DUSO

DATA UNIT SET UP OPTIONS

INDICATES:

Data Unit Options for speed, format and data length.

DATE:

8/9/1990

BILLING:

CRIS

APPLICATIONS:

DMS-100, Data Service


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@H/DUSO OM.LEASED, SPD.300,
     DF.ASYN, DL.11, AA.E,
     RSD.E, TSD.E, LCLD.E
               or
I1   @@H/DUSO OM.HAYES, SPD.1200,
     DF.SYNC, AA.E, RSD.E,
     TSD.D, LCLD.E

DMS  -100
I1   @@H/DUSO CLASSDU.LSEXT,
     DOWNLOAD.Y, CLOCKSRC.E,
     DUPLEX.F

REFERENCES:

  1. Northern Telecom Practice 297-2101-310.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

6

116

Element: 1

Set Up Attributes

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

4

No

No

Code Set:

CodeMeaning
OMOperating Mode
SPDSpeed
DFData Format
DLData Length
AAAuto Answer
RSDReceive Space Disconnect
TSDTransmit Space Disconnect
LCLDLoss of Carrier or Line Disconnect

Element: 2

Set Up Values

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

6

No

No

Data Parameters:

Data characteristics are locally developed.

Element: 3

Data Unit Options (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

6

8

No

No

Code Set:

CodeMeaning
CLASSDUClass of Data Unit
DOWNLOADDownload Data Unit Profile
CONFIGConfiguration
SYNCHROSynchronous/Asynchronous Transmission
CHARLENCharacter Length
CLOCKSRCClocking Source
DUPLEXDuplex
KEYBDIALKeyboard Dialing
KBDTYPType of Keyboard Dialing

Element: 4

Class of Data Unit Option Values (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

6

No

No

Code Set:

CodeMeaning
LSLow Speed Data Unit
HSHigh Speed Data Unit
MPModem Pool Data Unit
RMRack Mount
LSEXTLow Speed Loop Extended Data Unit
HSEXTHigh Speed Loop Extended Data Unit
CCUController Coax Unit
TCUTerminal Coax Unit
AILCAsynchronous Interface Line Card
DAVLCData Above Voice Line Card
OPENAny Class of Data Unit can operate on the loop.  Data Units run off default profiles.
MADOMeridian Asynchronous Data Option
MONMonitor Data Unit (Maintenance)
MILMilitary Data Unit
ISDNDUIntegrated Services Digital Network Data Unit

Element Rules:

Element required when code set CLASSDU on Element 3 is used.

Element: 5

Download Option Values (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

Element Rules:

Element required when code set DOWNLOAD on Element 3 is used.

Element: 6

Configuration Option Vlaues (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
DTEData Terminal
DCEModem

Element Rules:

Element required when code set CONFIG on Element 3 is used.

Element: 7

Transmission Option Values (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
AAsynchronous Transmission
SSynchronous Transmission

Element Rules:

Element required when code set SYNCHRO on Element 3 is used.

Element: 8

Character Length Option Values (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Data Parameters:

5-8

Element Rules:

Element required when code set CHARLEN on Element 3 is used. Element used with asynchronous only.

Element: 9

Clocking Source Option Values (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
IInternally derived clocking for data transmission
EExternally derived from customer's equipment

Element Rules:

Element required when code set CLOCKSRC on Element 3 is used. Element applies to synchronous only.

Element: 10

Duplex Option Values (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
FFull-duplex
HHalf-duplex

Element Rules:

Element required when code set DUPLEX on Element 3 is used.

Element: 11

Keyboard Dialing Option Value (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

Element Rules:

Element required when code set KEYBDIAL on Element 3 is used.

Element: 12

Type of Keyboard Dialing Values (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

5

No

No

Code Set:

CodeMeaning
SYMBSymbolic
HAYESHayes Compatible
SL1SL-1 Compatible

Element Rules:

Element required when code set KBDTYP on Element 3 is used.

Element: 13

Keyboard Prompts Indicator (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

7

7

No

No

Code Set:

CodeMeaning
PROMPTS

Element Rules:

Element required when code set SYMB on Element 12 is used.

Element: 14

Keyboard Prompts Value (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

Element: 15

Idle Timeout Indicator (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

6

6

No

No

Code Set:

CodeMeaning
IDLETOIdle Timeout

Element Rules:

Element required when code set AILC is used on Element 4.

Element: 16

Idle Timeout Value (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

1

No

No

Code Set:

CodeMeaning
0No Timeout
115 Minutes Timeout
230 Minutes Timeout
360 Minutes Timeout

No.

Element Combination

Series

Separator

1.

1 . 2

Yes

, SP

2.

3 . 4

No

3.

3 . 4 , SP 3 . 5 , SP 3 . 6 , SP 3 . 7 , SP 3 . 8 , SP 3 . 10 , SP 3 . 11 , SP 3 . 12 , SP 13 . 14

No

4.

3 . 4 , SP 3 . 5 , SP 3 . 6 , SP 3 . 7 , SP 3 . 8 , SP 3 . 10 , SP 3 . 11 , SP 3 . 12 , SP 15 . 16

No

5.

3 . 4 , SP 3 . 5 , SP 3 . 6 , SP 3 . 7 , SP 3 . 9 , SP 3 . 10

No

6.

3 . 4 , SP 3 . 5 , SP 3 . 6 , SP 3 . 7 , SP 3 . 9 , SP 3 . 10 , SP 3 . 11 , SP 3 . 12

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

D,O

D,O

I,O, C,T, D,E, X,R, M

I,O, C,T, D,E, R

I,O, C,T, D,E, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.