DP

DISTRIBUTOR POINT

INDICATES:

The number of the distributor point assigned to lines requiring a signal upon origination and at termination of a connection.

DATE:

3/31/2005

BILLING:

CRIS

APPLICATIONS:

1AESS, 2ESS, 3ESS, 5ESS, DMS-100, EWSD


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@A/TN 732 555-1234/DP 002113031

DMS-100 UCD
I1   @@A/TN 732 555-1234/DP 4 2

ASGM - FL

1AESS
     /DP 1,U10250

2ESS
     /DP 0055 01

3ESS
     /DP 1 000 2 1

5ESS
     /DP 002113031

DMS-100
     /DP MTM 131551

MAS Generic Interface
     /DP AB123C

FID RULES/CONSTRAINTS:

  1. Section:  ASGM      Position:  FL
    This FID is entered in the Central Office Facilities Subset.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

1

12

Element: 1

Quantity of DP (1AESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

1-9

Element: 2

Frame Type (1AESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
UUniversal Trunk Frame
SSupplementary Trunk Frame
MMiscellaneous Trunk Frame
JJunctor Frame

Element: 3

Frame Number (1AESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

2

2

No

No

Data Parameters:

01-99

Element: 4

Point Number (1AESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Data Parameters:

000-999

Element: 5

Central Pulse Distributor Number (2ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

0-7

Element: 6

Central Pulse Distributor Test (2ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

0-7

Element: 7

Central Pulse Distributor Cards (2ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

0-7

Element: 8

Central Pulse Distributor Point (2ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

0-7

Element: 9

P D Buffer (2ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

0-3

Element: 10

Buffer Point (2ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

0-2

Element: 11

Peripheral Pulse Distributor (3ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

0-1

Element: 12

Peripheral Decoder (3ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Data Parameters:

000-255

Element: 13

Triplet (3ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

0-3

Element: 14

Point (3ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

0-2

Element: 15

Switching Module (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Data Parameters:

001-192

Element: 16

Metalic Service Unit (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

0-1

Element: 17

Service Group (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

0-1

Element: 18

Board (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

2

2

No

No

Data Parameters:

00-31

Element: 19

Point (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

2

2

No

No

Data Parameters:

00-31

Element: 20

Distributor Point Number (MAS Generic Interface)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

10

No

No

Element: 21

Trunk Module (TM) Type (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
MTMMaintenance Trunk Module
RSMRemote Switch Module

Element: 22

TM Number (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

0-2047

Element: 23

TM Circuit Number (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

0-29

Element: 24

Point (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

0-6

Element: 25

Normal State (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Code Set:

CodeMeaning
0Open
1Closed

Element: 26

Signal Distributor (SD) Group Number (DMS-100 UCD)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

0-511

Element: 27

SD Point Number (DMS-100 UCD)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

0-6

No.

Element Combination

Series

Separator

1.

1 , 2  3  4

No

2.

5  6  7  8 SP 9  10

No

3.

11 SP 12 SP 13 SP 14

No

4.

15  16  17  18  19

No

5.

20

No

6.

21 SP 22  23  24  25

No

7.

26 SP 27

No


SECTION - POSITION

ASGM - FL

Please refer to S&E - FL for all data requirements.


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, X,R, M

I,O, C,T, D,E, X,R, M

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No

Order Section - Position: ASGM - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

P

O

P

P

Action Codes

I

I

O

O

I,O

-

I,O

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.