CPDN

CALLING PARTY DEFAULT DIRECTORY NUMBER

INDICATES:

5ESS
The main DN to be used as Calling Party Number (CPN) in the absence of a valid CPN.

TL1, EWSD
The Calling Party Default DN for each call type on an Integrated Services Digital Network (ISDN) interface (pipe), or the Terminal Service Profile (TSP).

DMS-100
For ISDN PRI, the calling number associated with the logical terminal should be used as the default Calling Party Number.

DATE:

10/13/2005

BILLING:

CRIS and CABS

APPLICATIONS:

5ESS, DMS-100, EWSD, FETEX-150, ISDN BRI, ISDN PRI, TL1


SECTION - POSITION

EXAMPLES

S&E - FL

ISDN PIPE (TL1, EWSD)
ISDN Terminal Service Profile (TSP) (TL1, EWSD APS 13.0)
I1    @@W/TSPD 732 555-1234-01
      /TN 732 555-1234/PN 732 555-1234 SET 1
      /DSNA 10.IBZX.123456..NJ/CPDN
      7325551501, VI; 7325553210, CMD

ISDN PRI (TL1, G4.0; EWSD, APS 12.0)
IPRIN|PRI001/CPDN 7325551234, VI;
      7325552345, CMD

5ESS PRI
ITGP  A-344/CPDN 7325551234

ISDN PRI (DMS-100 Table)
ITGP  A-344/CPDN

FID RULES/CONSTRAINTS:

  1. T, F, and X order types prohibited for Access Service application.
  2. X action code prohibited on Access Service orders.

SERVICE ORDER ACTIVITY NOTES:

  1. TL1, EWSD
    When CPDN is assigned to a pipe, the AMA recordings for all terminals on the pipe will appear on the default DN.
  2. TL1, EWSD
    Only one DN is allowed per call type.
  3. TL1
    When CPDN is assigned at the TSP level, it will override the required entry at the OE level.
  4. DMS-100 Table
    This FID is not recommended for provisioning because it involves table edits and does not use SERVORD.  It was developed for tracking and administrative purposes.

REFERENCES:

  1. TL1
    TR-NWT-000199, OE, TSP, and PRI Views, Keyword CPDDN.
  2. EWSD
    Siemens Stromberg-Carlson 1090-00010 Command CR SUB, CR ACCESS, CR TSP, 0770-00010 Keyword CPDDN.
  3. 5ESS
    Lucent Technologies 235-118-257, View 5.1, Keyword MAINDN.
  4. DMS-100 Table
    NORTEL documentation 297-2401-200 Functional Group Ordering Code NI000015, Table LTDATA.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Optional

Alphanumeric

0

15

Element: 1

Default Directory Number (TL1, EWSD, FETEX-150)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

7

10

No

No

Element Rules:

The EWSD switch requires a 10 digit entry.

Element: 2

Default Directory Number Call Type (TL1, EWSD, FETEX-150)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

3

No

No

Code Set:

CodeMeaning
VIVoice
CMDCircuit Mode Data
PMDPacket Mode Data
ALLAll Call Types

Element Rules:

TL1, EWSD
If code set ALL is used, code sets VI, CMD, and PMD are not allowed.

Element: 3

Main Directory Number (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

10

10

No

No

No.

Element Combination

Series

Separator

1.

1 , SP 2

3

; SP

2.

3

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.