F2-F9

FACILITY 2 THRU FACILITY 9

INDICATES:

The facilities beyond the first segment of a transmission path.

DATE:

12/13/1990

BILLING:

CRIS and CABS

APPLICATIONS:

General Purpose


SECTION - POSITION

EXAMPLES

ASGM - LH

IF1  TRAN/CA 1801/PR 200/BP 300
     /TEA R123 PINE
IF1  REC/CA 1801/PR 201/BP 301
     /TEA R123 PINE
IF2  TRAN H/HCA 135W/PR 25
     /TEA INTERIOR WATERS BLOCK
IF2  REC H/HCA 135W/PR 26
     /TEA INTERIOR WATERS BLOCK
            or
IF1  /CA 10/PR 101/BP 10
     /TEA 16 OAK
IF2  CFA

FID RULES/CONSTRAINTS:

  1. This FID is entered in the Outside Plant Facilities Subset.
  2. T, F, and X order types prohibited for Access Service application.

SERVICE ORDER ACTIVITY NOTES:

  1. These segments start at the "out" cable count of the preceding facility segment cross-connection point and end at the "in" termination of the next cross-connection point.  If there is no other interface, it ends at the termination in the distribution cable.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

ASGM - LH

Optional

Alphabetic

0

6

Element: 1

Pair Instruction

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

4

No

No

Code Set:

CodeMeaning
CFACall for assignment (Pre-completion copy only)
RECPair used for receiving (4-wire circuits)
TRANPair used for transmission (4-wire curcuits)

Element: 2

Non-Inventoried Cable

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
BBlock cable
HHouse cable
LLocal cable
NNarrative cable
SSpecial cable

Element Rules:

This entry is only used for location situations that require an indication that non-inventoried cable is used as a facility segment.

No.

Element Combination

Series

Separator

1.

1

No

2.

1 SP 2

No

3.

2

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: ASGM - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

P

O

P

P

Action Codes

I

I

I,O

O

I,O

-

I,O

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.