DUSO |
DATA UNIT SET UP OPTIONS |
INDICATES: |
Data Unit Options for speed, format and data length. |
DATE: |
8/9/1990 |
BILLING: |
CRIS |
APPLICATIONS: |
DMS-100, Data Service |
SECTION - POSITION |
EXAMPLES |
S&E - FL |
|
I1 @@H/DUSO OM.LEASED, SPD.300, |
REFERENCES: |
|
SECTION - POSITION |
APPEARANCE |
MODE |
MIN |
MAX |
S&E - FL |
Required |
Alphanumeric |
6 |
116 |
Element: 1 |
Set Up Attributes |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
2 |
4 |
No |
No |
Code Set: |
||||||||||||||||||
|
Element: 2 |
Set Up Values |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
3 |
6 |
No |
No |
Data Parameters: |
||
|
Element: 3 |
Data Unit Options (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
6 |
8 |
No |
No |
Code Set: |
||||||||||||||||||||
|
Element: 4 |
Class of Data Unit Option Values (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
2 |
6 |
No |
No |
Code Set: |
||||||||||||||||||||||||||||||||
|
Element Rules: |
Element required when code set CLASSDU on Element 3 is used. |
Element: 5 |
Download Option Values (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
1 |
No |
No |
Code Set: |
||||||
|
Element Rules: |
Element required when code set DOWNLOAD on Element 3 is used. |
Element: 6 |
Configuration Option Vlaues (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
3 |
3 |
No |
No |
Code Set: |
||||||
|
Element Rules: |
Element required when code set CONFIG on Element 3 is used. |
Element: 7 |
Transmission Option Values (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
1 |
No |
No |
Code Set: |
||||||
|
Element Rules: |
Element required when code set SYNCHRO on Element 3 is used. |
Element: 8 |
Character Length Option Values (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Data Parameters: |
||
|
Element Rules: |
Element required when code set CHARLEN on Element 3 is used. Element used with asynchronous only. |
Element: 9 |
Clocking Source Option Values (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
1 |
No |
No |
Code Set: |
||||||
|
Element Rules: |
Element required when code set CLOCKSRC on Element 3 is used. Element applies to synchronous only. |
Element: 10 |
Duplex Option Values (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
1 |
No |
No |
Code Set: |
||||||
|
Element Rules: |
Element required when code set DUPLEX on Element 3 is used. |
Element: 11 |
Keyboard Dialing Option Value (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
1 |
No |
No |
Code Set: |
||||||
|
Element Rules: |
Element required when code set KEYBDIAL on Element 3 is used. |
Element: 12 |
Type of Keyboard Dialing Values (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
3 |
5 |
No |
No |
Code Set: |
||||||||
|
Element Rules: |
Element required when code set KBDTYP on Element 3 is used. |
Element: 13 |
Keyboard Prompts Indicator (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
7 |
7 |
No |
No |
Code Set: |
||||
|
Element Rules: |
Element required when code set SYMB on Element 12 is used. |
Element: 14 |
Keyboard Prompts Value (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
1 |
No |
No |
Code Set: |
||||||
|
Element: 15 |
Idle Timeout Indicator (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
6 |
6 |
No |
No |
Code Set: |
||||
|
Element Rules: |
Element required when code set AILC is used on Element 4. |
Element: 16 |
Idle Timeout Value (DMS-100) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
1 |
No |
No |
Code Set: |
||||||||||
|
No. |
Element Combination |
Series |
Separator |
1. |
1 . 2 |
Yes |
, SP |
2. |
3 . 4 |
No |
|
3. |
3 . 4 , SP 3 . 5 , SP 3 . 6 , SP 3 . 7 , SP 3 . 8 , SP 3 . 10 , SP 3 . 11 , SP 3 . 12 , SP 13 . 14 |
No |
|
4. |
3 . 4 , SP 3 . 5 , SP 3 . 6 , SP 3 . 7 , SP 3 . 8 , SP 3 . 10 , SP 3 . 11 , SP 3 . 12 , SP 15 . 16 |
No |
|
5. |
3 . 4 , SP 3 . 5 , SP 3 . 6 , SP 3 . 7 , SP 3 . 9 , SP 3 . 10 |
No |
|
6. |
3 . 4 , SP 3 . 5 , SP 3 . 6 , SP 3 . 7 , SP 3 . 9 , SP 3 . 10 , SP 3 . 11 , SP 3 . 12 |
No |
ORDER TYPE/ACTION CODE/FID RELATIONSHIPS |
Order Section - Position: S&E - FL
|
Order Type |
N |
T |
F |
D |
C |
R |
X |
P |
A |
Presence |
O |
O |
O |
O |
O |
O |
O |
P |
P |
Action Codes |
I,E |
I,E |
D,O |
D,O |
I,O, C,T, D,E, X,R, M |
I,O, C,T, D,E, R |
I,O, C,T, D,E, R |
- |
- |
CRIS |
CABS |
|
Data Retention |
Yes |
No |
Printed on CSR |
Yes |
No |
Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure. |
iconectiv Confidential - Restricted Access This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv. |
Licensed Material - Property of iconectiv Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv. |