FNC

FEATURE NAME - CUSTOMER CHANGEABLE

INDICATES:

A list of one or more customer changeable switch features and when required, associated feature attributes.

DATE:

3/2/2006

BILLING:

CRIS and CABS

APPLICATIONS:

1AESS, 5ESS, DMS-100, EWSD


SECTION - POSITION

EXAMPLES

S&E - LH

1AESS
FNC  1-CPG 30, SCG 12, CFN 266-4010

5ESS
FNC  1-*IDCTX1 IDGPNM.EXXON1; *TDARS;
     *ARC ARGPNAME.YORK1, DIALPLN.ODP

EWSD
FNC  1-CFV; TWC; UPSPD30

DMS-100
FNC  1-CFB; CWI; SC30

         or

FNC  1-MWI.SPD; CAR.Y; KSH.N

S&E - FL

I1   @@A/TN 732 555-1234/FNC 1

I1   @@A/TN 732 555-1234/FNC 5; 8

1AESS
I1   @@A/TN 732 555-1234/FNC CHD;
     CWT; 3WC; CFBL CFN 555-6777

5ESS
I1   @@A/TN 732 555-1234/FNC *IDCTX1
     IDGPNM.EXXON1; *TDARS; *ARC
     ARGPNAME.YORK1, DIALPLN.ODP

FID RULES/CONSTRAINTS:

  1. Element 2 and the combination of elements 3 and 5 may appear in any sequence of multiple entries.
  2. SERIES AND RANGE ENTRIES - PROCESSING
    Service Order Analysis and Control System (SOAC) should process series and range data entries using the DUPLICATE algorithm.

SERVICE ORDER ACTIVITY NOTES:

  1. FID may be used to indicate the provisioning of features per directory number when a customer rearrangement system, i.e. CCRS, is initially loaded.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - LH

Required

Alphanumeric

3

36

Element: 1

Feature List Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

3

No

No

Data Parameters:

1-999

Element: 2

Feature Name (5ESS, DMS-100, EWSD, 1AESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

8

Yes

No

Symbols:

Asterisk

Reference:

For preconstructed features for 5ESS, refer to Lucent Technologies 235-118-257 for complete list.

Element Rules:

5ESS
Lucent has defined most of the popular assignable service features, which are referred to as “pre-constructed” features and are identified on a FID by a mandatory leading asterisk “*”.  Additionally, system administrators are able to locally customize additional assignable features, which are referred to as “constructible” features.  Constructible features are locally developed, do not contain a leading asterisk and have 1-8 character feature names.  The Feature field is used to define both “pre-constructed” and “constructible” types of features.

This element is not restricted to preconstructed features.
Semicolon space is used as series separator.

Element: 3

Attribute Name (5ESS, DMS-100, EWSD, 1AESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

10

Yes

No

Element: 4

Attribute or Feature Value (5ESS, DMS-100, EWSD)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

12

No

No

Element: 5

Attribute Value (1AESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

8

No

No

Data Parameters:

1-99999999

Symbols:

Hyphen

No.

Element Combination

Series

Separator

1.

1 - 2

No

2.

1 - [ 2 SP 3 ; SP ]

No

3.

1 - [ 2 SP [ 3 . 4 , SP ] ; SP ]

No

4.

1 - [ 2 SP [ 3 SP 5 , SP ] ; SP ]

No

5.

1 - [ 2 . 4 ; SP ]

No

6.

1 - [ 3 SP 5 , SP ]

No

7.

1 - [ [ 3 SP 5 , SP ] ; SP 2 , SP ]

No


SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

1

32

Element: 1

Feature List Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

3

Yes

Yes

Data Parameters:

1-999

Element Rules:

Semicolon space is the series separator.

Element: 2

Feature Name (5ESS, DMS-100, EWSD, 1AESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

8

Yes

No

Symbols:

Asterisk

Reference:

For preconstructed features for 5ESS, refer to Lucent Technologies 235-118-257 for complete list.

Element Rules:

5ESS
Lucent has defined most of the popular assignable service features, which are referred to as “pre-constructed” features and are identified on a FID by a mandatory leading asterisk “*”.  Additionally, system administrators are able to locally customize additional assignable features, which are referred to as “constructible” features.  Constructible features are locally developed, do not contain a leading asterisk and have 1-8 character feature names.  The Feature field is used to define both “pre-constructed” and “constructible” types of features.

This element is not restricted to preconstructed features.
Semicolon space is the series separator.

Element: 3

Attribute Name (5ESS, DMS-100, EWSD, 1AESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

10

Yes

No

Element Rules:

5ESS
When Element 3 appears, Element 2 must also appear.
DMS-100 and 1AESS
When Element 3 appears, Element 2 is optional.

Element: 4

Attribute or Feature Value (5ESS, DMS-100, EWSD)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

12

Yes

No

Element: 5

Attribute Value (1AESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

8

No

No

Data Parameters:

1-99999999

Symbols:

Hyphen

No.

Element Combination

Series

Separator

1.

1

Yes

; SP

2.

2

Yes

; SP

3.

2 SP 3

Yes

; SP

4.

2 SP [ 3 . 4 , SP ]

Yes

; SP

5.

2 SP [ 3 SP 5 , SP ]

Yes

; SP

6.

2 . 4

Yes

; SP

7.

3 SP 5

Yes

, SP

8.

[ 3 SP 5 , SP ] ; SP 2

Yes

, SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

P

P

O

P

P

P

P

Action Codes

I

I

-

-

I

-

-

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No

Order Section - Position: S&E - FL

 

Please refer to S&E - LH for Order Type, Action Code, and FID relationships.




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.