CPUO

CALL PICKUP ORIGINATING

INDICATES:

5ESS
The Call Pickup Originating feature name(s) and optional feature attributes to be assigned to a line.

TL1
The Call Pickup Originating  Dial Access Code and Call Pickup Group.

DATE:

3/2/2006

BILLING:

CRIS

APPLICATIONS:

5ESS, TL1


SECTION - POSITION

EXAMPLES

S&E - LH

5ESS
ICPUO|26-*CPUO SELQ1.3, SELQ2.9

S&E - FL

5ESS
I1    @@A/TN 732 555-1234/CPUO 26

         or

I1    @@A/TN 732 555-1234/CPUO *CPUO
      SELQ1.3, SELQ2.9

TL1  -  G2.0
I1    @@A/TN 732 555-1234/CPUO 1-4391,
      2-4392, 3-4395

FID RULES/CONSTRAINTS:

  1. SERIES AND RANGE ENTRIES - PROCESSING
    Service Order Analysis and Control System (SOAC) should process series and range data entries using the DUPLICATE algorithm.

REFERENCES:

  1. 5ESS
    Lucent Technologies 235-118-257, Views 12.13, 23.8, Keywords SELQ1, SELQ2, NOTIFY1, NOTIFY2, PORTLSCC .
  2. TL1  -  G2.0
    TA-TSY-000199, Keyword CPUO.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - LH

Required

Alphanumeric

3

33

Element: 1

Call Pickup Originating Feature List Number (5ESS)

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

3

No

No

Data Parameters:

1-999

Element: 2

Call Pickup Originating Feature Name (5ESS)

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

1

8

Yes

No

Code Set:

CodeMeaning
*CPUDODirected Call Pickup (Originating)
*CPUEOCall Pickup Emergency Override (Originating)
*CPUO2Call Pickup Originating (Two Groups)
*CPUOCall Pickup Originating or Trunk Answer Any Station Originating
*CPUVOCall Pickup Busy Verify (Originating)

Symbols:

Asterisk

Element Rules:

Lucent has defined most of the popular assignable service features, which are referred to as “pre-constructed” features and are identified on a FID by a mandatory leading asterisk “*”.  Additionally, system administrators are able to locally customize additional assignable features, which are referred to as “constructible” features.  Constructible features are locally developed, do not contain a leading asterisk and have 1-8 character feature names.  The Feature field is used to define both “pre-constructed” and “constructible” types of features.

The series separator is semicolon space.

Element: 3

Call Pickup Originating Attribute Name (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

5

8

No

No

Code Set:

CodeMeaning
SELQ1Predesignated Queue 1
SELQ2Predesignated Queue 2
NOTIFY1Notification Option 1
NOTIFY2Notification Option 2
PORTLSCCEquipment Number Port Identification

Element: 4

Call Pickup Originating Attribute Value (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

11

No

No

Code Set:

CodeMeaning
NOTIFY1 and NOTIFY2 Attribute Values
YYes
NNo

Data Parameters:

SELQ1 and SELQ2 Attribute Values
2-65535
PORTLSCC Attribute Value
D1-D9999999999
N1-N9999999999
P1-P9999999999
R1-R9999999999
T1-T9999999999

No.

Element Combination

Series

Separator

1.

1 - 2

No

2.

1 - [ 2 SP [ 3 . 4 , SP ] ; SP ]

No


SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

1

29

Element: 1

Call Pickup Originating Feature List Number (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

1-999

Element Rules:

When element 1 is used, there must be a corresponding LH entry.

Element: 2

Call Pickup Originating Feature Name (5ESS)

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

1

8

Yes

No

Code Set:

CodeMeaning
*CPUDODirected Call Pickup (Originating)
*CPUEOCall Pickup Emergency Override (Originating)
*CPUO2Call Pickup Originating (Two Groups)
*CPUOCall Pickup Originating or Trunk Answer Any Station Originating
*CPUVOCall Pickup Busy Verify (Originating)

Symbols:

Asterisk

Element Rules:

Lucent has defined most of the popular assignable service features, which are referred to as “pre-constructed” features and are identified on a FID by a mandatory leading asterisk “*”.  Additionally, system administrators are able to locally customize additional assignable features, which are referred to as “constructible” features.  Constructible features are locally developed, do not contain a leading asterisk and have 1-8 character feature names.  The Feature field is used to define both “pre-constructed” and “constructible” types of features.

The series separator is semicolon space.

Element: 3

Call Pickup Originating Attribute Name (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

5

8

No

No

Code Set:

CodeMeaning
SELQ1Predesignated Queue 1
SELQ2Predesignated Queue 2
NOTIFY1Notification Option 1
NOTIFY2Notification Option 2
PORTLSCCEquipment Number Port Identification

Element: 4

Call Pickup Originating Attribute Value (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

11

No

No

Code Set:

CodeMeaning
NOTIFY1 and NOTIFY2 Attribute Values
YYes
NNo

Data Parameters:

SELQ1 and SELQ2 Attribute Values
2-65535
PORTLSCC Attribute Value
D1-D9999999999
N1-N9999999999
P1-P9999999999
R1-R9999999999
T1-T9999999999

Element: 5

Call Pickup Group Originating Dial Access Code (TL1 - G2.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

1-4

Element: 6

Originating Call Pickup Group Number (TL1 - G2.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

4

4

No

No

No.

Element Combination

Series

Separator

1.

1

No

2.

2

Yes

; SP

3.

2 SP [ 3 . 4 , SP ]

Yes

; SP

4.

5 - 6

4

, SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T

I,O, C,T

I,O

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, E,D, M,X, R

I,O, C,T, E,D, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.