GAL

GROUP ADDRESS LIST

INDICATES:

The Switched Multimegabit Data Service (SMDS) addresses that are members of a specific Group Address list, and the optional Group Address screening type.

DATE:

10/31/2014

BILLING:

CRIS and CABS

APPLICATIONS:

FETEX-150, Switched Multimegabit Data Service (SMDS)


SECTION - POSITION

EXAMPLES

S&E - LH

Entry with Series and Range
IGAL 1-908 555-0601-0615, 201 674-9987,
     673-2101-2203, 212 445-1010

S&E - FL

I1   @@H/CLS 10.QSXX.123456..NJ
     /DTN 732 555-1234/GAD
     /DSNA 10.QCXX.123456..NJ
I1   @@V/CLS 10.QSXX.123456..NJ
     /DTN 732 555-1234/GAL 1

             or

I1   @@V/CLS 10.QSXX.123456..NJ
     /DTN 732 555-1234/GAL 908
     555-0601-0615, 201 674-9987,
     673-2101-2203, 212 445-1010

FID RULES/CONSTRAINTS:

  1. T, F, and X order types prohibited for Access Service application.
  2. X action code prohibited on Access Service orders.
  3. To initiate a mechanized SOAC/MAS (Service Order Analysis and Control/Memory Administration System) flow through, this FID must appear on the assignable USOC logical line.

REFERENCES:

  1. Fujitsu, Translation Guide, ES19X-1516-M72, keywords IADR, GASTYP.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - LH

Required

Alphanumeric

10

35

Element: 1

Group Addressing Identifier

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

10

No

No

Data Parameters:

1-9999
or
10 digits in the form of NPANXXXXXX

Element Rules:

There is a one to one correlation between the GAD Group Addressing Identifier and the value of this element. The GAL Group Addressing Identifier equals the GAD Group Addressing Identifier that is assigned to a specific DTN.

Element: 2

Group Address List Screening Type (FETEX-150)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
AAllowed
DDisallowed

Element: 3

Numbering Plan Area Code

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 4

Central Office Code

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 5

Line Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

4

4

Yes

Yes

Data Parameters:

0000-9999

No.

Element Combination

Series

Separator

1.

1 - 2 SP [ 3 SP [ 4 - 5 , SP ] , SP ]

No

2.

1 - 2 SP [ 4 - 5 , SP ]

No

3.

1 - 2 SP [ 4 - 5 , SP ] , SP [ 3 SP [ 4 - 5 , SP ] , SP ]

No

4.

1 - [ 3 SP [ 4 - 5 , SP ] , SP ]

No

5.

1 - [ 4 - 5 , SP ]

No

6.

1 - [ 4 - 5 , SP ] , SP [ 3 SP [ 4 - 5 , SP ] , SP ]

No


SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

1

24

Element: 1

Group Addressing Identifier

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

10

No

No

Data Parameters:

1-9999
or
10 digits in form of NPANXXXXXX

Element: 2

Group Address List Screening Type (FETEX-150)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
AAllowed
DDisallowed

Element: 3

Numbering Plan Area Code

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 4

Central Office Code

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

3

3

No

No

Reference:

See iconectiv LERG Routing Guide for complete list.

Element: 5

Line Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

4

4

Yes

Yes

Data Parameters:

0000-9999

No.

Element Combination

Series

Separator

1.

1

No

2.

2 SP 3 SP [ 4 - 5 , SP ]

Yes

, SP

3.

2 SP [ 4 - 5 , SP ]

Yes

, SP

4.

2 SP [ 4 - 5 , SP ] , SP [ 3 SP [ 4 - 5 , SP ] , SP ]

Yes

, SP

5.

3 SP [ 4 - 5 , SP ]

Yes

, SP

6.

4 - 5

Yes

, SP

7.

[ 4 - 5 , SP ] , SP [ 3 SP [ 4 - 5 , SP ] , SP ]

Yes

, SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

P

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, D,E

I,O, D,E

-

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.