FUE1-FUE3

FREE FORMAT UNBUNDLED NETWORK ELEMENT CIRCUIT IDENTIFICATION 1 THRU 3

INDICATES:

The non-American National Standards Institute (ANSI)  free format circuit identification provided by an external service provider for use in an electronic trouble administration process.

DATE:

10/27/2005

BILLING:

CRIS and CABS

APPLICATIONS:

Access Service, Local Competition


SECTION - POSITION

EXAMPLES

S&E - FL

IG1  CLS 12.TXXU.123456.1..NJ
     /UNE1 3.ACFU.987654..NJ
     /UNN1 FIRST TELCO
     /FUE1 1234ABC5678
     /FUN1 COMPANY ONE

            or

IG2  CKL 1-594 MARKET ST,
     NEWARK, NJ/LSO 732 5555
     /NCI 04DS9.15
     /UNE1 210 T1 19
     NWRKNJMKW99 NWRKNJMK
     /UNN1 COMM. EXPRESS
     /FUE1 1234ABC5678
     /FUN1 COMPANY TWO

            or

I1   @@A/TN 732 555-1234
     /UNE1 732 555-0000
     /UNN1 TELCO UNO
     /FUE1 1234ABC5678
     /FUN1 COMPANY THREE

FID RULES/CONSTRAINTS:

  1. T, F, and X order types prohibited for Access Service application.
  2. X action code prohibited on Access Service orders.

SERVICE ORDER ACTIVITY NOTES:

  1. This FID may be used to enable the exchange of trouble tickets between service providers.
  2. The FUE1-FUE3 and Free Format Unbundled Network Customer Name 1-3 (FUN1-FUN3) FIDs must be used in pairs, i.e., FUE1 and FUN1.
  3. When this FID appears in the Work Force Administration (WFA) product Network and Services Database (NSDB), it is used for service assurance coordination activities.
  4. The FUE1-FUE3 and FUN1-FUN3 FIDs are not allowed with the Unbundled Connection Point 1-6 (UCP1-UCP6) Line Sharing solution FID.
  5. The term "free format" identifies circuits which do not comply with ANSI standards and COMMON LANGUAGE format.
  6. When the circuit identification conforms to ANSI standards, the appropriate UNE1-UNE6 FID should be used.
  7. When  used in combination with FUN1-FUN3, Unbundled Network Element Circuit Identification 1-6 (UNE1-UNE6) and Unbundled Network Customer Name 1-6 (UNN1-UNN6), a maximum of six sequentially numbered pairs are allowed for the end-to-end circuit, i.e.,UNE1/UNN1, UNE2/UNN2, UNE3/UNN3, FUE1/FUN1, FUE2/FUN2, FUE3/FUN3.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

1

36

Element: 1

Free Format Unbundled Network Element Circuit Identification

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

1

36

No

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I, E

I, E

O, D

O, D

I, O, C, T, D, E, M, X, R

I, O, C, T, D, E, M, X, R

I, O, C, T, R

-

-

Other FIDs Required Logical Line

FUN1 - FUN3

FUN1 - FUN3

FUN1 - FUN3

FUN1 - FUN3

FUN1 - FUN3

FUN1 - FUN3

FUN1 - FUN3

-

-

Other FIDs Prohibited Logical Line

UCP1 - UCP6

UCP1 - UCP6

UCP1 - UCP6

UCP1 - UCP6

UCP1 - UCP6

UCP1 - UCP6

UCP1 - UCP6

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.