FSO

FOREIGN SWITCHING OFFICE

INDICATES:

The switching entity used for a circuit termination.

DATE:

10/31/2014

BILLING:

CRIS and CABS

APPLICATIONS:

Access Service, Access Service Request (ASR), General Purpose, Local Competition, Number Portability


SECTION - POSITION

EXAMPLES

S&E - FL

I1    @@A/TN 732 555-1234/FSO 732 699

FID RULES/CONSTRAINTS:

  1. The FSO must be specified for a circuit when the switching entity cannot first be determined from the Primary Line Identifier or secondarily by the Local Serving Office (LSO) for that circuit or when the derived value would be incorrect, i.e. a switching entity other than that used for the circuit.
  2. The specified Switching Entity may be within the Local Serving Office or may be in a Foreign Location.
  3. Any working Central Office Code designation unique to that Switching Entity may be used.
  4. The FID FSO is required on all Access Service orders for WATS Access Line's (WAL) when served from a foreign office.
  5. T, F, and X order types prohibited for Access Service application.
  6. X action code prohibited on Access Service orders.

REFERENCES:

  1. ATIS/OBF-ASR-009, FSO field

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Numeric

3

7

Element: 1

Numbering Plan Area Code

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element Rules:

NPA is required when it cannot be derived first from the NPA previously entered on the same logical line, second from the fielded TN, or third from the fielded EX in the Identification section.

Element: 2

Central Office Code

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

No.

Element Combination

Series

Separator

1.

1 SP 2

No

2.

2

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, R,M, X

I,O, C,T, D,E, R,M, X

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.