DLCI

DATA LINK CONNECTION IDENTIFICATION

INDICATES:

The near and remote logical addresses of a Frame Relay permanent virtual circuit.

DATE:

6/21/2007

BILLING:

CRIS and CABS

APPLICATIONS:

Access Service, Access Service Request (ASR), FETEX-150, Frame Relay, Local Competition, Local Service Request (LSR)


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@H/CLS 10.FBXX.123456..NJ
     /DTN 732 555-1234/DLCI 16, 23

               or

I1   @@H/CLS 10.FBXX.123456..NJ
     /DTN 732 555-1234/DLCI 16, RDLCI 16

FID RULES/CONSTRAINTS:

  1. T, F, and X order types prohibited for Access Service application.
  2. X action code prohibited on Access Service orders.

SERVICE ORDER ACTIVITY NOTES:

  1. This FID, when used in series or range, is redundant with the Packet Switch Options (PSO) FID elements that provision RDLCI data.

REFERENCES:

  1. Fujitsu, Translation Guide, ES19X-1516-M72, keywords DLCI, RDLCI.
  2. ATIS/OBF-ASR-011 and 023, DLCI field
  3. ATIS/OBF-LSR-079 and 099, DLCI field

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

2

16

Element: 1

Data Link Connection Identification Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

2

4

Yes

Yes

Data Parameters:

16-1007

Element Rules:

If element appears in series or range, the second data parameter represents the remote DLCI.

Element: 2

Remote Data Link Connection Identification Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

5

5

No

No

Code Set:

CodeMeaning
RDLCIRemote DLCI

Element Rules:

If element 1 appears in a series or range, element 2 is prohibited.

Element: 3

Remote Data Link Connection Identification Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

2

4

No

No

Data Parameters:

16-1007

Element Rules:

If element 1 appears in a series or range, element 3 is prohibited.

No.

Element Combination

Series

Separator

1.

1

Yes

, SP

2.

1 , SP 2 SP 3

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.