CMCF

CONTROL OF MULTIPLE CALL FORWARDING

INDICATES:

The intergroup and intragroup limits of the number of simultaneous calls forwarded through a Centrex station.

DATE:

1/14/1993

BILLING:

CRIS

APPLICATIONS:

Centrex, DMS-100


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@A/TN 555-8998/CTX ACME:1
     /CAT 23
I1   @@E/TN 555-8998/CFN 4567
     /CMCF CFE.10, CFI.15

REFERENCES:

  1. Northern Telecom BCS 35 Preliminary Document AQ0937SO.AA08.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

12

18

Element: 1

Additional Number of Simultaneous Calls Forwarded - Intergroup Attribute Name

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
CFECalls Forwarded Intergroup

Element: 2

Additional Number of Simultaneous Calls Forwarded - Intergroup Attribute Value

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

4

No

No

Data Parameters:

0 - 1023

Element Rules:

An entry of 0 (zero) indicates that the group level parameter is applied.

Element: 3

Additional Number of Simultaneous Calls Forwarded - Intragroup Attribute Name

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
CFICalls Forwarded Intragroup

Element: 4

Additional Number of Simultaneous Calls Forwarded - Intragroup Attribute Value

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

4

No

No

Data Parameters:

0 - 1023

Element Rules:

An entry of 0 (zero) indicates that the group level parameter is applied.

No.

Element Combination

Series

Separator

1.

1 . 2 , SP 3 . 4

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.