FS

FAST SELECT OPTIONS

INDICATES:

The fast select options available to X.25, X.75 and Asynchronous Packet Service.

DATE:

7/7/2005

BILLING:

CRIS and CABS

APPLICATIONS:

5ESS, Access Service, DMS-100, EWSD, EWSP, ISDN BRI, Public Packet Switched Network (PPSN), TL1


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@H/CLS 10.QSHX.123456..NJ
     /DTN 732 555-1234/FS IB AY



5ESS
I1   @@HAY/CLS 10.QSHX.123456..NJ
     /DTN 732 555-1234/FS

DMS PH (Prior to NA007)
I1   @@H/CLS 10.QSHX.123456..NJ
     /DTN 732 555-1234/FS IF.Y

DMS PH (NA007)
I1   @@H/CLS 10.QSHX.123456..NJ
     /DTN 732 555-1234/DSNA
     10.IBMX.234567..NJ/FS FSA.Y

DPN - PH
I1   @@H/CLS 10.QSHX.123456..NJ
     /DTN 732 555-1234
     /FS OFU.Y, OFR.N, OFRO.N

TL1 ISDN
I1   @@H/CLS 10.QSHX.123456..NJ
     /DTN 732 555-1234/FS FSA

EWSP ISDN
I1   @@H/CLS 10.QSHX.123456..NJ
     /DTN 732 555-1234/DSNA
     10.IBMX.234567..NJ/FS FS.NO,
     FSAC.NO

ISDN-EWSD, APS 12.0
I1   @@H/CLS 10.QSHX.123456..NJ
     /DTN 732 555-1234/FS FS, FSA

FID RULES/CONSTRAINTS:

  1. T, F, and X order types prohibited for Access Service application.

SERVICE ORDER ACTIVITY NOTES:

  1. FID and data are floated on logical line with Fast Select option USOC. FID and data may also float on logical line with access line (speed) USOC.

REFERENCES:

  1. Refer to GR-301-CORE, Public Packet Switched Network Generic Requirements (PPSNGR), and TR-NPL-000011, Asynchronous Terminal and Host Interface Reference, for additional information.
  2. DMS-100 (Prior to NA007)
    NORTEL Practice 297-8001-808.
  3. DMS PH (NA007)
    NORTEL Preliminary Document, AR2133, Date Network Address (DNA), Option FSA.
  4. TL1
    TR-NWT-000199, DNCT View, Keyword FSA.
  5. EWSP
    Siemens, Stromberg-Carlson, Book P303, CML ADX25, Keywords FS, FSAC.
  6. EWSD
    Siemens, Strombers-Carlson, 0770-00010, Section 25, Keywords FS, FSAC; 1090-00010, Command EDIT PHPROF.
  7. 5ESS
    Lucent Technologies, 235-118-257, View 23.2, Keyword FSA.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Optional

Alphabetic

0

20

Element: 1

Initiate Fast Select Options

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
IBBoth Restricted And Unrestricted Response
IRRestricted Response
IUUnrestricted Response

Element Rules:

Required when access line is optioned to initiate fast select.

Element: 2

Accept Fast Select (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
AYAccept Fast Select Required
ANAccept Fast Select Not Required

Element Rules:

Element 2 is the only element valid for for 5ESS.
Required when access line is optioned to initiate fast select.

Element: 3

Initiate and Accept Restrict Only Fast Select Options (SL-10)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
RORestrict Only

Element: 4

Incoming Fast Select Calls Indicator (DMS-PH Prior to NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
IFIncoming Fast Select Calls (INFAST DMS-100 Prompt)

Element: 5

Incoming Fast Select Calls Response Indicator (DMS-PH Prior to NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

Element Rules:

The switch default is N.

Element: 6

Outgoing Fast Select Unrestricted Calls Indicator (DPN-PH)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
OFUOutgoing Fast Select Calls (OUTFASTUR DMS-100 Prompt)

Element: 7

Outgoing Fast Select Unrestricted Calls Response Indicator (DPN-PH)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

Element Rules:

The switch default is N.

Element: 8

Outgoing Fast Select Restricted Calls Indicator (DPN-PH)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
OFROutgoing Fast Select Restricted Calls (OUTFASTR DMS-100 Prompt)

Element: 9

Outgoing Fast Select Restricted Calls Response Indicator (DPN-PH)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

Element Rules:

The switch default is N.

Element: 10

Outgoing Fast Select Restricted Only Calls Indicator (DPN-PH)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
OFROOutgoing Fast Select Restricted Only Calls (OUTFASTRO DMS-100 Prompt)

Element: 11

Outgoing Fast Select Restricted Only Response Indicator (DPN-PH)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

Element Rules:

The switch default is N.

Element: 12

Fast Select Options Indicator (EWSP)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

4

No

No

Code Set:

CodeMeaning
FSFast Select Allowed
FSACFast Select Accepted

Element: 13

Fast Select Options (EWSP)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

3

No

No

Code Set:

CodeMeaning
NONo
YESYes

Element Rules:

The switch defaults for FS and FSAC are YES.

Element: 14

Fast Select Options Attribute Name (TL1; EWSD, APS 12.0; DMS PH, NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

3

Yes

No

Code Set:

CodeMeaning
FSFast Select Allowed (EWSD, APS 12.0)
FSAFast Select Accepted (TL1; EWSD, APS 12.0; DMS PH, NA007)

Element: 15

Fast Select Options Attribute Value (DMS PH, NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

Element Rules:

The switch default is NO.

No.

Element Combination

Series

Separator

1.

1

No

2.

1 SP 2

No

3.

2

No

4.

3

No

5.

4 . 5

No

6.

6 . 7

No

7.

6 . 7 , SP 8 . 9

No

8.

6 . 7 , SP 8 . 9 , SP 10 . 11

No

9.

6 . 7 , SP 10 . 11

No

10.

8 . 9

No

11.

8 . 9 , SP 10 . 11

No

12.

10 . 11

No

13.

12 . 13

Yes

, SP

14.

14

Yes

, SP

15.

14 . 15

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, R

I,O, C,T, D,E, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.