EML

EXPECTED MEASURED LOSS

INDICATES:

The expected measured loss when specified as an option on Switched Access service.

DATE:

10/11/2007

BILLING:

CABS

APPLICATIONS:

Access Service


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@A/TN 732 555-1234/EML 0.5T

               or

I1   @@A/TN 732 555-1234/EML +13.0T, -12.7R

FID RULES/CONSTRAINTS:

  1. EML and data are allowable as an option on FG A, B, C and D.
  2. X action code prohibited on Access Service orders.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

2

6

Element: 1

Expected Measured Loss

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

1

5

No

No

Data Parameters:

-1.0 thru -13.9
+0.0 thru +13.9
XNo level specified

Symbols:

Hyphen, Period, Plus Sign

Element Rules:

Period is used as a decimal point to indicate Decibel level in tenths.

Element: 2

Transmit/Receive Indicator

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
TTransmit - Level from the Local Exhange Carrier (LEC) to the Interexchange Carrier (IC) or End User
RReceive  - Level from the IC or End User to the LEC

No.

Element Combination

Series

Separator

1.

1  2

2

, SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

P

P

O

O

O

P

P

P

Action Codes

I,E

-

-

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

-

-

-


CRIS

CABS

Data Retention

No

Yes

Printed on CSR

No

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.