CPVD

CALLING PARTY VALID DIRECTORY NUMBERS

INDICATES:

The set of valid Directory Numbers (DNs) for an Integrated Services Digital Network (ISDN) Primary Rate Interface (PRI) against which the calling number is screened.

DATE:

10/27/2005

BILLING:

CRIS

APPLICATIONS:

5ESS, DMS-100, EWSD, ISDN PRI, TL1


SECTION - POSITION

EXAMPLES

S&E - FL

TL1
IPRIN|PRI001/CPVD 7325556677-
      7325556700, 7325554432-
      7325554500

5ESS, DMS-100 Table
ITGP  A-344/CPVD 7325556677-
      7325556700, 7325554432-
      7325554500

EWSD
IPRIN|PRI001/CPVD 7325556700-
      7325556750, 7325554321,
      7325556677, 7325554656

SERVICE ORDER ACTIVITY NOTES:

  1. TL1
    An individual DN value is not allowed.  The value must always appear in a range. Up to 20 DN ranges are allowed and can include up to 1000 DNs.
  2. 5ESS
    An individual DN value is not allowed.  The value must always appear in a range.  Up to 20 DN ranges are allowed.
  3. DMS-100
    This FID is not recommended for provisioning beacuse it involves table edits and does not use SERVORD.  It was developed for tracking and administrative purposes.

REFERENCES:

  1. TL1, G4.0
    TR-NWT-000199, PRI View, Keyword CPVDN.
  2. 5ESS
    Lucent Technologies 235-118-257, View 7.5, Keyword SCREENINGRANGES
  3. EWSD
    Siemens, Stromberg-Carlson, 0770-00010, Keyword CPVDN1; 1090-00010, Command CR ACCESS.
  4. DMS-100
    NORTEL Practice 297-2401-200, Functional Group Ordering Code NI00025, Table LTDATA.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Numeric

10

21

Element: 1

Beginning Directory Number in Range (TL1, G4.0; 5ESS, DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

10

10

No

No

Element: 2

Ending Directory Number in Range (TL1, G4.0; 5ESS, DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

10

10

No

No

Element: 3

Directory Number Range (EWSD)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

10

10

Yes

Yes

Element Rules:

A maximum of 200 individual DNs and 64 DN ranges may be entered.

No.

Element Combination

Series

Separator

1.

1 - 2

20

, SP

2.

3

Yes

, SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.