Element: 3

CLCI Modifier

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

2

2

No

No

Reference:

See BR 795-402-100 for complete list.

Element Rules:

Effective 4/1/01, the industry agreed to combine the 5th and 6th position CLCI S/S modifiers into one, 2-character, alphanumeric data element to increase coding power.

Element: 4

Numbering Plan Area Code

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 5

Central Office Code

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 6

Line Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

4

4

Yes

Yes

Data Parameters:

0000-9999

Element Rules:

Series and range usage on Element 6 is mutually exclusive of series and range usage on Element 7.

Element: 7

CLCI Extension Number or Trunk Identifier

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

5

Yes

Yes

Data Parameters:

C1-C480When Primary Line Identifier includes the Call by Call Service B-Channel Number on Primary Rate Integrated Services Digital Network (ISDN) Interface (CXX) FID
D1-D9999When Primary Line Identifier includes the Direct Inward Dialing (DID) FID
F1-F9999Indicates Simulated Facility Number (SFN)
G1-G9999When Primary Line Identifier includes the Outgoing Only Service (OGO) FID
P1-P9999When Primary Line Identifier includes the Private Branch Exchange (PBX) Station Number ( PX ) FID.
S1-S9999When Primary Line Identifier includes the Special Identifying Telephone Number Supplement (SIS)  and Special Identifying Telephone Number (SIT ) FIDs
T0-T4999, T6952-T9999When Primary Line Identifier includes the Terminal Number - Multiline Group (TER) FID
T5000-T6951When Primary Line Identifier includes the  Two-Way Trunk Member Number (TWT ) FID
X1-X9999When Primary Line Identifier includes the Extra Number ( XN ) FID.

Element Rules:

Common Language Practice BR 795-402-100 defines this element as 1-5 alphas, numerics,or alphanumerics. The above Data Parameters have been defined to meet provisioning requirements.
Required for unique identification when Extension Number or Trunk Code is present.

Series and range usage on Element 7 is mutually exclusive of series and range usage on Element 6.

When a simulated facility number is used, the Assignment Not Required (ANR) FID is required.

Element: 8

CLCI Segment Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic or Numeric

1

3

No

No

Data Parameters:

1-999
A-ZZZ

Element Rules:

When a simulated facility number is used, the Assignment Not Required (ANR) FID is required.
Element is prohibited on Access Service orders.

No.

Element Combination

Series

Separator

1.

1 . 2  3 . 4 . 5 . 6

No

2.

1 . 2  3 . 4 . 5 . 6 . 7

No

3.

1 . 2  3 . 4 . 5 . 6 . 7 . 8

No

4.

1 . 2  3 . 4 . 5 . 6 .. 8

No

5.

. 2  3 . 4 . 5 . 6

No

6.

. 2  3 . 4 . 5 . 6 . 7

No

7.

. 2  3 . 4 . 5 . 6 . 7 . 8

No

8.

. 2  3 . 4 . 5 .. 6 .. 8

No


SECTION - POSITION

S&E - FL

Please refer to S&E - LH for all data requirements.


SECTION - POSITION

ASGM - FL

Please refer to S&E - LH for all data requirements.


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T

I,O, C,T

C,T

-

-

Other FIDs Prohibited Logical Line

CLS

CLS

CLS

CLS

CLS

CLS

CLS

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, M,X, D,E, R

I,O, C,T, M,X, D,E, R

C,T, R

-

-

Other FIDs Prohibited Logical Line

CLS

CLS

CLS

CLS

CLS

CLS

CLS

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes

Order Section - Position: ASGM - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

P

O

P

P

Action Codes

I,O

I,O

O

O

I,O

-

-

-

-

Other FIDs Prohibited Logical Line

CLS

CLS

CLS

CLS

CLS

-

CLS

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.