FEA |
FEATURES |
INDICATES: |
The lines and other features of each key telephone in a key system. |
DATE: |
10/31/2014 |
BILLING: |
CRIS |
APPLICATIONS: |
General Purpose |
SECTION - POSITION |
EXAMPLES |
S&E - FL |
|
Six button telephone with three Identification Format |
FID RULES/CONSTRAINTS: |
|
SERVICE ORDER ACTIVITY NOTES: |
|
SECTION - POSITION |
APPEARANCE |
MODE |
MIN |
MAX |
S&E - FL |
Required |
Alphanumeric |
3 |
72 |
Element: 1 |
Feature Indicator |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Required |
Alphabetic |
1 |
4 |
No |
No |
Code Set: |
||||||||||||||||||||||||||||||||||||||||||||||||||
|
Element Rules: |
All the Feature Indicators, except K and PA, must be associated with additional information as described in the following elements. |
Element: 2 |
Numbering Plan Area Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
3 |
3 |
No |
No |
Reference: |
See iconectiv LERG Routing Guide for complete list. |
Element Rules: |
NPA is required when it cannot be derived first from the NPA previously entered on the same logical line, second from the fielded TN, or third from the fielded EX in the Identification section. |
Element: 3 |
Line Identification Central Office Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
3 |
4 |
No |
No |
Symbols: |
At Sign, Plus Sign |
Reference: |
See iconectiv LERG Routing Guide for complete list. |
Element Rules: |
Required when Telephone Number Format is used with Feature Indicators P, I, H, L, W, M, PM, IM, HM, LM, WM, MI, MV and COML. |
Element: 4 |
Line Identification Line Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
4 |
5 |
No |
No |
Data Parameters: |
||
|
Symbols: |
At Sign, Plus Sign |
Element Rules: |
Required when Telephone Number Format is used with Feature Indicators P, I, H, L, W, M, PM, IM, HM, LM, WM, MI, MV and COML. |
Element: 5 |
Line Identification Prefix |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
3 |
No |
No |
Symbols: |
At Sign, Plus Sign |
Reference: |
See BR 795-402-100 for complete list. |
Element: 6 |
Line Identification Service Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
2 |
3 |
No |
No |
Symbols: |
At Sign, Plus Sign |
Reference: |
See BR 795-402-100 for complete list. |
Element Rules: |
Required when Circuit Number Format is used with Feature Indicators P, I, H, L, W, M, PM, IM, HM, LM, WM, MI, MV and COML. |
Element: 7 |
Line Identification First Modifier |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
2 |
No |
No |
Data Parameters: |
||
|
Symbols: |
At Sign, Plus Sign |
Element Rules: |
Required when Circuit Number Format is used with Feature Indicators P, I, H, L, W, M, PM, IM, HM, LM, WM, MI, MV and COML. |
Element: 8 |
CLCI Second Modifier |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic or Numeric |
1 |
1 |
No |
No |
Reference: |
See BR 795-402-100 for complete list. |
Element: 9 |
Line Identification Serial Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
7 |
No |
No |
Data Parameters: |
||
|
Symbols: |
At Sign, Plus Sign |
Element Rules: |
Required when Circuit Number Format is used with Feature Indicators P, I, H, L, W, M, PM, IM, HM, LM, WM, MI, MV and COML. |
Element: 10 |
Line Identification Suffix |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
4 |
No |
No |
Data Parameters: |
||
|
Symbols: |
At Sign, Plus Sign |
Element: 11 |
Line Identification Assigning Company Identification |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
2 |
5 |
No |
No |
Symbols: |
At Sign, Plus Sign |
Reference: |
See BR 751-100-112 for complete list. |
Element Rules: |
Required when Circuit Number Format is used with Feature Indicators P, I, H, L, W, M, PM, IM, HM, LM, WM, MI, MV and COML. |
Element: 12 |
Line Identification Segment |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
4 |
No |
No |
Data Parameters: |
||||||
|
Symbols: |
At Sign, Plus Sign |
Element: 13 |
Line Identification Extension Number or Trunk Identifier |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
2 |
6 |
No |
No |
Data Parameters: |
||||||||||||||||
|
Symbols: |
At Sign, Plus Sign |
Element Rules: |
||
|
Element: 14 |
Line Identification PX Station Line Indicator |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
2 |
2 |
No |
No |
Code Set: |
||||
|
Symbols: |
At Sign, Plus Sign |
Element Rules: |
Required when PBX Station Line Number Format is used with Feature Indicators P, I, H, L, W, M, PM, IM, HM, LM, WM, MI, MV and COML. |
Element: 15 |
Line Identification PX Station Line Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
4 |
No |
No |
Data Parameters: |
||
|
Symbols: |
At Sign, Plus Sign |
Element Rules: |
Required when PBX Station Line Number Format is used with Feature Indicators P, I, H, L, W, M, PM, IM, HM, LM, WM, MI, MV and COML. |
Element: 16 |
Line Identification Terminal Number Multiline Group |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
5 |
No |
No |
Data Parameters: |
||||||
|
Symbols: |
At Sign, Plus Sign |
Element Rules: |
||
|
Element: 17 |
Line Identification Intercommunication Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
3 |
No |
No |
Data Parameters: |
||
|
Symbols: |
At Sign, Plus Sign |
Element Rules: |
Required when Intercommunications Number Format is used with Feature Indicators P, I, H, L, W, M, PM, IM, HM, LM, WM, MI, MV and COML. |
Element: 18 |
Line Identification Simple Numbering Plan Area Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
5 |
No |
No |
Data Parameters: |
||
|
Symbols: |
At Sign, Plus Sign |
Element Rules: |
Required when Simple Numbering Plan Number Format is used with Feature Indicators P, I, H, L, W, M, PM, IM, HM, LM, WM, MI, MV and COML. |
Element: 19 |
Line Identification Extra Number (Alphanumeric Format)-Number Group |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
2 |
No |
No |
Data Parameters: |
||||
|
Element Rules: |
Required when Extra Number Format is used with Feature Indicators P, I, H, L, W, M, PM, |
Element: 20 |
Line Identification Extra Number (Alphanumeric Format)-Number Group Designation |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
2 |
2 |
No |
No |
Data Parameters: |
||
|
Element Rules: |
Required when Extra Number Format is used with Feature Indicators P, I, H, L, W, M, PM |
Element: 21 |
Line Identification Extra Number (Numeric Format) |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
4 |
4 |
Yes |
Yes |
Data Parameters: |
||
|
Element Rules: |
Required when Extra Number Format is used with Feature Indicators P, I, H, L, W, M, PM |
Element: 22 |
Line Designation |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
1 |
No |
No |
Element Rules: |
This element is used with Feature Indicator COML when more than one intercom line appears at a station. |
Element: 23 |
Station Identification |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
1 |
2 |
Yes |
No |
Element Rules: |
This element is used with Feature Indicators S, SX, Z, C, E and T. When there is more than one signaling circuit per receiving station and it is necessary to indicate the signaling with which a button works, a number beginning with 2 follows the alphabetic entry. In this case, there is no separator between elements 4 and 5. |
Element: 24 |
Descriptive Information |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
66 |
No |
No |
Symbols: |
Ampersand, Left Parenthesis, Right Parenthesis, Space |
Element Rules: |
|||
|
Element: 25 |
Paging Zone Identification |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic or Numeric |
1 |
3 |
Yes |
No |
Code Set: |
||||||
|
Element Rules: |
||
|
Element: 26 |
Paging Zone Override |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
2 |
3 |
No |
No |
Code Set: |
||||||
|
Element Rules: |
||
|
No. |
Element Combination |
Series |
Separator |
1. |
1 SP 2 SP 3 - 4 |
No |
|
2. |
1 SP 3 - 4 |
No |
|
3. |
1 SP 5 . 6 7 8 SP 2 SP 3 - 4 |
No |
|
4. |
1 SP 5 . 6 7 8 SP 2 SP 3 - 4 . 12 |
No |
|
5. |
1 SP 5 . 6 7 8 SP 2 SP 3 - 4 . 13 . 12 |
No |
|
6. |
1 SP 5 . 6 7 8 . 9 . 10 . 11 |
No |
|
7. |
1 SP 5 . 6 7 8 . 9 . 10 . 11 . 12 |
No |
|
8. |
1 SP 5 . 6 7 8 . 9 . 11 |
No |
|
9. |
1 SP 5 . 6 7 8 . 9 . 11 . 12 |
No |
|
10. |
1 SP 6 7 8 SP 2 SP 3 - 4 |
No |
|
11. |
1 SP 6 7 8 SP 2 SP 3 - 4 . 12 |
No |
|
12. |
1 SP 6 7 8 SP 2 SP 3 - 4 . 13 . 12 |
No |
|
13. |
1 SP 6 7 8 . 9 . 10 . 11 |
No |
|
14. |
1 SP 6 7 8 . 9 . 10 . 11 . 12 |
No |
|
15. |
1 SP 6 7 8 . 9 . 11 |
No |
|
16. |
1 SP 6 7 8 . 9 . 11 . 12 |
No |
|
17. |
1 SP 14 SP 15 |
No |
|
18. |
1 SP 16 |
No |
|
19. |
1 SP 17 |
No |
|
20. |
1 SP 18 |
No |
|
21. |
1 SP 19 20 |
No |
|
22. |
1 SP 21 |
No |
ORDER TYPE/ACTION CODE/FID RELATIONSHIPS |
Order Section - Position: S&E - FL
|
Order Type |
N |
T |
F |
D |
C |
R |
X |
P |
A |
Presence |
O |
O |
O |
O |
O |
O |
O |
O |
P |
Action Codes |
I,E |
I,E |
O,D |
O,D |
I,O, C,T, M,X, D,E, R |
I,O, C,T, M,X, D,E, R |
I,O, C,T, R |
I |
- |
CRIS |
CABS |
|
Data Retention |
No |
No |
Printed on CSR |
No |
No |
Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure. |
iconectiv Confidential - Restricted Access This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv. |
Licensed Material - Property of iconectiv Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv. |