CPG

CALL PICKUP GROUP

INDICATES:

The call pickup group number for a PBX station, or a Stored Program Controlled Switch (SPCS) station line, when that line is contained in a call pickup group and may also indicate the line number of each line in the group.

DATE:

7/7/2005

BILLING:

CRIS and CABS

APPLICATIONS:

2ESS, 5ESS, AXE, DMS-10, DMS-100, EWSD, FETEX-150, GTD-5 EAX, TL1


SECTION - POSITION

EXAMPLES

S&E - LH

Call Pickup Group except DMS-100 with series and range entry
ICPG 5-1234, 1237, 1285-1287

Call Pickup Group entry with Series and Range for DMS-100 BCS 26 Option
ICPG 13206-0611, 0617-0619

Call Pickup Group Entry with Series and Range for DMS-100
ICPG 6830611-0611, 0617-0619

S&E - FL

Call Pickup Group entry (Centrex)
I1   @@A/TN 1234/CPG 5/CAT 4
     /LCC ABC

Call Pickup Group entry (PBX)
I1   @@A/PX 2549/CPG 7

Call Pickup Group entry (5ESS) Centrex station line in multiple groups
I1   @@A/TN 1234/CAT 4/LCC ABC
     /CPG 25, 65, 82, 161

Call Pickup Group entry for DMS-100
I1   @@A/TN 3115/CPG 3964596

Call Pickup Group entry for DMS-100 BCS-26 option
I1   @@A/TN 3115/CPG 396

Call Pickup Group entry for DMS-10
I1   @@A/TN 5344/CPG 15

EWSD Centrex
I1   @@A/TN 732 555-1234/ORM 1/CTX 10
     /CPG 15

EWSD Multiline Hunt
IHML 10-TER HI-3/HTY RG/CPG 12

EWSD Unbundled MVP
I1   @@A/TN 732 555-1234/MVP MAST
     555-1234, PROP8, INT 20
     /TWC/CHD/CPG ROO

AXE, GTD-5 EAX
I1   @@A/TN 732 555-1234/CPG 98

TL1-ISDN (Release 3.0 and Prior)
I1   @@A/TN 732 555-1234/CPG 91, 20, 13,
     3 CPUB.D

TL1-ISDN (Release 4.0 and Later)
I1   @@A/TN 732 555-1234/CPG 91, 20,
     13 CPGACC.1234, 5678, 4321
      CPUB.D

FID RULES/CONSTRAINTS:

  1. When CPG appears left-handed, it must also appear floated after the appropriate line USOC(s).
  2. EWSD
    CPG may be assigned to a Centrex multiline hunt group instead of individual HML members. When CPG is assigned to the hunt group, CPG is floated on the left hand HML logical line.
  3. T, F, and X order types prohibited for Access Service application.
  4. X action code prohibited on Access Service orders.

SERVICE ORDER ACTIVITY NOTES:

  1. When the FID CPG appears left-handed, it identifies all station lines in a call pickup group.
  2. In the 5ESS switch, when the call pickup group number entry is in series, the first number in the series indicates both originating and terminating call pickup feature group number (queue) value. The second and subsequent call pickup group number entries in series indicate additional originating feature group number (queue) values. To implement more complex 5ESS CPG originate/terminate feature combinations, utilize the CPUO and CPUT FIDs.
  3. CPG is valid for TL1 Generic Interface Release G3.0 and later.  For Release G2.0 see CPUO and CPUT FIDs.

REFERENCES:

  1. EWSD
    Siemens 0625-00750, Call Pick Up; Siemens 0770-00010, CPUGRP, ROO
  2. TL1 (Release 3.0 and Prior)
    TR-NWT-000199, Subscriber Lines and DNCT View, Keywords CPG, CPUB
  3. TL1 (Release 4.0 and Later)
    TR-NWT-000199, Subscriber Lines and DNCT View, Keywords CPG, CPGACC
  4. FETEX-150
    ES11X-151-H72, Parameters CPG and CPUG
  5. GTD-5 EAX
    AG Communication Systems, DNCT View, Keyword CPG

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - LH

Required

Numeric

3

12

Element: 1

Call Pickup Group Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

7

4

No

Data Parameters:

0-99991AESS, 2ESS
2-655355ESS
1-32767DMS-100 Optional with BCS 26
1-50DMS-10
2000000-9999999DMS-100
1-4095EWSD, FETEX-150
1-65535AXE
1-9999TL1
0-4095GTD-5 EAX

Element: 2

Centrex Line Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

4

4

Yes

Yes

Data Parameters:

0000-9999

Element Rules:

A series or range entry is required.

Element: 3

PBX Station Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

Yes

Yes

Data Parameters:

1-9999

Element Rules:

A series or range entry is required.

No.

Element Combination

Series

Separator

1.

1 - 2

No

2.

1 - 3

No


SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

1

28

Element: 1

Call Pickup Group Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

7

4

No

Data Parameters:

0-99991AESS, 2ESS
2-655355ESS
1-32767DMS-100 Optional with BCS 26
2000000-9999999DMS-100
1-50DMS-10
1-4095EWSD, FETEX-150
1-65535AXE
1-9999TL1
0-4095GTD-5 EAX

Element Rules:

5ESS
A series of group numbers is allowed. The display of group numbers in a series also identifies the preferred sequence of those groups.
TL1, FETEX-150
A series of group numbers is allowed for ISDN only.

Element: 2

Call Pickup Group Access Codes Attribute Name (TL1)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

6

6

4

No

Code Set:

CodeMeaning
CPGACCCall Pickup Group Access Codes

Element: 3

Call Pickup Group Access Codes Attribute Value (TL1)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

5

4

No

Code Set:

CodeMeaning
1-99999Call Pickup Group Access Codes

Element: 4

Call Pickup Billing Records Attribute Name (TL1)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
CPUBCall Pickup Billing Records

Element: 5

Call Pickup Billing Records Attribute Value (TL1)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

2

No

No

Code Set:

CodeMeaning
DDetailed
NNone
UGUse The Customer Group Value
USUse The Per Switch Value

Element Rules:

The switch default for customer group members is UG, Use Customer Group value.
The switch default for DN/CTs not in a customer group is US, Use Per Switch value.

Element: 6

Internally Assigned Call Pickup Group Number (EWSD)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
ROOCPG Number is internally assigned by the switch

Element Rules:

The MVP FID must appear on the same logical line when this code set appears.

No.

Element Combination

Series

Separator

1.

1

4

, SP

2.

1 SP 2 . 3

4

, SP

3.

1 SP 2 . 3 SP 4 . 5

No

4.

1 SP 4 . 5

No

5.

6

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

P

P

P

Action Codes

I

I

O

O

I,O

I,O

-

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.