DPEZ

DROP PORT EQUIPMENT ASSIGNMENT - LOCATION Z

INDICATES:

The physical drop ports and/or equipment at the exit point of the provider's network when the customer has assignment control.

DATE:

10/31/2014

BILLING:

CRIS and CABS

APPLICATIONS:

Access Service, Access Service Request (ASR), Synchronous Optical Network (SONET)


SECTION - POSITION

EXAMPLES

S&E - FL

IG1  CLS .HCGS.123456..CO/NCI 04DS9.15
     /DPEZ DNVRCOMA 00 030303.020
     DNVRCOMA31 T1G111-T1G112


IG2  CKL 1-400 BROAD ST, CHICAGO, IL
     /LSO 847 555/NCI O4ST6.A
     /DPEZ CHCGILFRH01 030303.020
     SNMSBRA2RA 1011

FID RULES/CONSTRAINTS:

  1. T, F, and X order types prohibited for Access Service Application.
  2. Element combinations one and two are currently not supported by Telcordia and/or Ericsson Operations Support Systems (OSSs).

REFERENCES:

  1. ATIS/OBF-ASR-024, DPEAZ field

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

29

51

Element: 1

COMMON LANGUAGE Geographical Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

4

4

No

No

Data Parameters:

A-Z

Symbols:

Space

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Geographical Codes created after 11/8/95 must be 4 alpha characters.

Geographical Codes created prior to 11/8/95 were two to four alpha characters.  Two or 3 character codes were left justified and the unused (rightmost) positions were balnk filled.  It is for the latter reason that use of the "space' text symbol is permitted and, as a result, the element mode must be shown as "AN".

The actual numeric character values of 0 through 9 are not, nor have they ever been, allowed within the Geographical Code.
Required as specified in BR 795-100-100.

Element: 2

COMMON LANGUAGE Geopolitical Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 3

CLLI Network Site Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic or Numeric

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 4

CLLI Network Entity Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

3

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 5

Node

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

2

2

No

No

Element: 6

Floor

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

2

2

No

No

Reference:

Refer to BR 751-100-785 for details.

Element: 7

Lineup

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

1

5

No

No

Reference:

Refer to BR 751-100-785 for details.

Element Rules:

SOAC supports a maximum of 4 alphanumeric characters.

Element: 8

Bay Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

2

2

No

No

Data Parameters:

00 - 99

Reference:

Refer to BR 751-100-785 for details.

Element: 9

Bay Designation

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

1

1

No

No

Reference:

Refer to BR 751-100-785 for details.

Element: 10

CLEI Family Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

2

2

No

No

Reference:

Refer to BR 795-200-000 for details.

Element: 11

CLEI Sub-Family Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

2

2

No

No

Reference:

Refer to BR 795-200-000 for details.

Element: 12

CLEI Major Features Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

1

1

No

No

Reference:

Refer to BR 795-200-000 for details.

Element: 13

CLEI Minor Features Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

2

2

No

No

Reference:

Refer to BR 795-200-000 for details.

Element: 14

CLEI Reference Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

1

1

No

No

Reference:

Refer to BR 795-200-000 for details.

Element: 15

CLEI Complemental Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

2

2

No

No

Reference:

Refer to BR 795-200-000 for details.

Element: 16

Starting Number Assignment

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

1

6

No

No

Element: 17

Ending Number Assignment

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

6

No

No

No.

Element Combination

Series

Separator

1.

1  2  3  4 SP 5 SP 6  7 . 8  9 SP 10  11  12  13  14  15 SP 16

No

2.

1  2  3  4 SP 5 SP 6  7 . 8  9 SP 10  11  12  13  14  15 SP 16 - 17

No

3.

1  2  3  4 SP 6  7 . 8  9 SP 10  11  12  13  14  15 SP 16

No

4.

1  2  3  4 SP 6  7 . 8  9 SP 10  11  12  13  14  15 SP 16 - 17

No

5.

1  2  3 SP 5 SP 6  7 . 8  9 SP 10  11  12  13  14  15 SP 16

No

6.

1  2  3 SP 5 SP 6  7 . 8  9 SP 10  11  12  13  14  15 SP 16 - 17

No

7.

1  2  3 SP 6  7 . 8  9 SP 10  11  12  13  14  15 SP 16

No

8.

1  2  3 SP 6  7 . 8  9 SP 10  11  12  13  14  15 SP 16 - 17

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,R

I,O, C,T, D,E, M,R

I,O,C,T,R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.