FAFI

FEATURE ACTIVATOR FEATURE INDICATOR

INDICATES:

The feature activator and feature indicator values.

DATE:

8/1/1996

BILLING:

CRIS

APPLICATIONS:

EWSD, ISDN BRI, TL1


SECTION - POSITION

EXAMPLES

S&E - LH

TL1; EWSD, APS 11.0
IFAFI|A FA 12.CFS3, 13.DROP;
      FI 12.CFS3

          or

IFAFI|C FAFI 1.ARA, 2.CNAB

S&E - FL

TL1; EWSD, APS 11.0
I1    @@W/TSPD 908 555-4444-01
      /TN 555-4444/PN 555-4444
      /DSNA 10.IBZD.33567..NJ
      /FAFI A

              or

Terminal (TSP) Application
I1    @@W/TSPD 908 555-6666-01
      /TN 555-6666/PN 555-6666
      /DSNA 10.IBZD.56777..NJ
      /USID 1/TTYT EKTS.Y; CACH.Y
      /FAFI FA 12.CFBL, 13.CFDA;
      FI 12.CFBL

I1    @@A/TN 555-6666/PN 555-6666
      /DSNA 10.IBZD.56777..NJ/CFW
      CFBL UNRES, CFNB.555 3322;
      CFDA UNRES, CFND.5553469/BCN
      SP 3AU/DNR 1/KEY 1 NUMC 3/CAPI
      1.1, 2.2, 3.3/TSPD 908 555-6666-01

              or

Directory Number Call Type (DNCT) Application
I1    @@A/TN 555-8888/PN 555-8888
      /DSNA 10.IBZD.33666..NJ/ACBK
      UNRES/FAFI FAFIDN 12.ACBA1

FID RULES/CONSTRAINTS:

  1. SERIES AND RANGE ENTRIES - PROCESSING
    Series and Range processing on this FID is not appropriate, since the USOC logical line will never carry a quantity greater than 1.

REFERENCES:

  1. TL1
    TR-NWT-000199, TSP View, Keywords FA, FAFI, FAFIHMBS, FAFISHS, FAHMBS, FASHS, FI, FIHMBS, FISHS; TSPDNCT View, Keywords FADN, FAFIDN, FIDN.
  2. EWSD
    Siemens, Stromberg-Carlson, 1090-00010 Commands CR TSP, EDIT TSP, 0770-00010 Keywords FA, FI.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - LH

Required

Alphanumeric

8

80

Element: 1

Feature Activator Feature Indicator (FAFI) Identifier (TL1; EWSD, APS 11.0)

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

1

3

No

No

Data Parameters:

A-ZZZ

Element: 2

FAFI Feature Name (TL1; EWSD, APS 11.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

6

No

No

Code Set:

CodeMeaning
FAFeature Activator (TL1; EWSD, APS 11.0)
FIFeature Indicator (TL1; EWSD, APS 11.0)
FAFIFeature Activator Feature Indicator (TL1)
FADNFeature Activator Per DN/CT (Directory Number/Call Type) (TL1; EWSD, APS 11.0)
FIDNFeature Indicator Per DN/CT (Directory Number/Call Type) (TL1; EWSD, APS 11.0)
FAFIDNFeature Activator Feature Indicator Per DN/CT (Directory Number/Call Type) (TL1)

Element Rules:

Code sets FADN, FIDN, and FAFIDN are only allowed following a Bearer Service USOC, i.e., @@A.
Code sets FA, FI, and FAFI are only allowed following the TSP (Terminal Service Profile) USOC, i.e., @@W.
Code sets FA and FI are mutually exclusive with code set FAFI.
Code sets FADN and FIDN are mutually exclusive with code set FAFIDN.

Element: 3

FAFI Hunt Make Busy Feature Name (TL1)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

6

8

No

No

Code Set:

CodeMeaning
FAHMBSFeature Activator Hunt Make Busy Application Set
FIHMBSFeature Indicator Hunt Make Busy Application Set
FAFIHMBSFeature Activator Feature Indicator Hunt Make Busy Application Set

Element: 4

FAFI Stop Hunt Feature Name (TL1)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

5

7

No

No

Code Set:

CodeMeaning
FASHSFeature Activator Stop Hunt Application
FISHSFeature Indicator Stop Hunt Application
FAFISHSFeature Activator Feature Indicator Stop Hunt Application

Element: 5

FAFI Feature Identifier Attribute Name (TL1; EWSD, APS 11.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

5

No

No

Data Parameters:

1-16383

Element: 6

FAFI Make Busy Or Stop Hunt Application Set Attribute Value (TL1)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

0-99

Element: 7

FAFI Feature Name Attribute Value (TL1; EWSD, APS 11.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

8

No

No

Element Rules:

TL1
The Master Feature List is defined in TR-NWT-000199, Issue 2, Supplement 1, A.3.3.1.
EWSD
The Master Feature List is defined in Siemens, Stromberg-Carlson 1090-00010 CR TSP and Edit TSP Commands.

No.

Element Combination

Series

Separator

1.

1 SP [ 2 SP [ 5 . 7 , SP ] ; SP ]

No

2.

1 SP [ 2 SP [ 5 . 7 , SP ] ; SP ] ; SP [ 3 . [ 5 . 6 . 7 , SP ] ; SP ]

No

3.

1 SP [ 2 . [ 5 . 7 , SP ] ; SP ] ; SP [ 3 . [ 5 . 6 . 7 , SP ] ; SP ] ; SP [ 4 . [ 5 . 6 . 7 , SP ] ; SP ]

No

4.

1 SP [ 2 SP [ 5 . 7 , SP ] ; SP ] ; SP [ 4 . [ 5 . 6 . 7 , SP ] ; SP ]

No

5.

1 SP [ 3 . [ 5 . 6 . 7 , SP ] ; SP ]

No

6.

1 SP [ 3 . [ 5 . 6 . 7 , SP ] ; SP ] ; SP [ 4 . [ 5 . 6 . 7 , SP ] ; SP ]

No

7.

1 SP [ 4 . [ 5 . 6 . 7 , SP ] ; SP ]

No


SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

1

76

Element: 1

Feature Activator Feature Indicator (FAFI) Identifier (TL1; EWSD, APS 11.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

3

No

No

Data Parameters:

A-ZZZ

Element: 2

FAFI Feature Name (TL1; EWSD, APS 11.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

6

No

No

Code Set:

CodeMeaning
FAFeature Activator (TL1; EWSD, APS 11.0)
FIFeature Indicator (TL1; EWSD, APS 11.0)
FAFIFeature Activator Feature Indicator (TL1)
FADNFeature Activator Per DN/CT (Directory Number/Call Type) (TL1; EWSD, APS 11.0)
FIDNFeature Indicator Per DN/CT (Directory Number/Call Type) (TL1; EWSD, APS 11.0)
FAFIDNFeature Activator Feature Indicator Per DN/CT (Directory Number/Call Type) (TL1)

Element Rules:

Code sets FADN, FIDN, and FAFIDN are only allowed following a Bearer Service USOC, i.e. @@A.
Code sets FA, FI, and FAFI are only allowed following the TSP (Terminal Service Profile) USOC, i.e. @@W.
Code sets FA and FI are mutually exclusive with code set FAFI.
Code sets FADN and FIDN are mutually exclusive with code set FAFIDN.

Element: 3

FAFI Hunt Make Busy Attribute Name (TL1)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

6

8

No

No

Code Set:

CodeMeaning
FAHMBSFeature Activator Hunt Make Busy Application Set
FIHMBSFeature Indicator Hunt Make Busy Application Set
FAFIHMBSFeature Activator Feature Indicator Hunt Make Busy Application Set

Element: 4

FAFI Stop Hunt Feature Name (TL1)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

5

7

No

No

Code Set:

CodeMeaning
FASHSFeature Activator Stop Hunt Application
FISHSFeature Indicator Stop Hunt Application
FAFISHSFeature Activator Feature Indicator Stop Hunt Application

Element: 5

FAFI Feature Identifier Attribute Name (TL1; EWSD, APS 11.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

5

No

No

Data Parameters:

1-16383

Element: 6

FAFI Make Busy Or Stop Hunt Application Set Attribute Value (TL1)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

0-99

Element: 7

FAFI Feature Name Attribute Value (TL1; EWSD, APS 11.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

8

No

No

Element Rules:

TL1
The Master Feature List is defined in TR-NWT-000199, Issue 2, Supplement 1, A.3.3.1.
EWSD
The Master Feature List is defined in Siemens, Stromberg-Carlson 1090-00010 CR TSP and Edit TSP Commands

No.

Element Combination

Series

Separator

1.

1

No

2.

2 SP [ 5 . 7 , SP ]

Yes

; SP

3.

[ 2 SP [ 5 . 7 , SP ] ; SP ] ; SP [ 3 . [ 5 . 6 . 7 , SP ] ; SP ]

No

4.

[ 2 SP [ 5 . 7 , SP ] ; SP ] ; SP [ 3 . [ 5 . 6 . 7 , SP ] ; SP ] ; SP [ 4 . [ 5 . 6 . 7 , SP ] ; SP ]

No

5.

[ 2 SP [ 5 . 7 , SP ] ; SP ] ; SP [ 4 . [ 5 . 6 . 7 , SP ] ; SP ]

No

6.

3 . [ 5 . 6 . 7 , SP ]

Yes

; SP

7.

[ 3 . [ 5 . 6 . 7 , SP ] ; SP ] ; SP [ 4 . [ 5 . 6 . 7 , SP ] ; SP ]

No

8.

4 . [ 5 . 6 . 7 , SP ]

Yes

; SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D,

I,O, C,T

I,O, C,T

I,O

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D,

I,O, C,T

I,O, C,T

I,O

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.