CZ

CARRIER ZONE

INDICATES:

The carrier resistance zone of a line working in a Pair Gain System.

DATE:

1/1/1988

BILLING:

CRIS and CABS

APPLICATIONS:

General Purpose


SECTION - POSITION

EXAMPLES

ASGM - FL

RT   4101/CZ 16/OAB MNS
IOE  16-123/DF 11-105A
IF1  /CA PG 101/PR 16/BP 16
     /TEA 205 MAIN; PXJ/PGS SLC40,
     12/LT 16
IF2  /CA 1201/PR 11/BP 1
     /TEA 208 NORTH

FID RULES/CONSTRAINTS:

  1. This FID is entered in the Miscellaneous Subset.

SERVICE ORDER ACTIVITY NOTES:

  1. The carrier resistance zone is calculated from the Remote Terminal and is not equal to the RZ (Resistance Zone) for physical cable pairs.

REFERENCES:

  1. See BR 680-201-018 for details.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

ASGM - FL

Required

Numeric

1

2

Element: 1

Carrier Zone

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

2

No

No

Code Set:

CodeMeaning
40-400  ohms
9401-900  ohms
15901-1500 ohms
161501-1600 ohms
281601-2800 ohms
362801-3600 ohms

ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: ASGM - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

P

O

P

P

Action Codes

I

I

O

O

I,O

-

-

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.