GSZ

GROUP SIZE

INDICATES:

The limit of a stored program control switch's Simulated Facility Group (SFG), Customer Facility Group (CFG), or Maximum Number of Terminals in a Multiline Hunt Group.

DMS-10, DMS-100, CS2000
The maximum number of calls that may be forwarded simultaneously to a Remote Call Forwarding (RCF) appearance.

DATE:

7/29/2010

BILLING:

CRIS and CABS

APPLICATIONS:

1AESS, 5ESS, 800 Service, Access Service, Access Service Request (ASR), AXE, CS2000, DMS-10, DMS-100, EWSD, GTD-5 EAX, Hunting, ISDN BRI, TL1


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@A/TN 732 555-1234/CFG 885/GSZ 6

GTD-5 EAX (MLHG)
IHML 30-TER H1-10/HTY RG
     /TLI 732 555-1234
     /GSZ 10

GTD-5 EAX
I1   @@E/CFN 555-2345/GSZ 6

FID RULES/CONSTRAINTS:

  1. FID must be entered on assignable line USOC logical line.
  2. T, F, and X order types prohibited for Access Service application.
  3. X action code prohibited on Access Service orders.
  4. TL1
    The GSZ FID is not valid for an analog member of an Electronic Key Telephone Set (EKTS).
  5. The FID SFG or CFG is required on the same logical line when a group size is defined for a Simulated Facility Group or  a Customer Facility Group.
  6. GTD-5 EAX
    The GSZ FID is used to define the group size of the multiline hunt group at the Multiline Hunt Group (MLHG) level. When used on the Directory Number/Call Type (DNCT) View, it defines the Remote Call Forwarding Limit.

SERVICE ORDER ACTIVITY NOTES:

  1. 5ESS
    The data entry is provided by the Network Administration Center and supplies data for the ESS Recent Change Message.
  2. TL1, GTD-5 EAX
    When the GSZ FID is used to represent the Remote Call Forwarding Limit (RCFLM keyword), the switch default is "1".  When the SFG GSZ is represented, there is no switch default.

REFERENCES:

  1. EWSD
    Siemens 0625-000730, Call Forwarding Features; Siemens 0770-00010, MBRLIM
  2. TL1
    TR-NWT-000199, DNCT View, Keyword RCFLM; SFG View, Keyword GSZ
  3. AXE
    Ericcson Translations Guide, Div. 5, Sec. 9, Keyword MAX
  4. 5E8 and Later
    Lucent Technologies, 235-118-257, View 7.3, Keyword SFGSIZE
  5. GTD-5 EAX
    AG Communication Systems, MLHG View, Keyword HGSZ; DNCT View, Keyword RCFLM
  6. DMS-10
    NORTEL 297-3601-311P2, DN (RCFA) Prompting Sequence, Prompt MAX
  7. DMS-100, CS2000
    NORTEL 297-8021-808CP, NEWDN Command, Prompt MAXCALLS
  8. ATIS/OBF-ASR-009, GSZ field

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Numeric

1

4

Element: 1

Group Size

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

4

No

No

Data Parameters:

1-5111AESS
1-512EWSD
1-19845ESS Limited Group Size
99995ESS Unlimited Group Size
0-255DMS-10
0-511DMS-100, CS2000
1-999TL1
1-4095FETEX-150
1-64AXE
1-1000GTD-5 EAX Multiline Hunt Group
0-255

GTD-5 EAX Remote Call Forwarding Limit

Element Rules:

In the GTD-5 EAX switch, applicable to only non-BBG lines when used to define Remote Call Forwarding Limit.


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, X,R, M

I,O, C,T, X,R, M,D, E

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.