GIAC

GROUP INTERCOM ALL CALLS

INDICATES:

The group intercom all call group number.

DATE:

7/31/2008

BILLING:

CRIS

APPLICATIONS:

CS2000, DMS-100


SECTION - POSITION

EXAMPLES

S&E - FL

DMS-100
I1   @@A/TN 4419/GIC AMMOC1-45
     /GIAC NUM.2345, ORIG.Y

CS2000 (SN07)
I1   @@A/TN 4419/GIC AMMOC1-45
     /GIAC NUM.2345, ORIG.Y,
     PAGING.Y

FID RULES/CONSTRAINTS:

  1. The Group Intercom (GIC) option must be assigned to the set or key before the Group Intercom All Calls (GIAC) option may be assigned.

REFERENCES:

  1. DMS-100
    NORTEL Practice, 297-2101-310, Option GIAC
  2. CS2000 (SN07)
    NORTEL Practice, 297-8021-808, Option GIAC

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

5

26

Element: 1

GIAC Number Attribute Name

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
NUMGroup Number

Element: 2

GIAC Number Attribute Value

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

4

No

No

Data Parameters:

0 - 4095

Element: 3

Allowed to Initiate GIAC Calls Attribute Name

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
ORIGAllowed to Initiate GIAC Calls

Element: 4

Allowed to Initiate GIAC Calls Attribute Value

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

Element: 5

Paging Attribute Name (CS2000 SN07)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

6

6

No

No

Code Set:

CodeMeaning
PAGINGPaging Notification

Element: 6

Paging Attribute Value (CS2000 SN07)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

No.

Element Combination

Series

Separator

1.

1 . 2

No

2.

1 . 2 , SP 3 . 4

No

3.

1 . 2 , SP 3 . 4 , SP 5 . 6

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-

Other FIDs Required Logical Line

GIC

GIC

GIC

GIC

GIC

GIC

GIC

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.