FCSZ

FLOW CONTROL SIZE - PACKET SERVICE

INDICATES:

The throughput size, packet size and window size for Packet Service.

DATE:

9/15/2005

BILLING:

CRIS and CABS

APPLICATIONS:

DMS-100, ISDN BRI, Public Packet Switched Network (PPSN)


SECTION - POSITION

EXAMPLES

S&E - FL

Prior to NA007
I1   @@H/CLS 10.QSHK.123456..NJ
     /FCSZ TC.R5 T5; PS.R256 T256;
     WS.R5 T5/TWN T.Y, W.Y, P.Y

DMS PH NA007
I1   @@H/CLS 10.QSHK.123456..NJ/DTN 732
     555-1234/DSNA 10.IBMX.234567..NJ
     /FCSZ DTCA.Y, IDTCA.150, ODTCA.300;
     NDPS.Y, IMPS.32, OMPS.128; NDWS.Y,
     IPLWS.28, OPLWS.28/TWN TCN, FCPN


                 or

I1   @@H/CLS 10.QSHK.123456..NJ/DTN 732
     555-1234/FCSZ DTCA.N; NDPS.N;
     NDWS.N/TWN TCN, FCPN

FID RULES/CONSTRAINTS:

  1. ISDN Packet Switched Bearer Service
    Section:  S&E      Position:  FL

    For mechanized flow-through, FID may be entered on the  FEATURE  USOC logical line if CLS appears on the same logical line.
  2. T, F, and X order types prohibited for Access Service application.
  3. X action code prohibited on Access Service orders.

REFERENCES:

  1. DMS-100 (Prior to NA007)
    NORTEL Practice 297-2421-310.
  2. DMS PH (NA007)
    NORTEL Preliminary Document, AR2133, Data Network Address (DNA) Parameters, IMPS, OMPS, IDTCA, ODTCA, IPLWS, OPLWS, DTCA, NDPS, NDWS.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

5

57

Element: 1

Data Network Address Feature Name (DMS PH NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
DTCADefault Throughput Class Assignment
NDPSNon-Standard Default Packet Size
NDWSNon-Standard Default Window Size

Element: 2

Data Network Address Feature Name Value (DMS PH NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

Element: 3

Data Network Address Parameters

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

5

No

No

Code Set:

CodeMeaning
TCThroughput Class (Prior to NA007)
PSPacket Size (Prior to NA007)
WSWindow Size (Prior to NA007)
IMPSIncoming Maximum Packet Size (NA007)
OMPSOutgoing Maximum Packet Size (NA007)
IDTCAIncoming Default Throughput Class Assignment (NA007)
ODTCAOutgoing Default Throughput Class Assignment (NA007)
IPLWSIncoming Packet Layer Window Size (NA007)
OPLWSOutgoing Packet Layer Window Size (NA007)

Element: 4

Send/Receive Indicator (Prior to NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
RReceive
TTransmit

Element: 5

Throughput Class Parameter

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

5

No

No

Data Parameters:

Prior to NA007
3 - 13
NA007
75, 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 48000, 64000

Element Rules:

DMS PH (Prior to NA007)
Element is required entry when code set for element one (1) is TC.
DMS PH (Prior to NA007)
The switch default is 12 for Link Access Procedure Balanced (LAPB) and 10 for Link Access Protocol for D Channel ISDN (LAPD).

Element: 6

Packet Size Parameters

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

2

3

No

No

Data Parameters:

16, 32, 64, 128, 256, 512

Element Rules:

DMS PH (Prior to NA007)
Element is required entry when code set on element one (1) is PS.
DMS PH (Prior to NA007)
The switch default is 256.

Element: 7

Window Size Parameters

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

1-7(Prior to NA007)
1-127(NA007)

Element Rules:

DMS PH (Prior to NA007)
Element is required entry when code set on element one (1) is WS.
The switch default is 2.

No.

Element Combination

Series

Separator

1.

1 . 2

Yes

; SP

2.

1 . 2 SP 3 . 5 ; SP [ 1 . 2 ; SP ]

No

3.

1 . 2 , SP [ 3 . 5 , SP ] ; SP 1 . 2 , SP [ 3 . 6 , SP ] ; SP 1 . 2 , SP [ 3 . 7 , SP ]

No

4.

[ 1 . 2 ; SP ] SP 3 . 6 ; SP 1 . 2 SP 3 . 7

No

5.

[ 1 . 2 ; SP ] SP 3 . 7

No

6.

3 . 4  5

No

7.

3 . 4  5 ; SP 3 . 4  6

No

8.

3 . 4  5 ; SP 3 . 4  6 ; SP 3 . 4  7

No

9.

3 . 4  5 ; SP 3 . 4  6 ; SP 3 . 4  7 SP 4  7

No

10.

3 . 4  5 ; SP 3 . 4  6 SP 4  6

No

11.

3 . 4  5 ; SP 3 . 4  6 SP 4  6 ; SP 3 . 4  7

No

12.

3 . 4  5 ; SP 3 . 4  6 SP 4  6 ; SP 3 . 4  7 SP 4  7

No

13.

3 . 4  5 ; SP 3 . 4  7

No

14.

3 . 4  5 ; SP 3 . 4  7 SP 4  7

No

15.

3 . 4  5 SP 4  5

No

16.

3 . 4  5 SP 4  5 ; SP 3 . 4  6

No

17.

3 . 4  5 SP 4  5 ; SP 3 . 4  6 ; SP 3 . 4  7

No

18.

3 . 4  5 SP 4  5 ; SP 3 . 4  6 ; SP 3 . 4  7 SP 4  7

No

19.

3 . 4  5 SP 4  5 ; SP 3 . 4  6 SP 4  6

No

20.

3 . 4  5 SP 4  5 ; SP 3 . 4  6 SP 4  6 ; SP 3 . 4  7

No

21.

3 . 4  5 SP 4  5 ; SP 3 . 4  6 SP 4  6 ; SP 3 . 4  7 SP 4  7

No

22.

3 . 4  5 SP 4  5 ; SP 3 . 4  7

No

23.

3 . 4  5 SP 4  5 ; SP 3 . 4  7 SP 4  7

No

24.

3 . 4  6

No

25.

3 . 4  6 ; SP 3 . 4  7

No

26.

3 . 4  6 ; SP 3 . 4  7 SP 4  7

No

27.

3 . 4  6 SP 4  6

No

28.

3 . 4  6 SP 4  6 ; SP 3 . 4  7

No

29.

3 . 4  6 SP 4  6 ; SP 3 . 4  7 SP 4  7

No

30.

3 . 4  7

No

31.

3 . 4  7 SP 4  7

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, E,D, M,X, R

I,O, C,T, E,D, M,X, R

I,O, C,T, R

-

-

Other FIDs Required Logical Line

TWN

TWN

TWN

TWN

TWN

TWN

TWN

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.