DSRC |
DEDICATED SONET RING CIRCUIT |
INDICATES: |
The dedicated SONET ring circuit number. |
DATE: |
12/9/2004 |
BILLING: |
CABS |
APPLICATIONS: |
Access Service, Billing, Synchronous Optical Network (SONET) |
SECTION - POSITION |
EXAMPLES |
S&E - FL |
|
ICKL 1-1234 PARK AV, MANHATTAN, NY |
SERVICE ORDER ACTIVITY NOTES: |
|
SECTION - POSITION |
APPEARANCE |
MODE |
MIN |
MAX |
S&E - FL |
Required |
Alphanumeric |
21 |
36 |
Element: 1 |
CLFI Transmission Facility Designation Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Required |
Alphanumeric |
1 |
5 |
No |
No |
Reference: |
See BR 795-450-100 for complete list. |
Element: 2 |
CLFI Transmission Facility Type Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Required |
Alphanumeric |
1 |
6 |
No |
No |
Reference: |
See BR 795-450-100 for complete list. |
Element: 3 |
COMMON LANGUAGE Geographical Code (A Location) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Required |
Alphanumeric |
4 |
4 |
No |
No |
Data Parameters: |
||
|
Symbols: |
Space |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
||
|
Element: 4 |
COMMON LANGUAGE Geopolitical Code (A Location) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Required |
Alphabetic |
2 |
2 |
No |
No |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
Required as specified in BR 795-100-100. |
Element: 5 |
CLLI Network Site Code (A Location) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Required |
Alphabetic or Numeric |
2 |
2 |
No |
No |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
Required as specified in BR 795-100-100. |
Element: 6 |
CLLI Network Entity Code (A Location) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
3 |
3 |
No |
No |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
Required as specified in BR 795-100-100. |
Element: 7 |
COMMON LANGUAGE Geographical Code (Z Location) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
4 |
4 |
No |
No |
Data Parameters: |
||
|
Symbols: |
Space |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
||
|
Element: 8 |
COMMON LANGUAGE Geopolitical Code (Z Location) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Required |
Alphabetic |
2 |
2 |
No |
No |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
Required as specified in BR 795-100-100. |
Element: 9 |
CLLI Network Site Code (Z location) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Required |
Alphabetic or Numeric |
2 |
2 |
No |
No |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
Required as specified in BR 795-100-100. |
Element: 10 |
CLLI Network Entity Code (Z Location) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
3 |
3 |
No |
No |
Reference: |
See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli. |
Element Rules: |
Required as specified in BR 795-100-100. |
No. |
Element Combination |
Series |
Separator |
1. |
1 SP 2 SP 3 4 5 6 SP 7 8 9 |
No |
|
2. |
1 SP 2 SP 3 4 5 6 SP 7 8 9 10 |
No |
|
3. |
1 SP 2 SP 3 4 5 SP 7 8 9 |
No |
|
4. |
1 SP 2 SP 3 4 5 SP 7 8 9 10 |
No |
ORDER TYPE/ACTION CODE/FID RELATIONSHIPS |
Order Section - Position: S&E - FL
|
Order Type |
N |
T |
F |
D |
C |
R |
X |
P |
A |
Presence |
O |
P |
P |
O |
O |
O |
P |
P |
P |
Action Codes |
I, E |
- |
- |
O, D |
I, O, C, T, D, E, M, R |
I, O, C, T, D, E, M, R |
- |
- |
- |
CRIS |
CABS |
|
Data Retention |
No |
Yes |
Printed on CSR |
No |
Yes |
Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure. |
iconectiv Confidential - Restricted Access This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv. |
Licensed Material - Property of iconectiv Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv. |