HML

HUNTING-MULTILINE GROUP NUMBER

INDICATES:

A multiline hunt group number in stored program control switches.

DATE:

9/23/2010

BILLING:

CRIS and CABS

APPLICATIONS:

1AESS, 2ESS, 3ESS, 5ESS, Access Service, Access Service Request (ASR), DMS-100, EWSD, FETEX-150, GTD-5 EAX, Hunting, SanteraOne, STROM-DCO, TL1


SECTION - POSITION

EXAMPLES

S&E - LH

OHML 30-TER H1-4 N3001/HTY RG
     /TLI 732 555-1234
IHML 30-TER H1-3 N3001/HTY RG
     /TLI 732 555-1234

NXX Code Sharing
IHML 31-TER H1-5/EXK 732 555

S&E - FL

I1   @@A/TER 1/HML 31/TLI 732 555-1234
     /EXK 732 555
O1   @@4/TER 4/HML 30/TLI 732 555-2345

ASGM - FL

G1   TER 4/HML 30/TLI 732 555-1234
FA   123 MAIN/RT 145A/PRQ Y
IOE  010-03-22

FID RULES/CONSTRAINTS:

  1. When the main telephone number is not the same as the telephone number associated with the first terminal of a multiline hunt group (i.e., lead telephone number of the multiline hunt group), or the Terminal Number - Multiline Group (TER) FID is not the Primary Line Identifier (PLID), the Telephone Line Identifier (TLI) FID with the lead telephone number of the multiline hunt group as data, must be associated with every specification of the floated Hunting-Multiline Group Number (HML) FID.
  2. A multiline group number is unique to an ESS traffic unit.
  3. Section:  S&E      Position:  FL
    The HML FID must appear with each USOC associated with each line in the Multiline Hunt Group.
  4. Section:  S&E      Position:  LH
    The HML FID must appear left-hand whenever there is an inward or outward action (i.e., I, O, C, X, or T action code) on one or more lines or USOCs associated with the lines in the Multiline Hunt Group.
  5. Section:  S&E      Position:  LH
    The HTY FID must also be entered for all hunting types.
  6. Section:  S&E      Position:  LH
    In 2ESS, non-hunting terminal numbers must be higher than hunting terminal numbers. In 1AESS, the first terminal number must be 1 (see TER FID).
  7. Section:  S&E      Position:  LH
    The terminal numbers appearing as data after the left-hand HML FID must be in ascending, consecutive order.
  8. Section:  ASGM     Position:  FL
    The HML FID and its data are entered with the TER  FID (Terminal Number-Multiline Group) and its data for each line in a multiline group.
  9. Section:  ASGM     Position:  FL
    This FID is entered in the Miscellaneous Subset, Central Office Facilities Subset and Outside Plant Facilities Subset.
  10. For Access Service Tariff application C and T Action Codes cannot be used to change the group number.
  11. T, F, and X order types are prohibited for Access Service application.
  12. X action code prohibited on Access Service orders.
  13. Section:  S&E      Position:  LH, FL
    When NXX Code Sharing is involved, Exchange Key (EXK) is required on left-hand and floated HML logical lines.

REFERENCES:

  1. TL1
    TR-NWT-000199, Subscriber Lines, DNCT, MLHG and MLTERM Views, Keywords MLHG and MLTERM
  2. EWSD
    Siemens 0625-00070, Multiline Hunt Service; Siemens 0770-00010
  3. EWSD - Release 17.0
    Siemens Telecom Networks Requirement Specification, TL1 for MLHGs, P30310-A2445-A016-02-7626, CUG, DC, DNCT, and OEDN Views, Keywords MLHG and MLTERM
  4. GTD-5 EAX
    AG Communication Systems, DNCT and MLHG Views, Keyword MLHG
  5. SanteraOne
    Santera Systems Inc., DNCT View, Keywords MLHG and MLTERM; MLHG View, Keyword MLHG
  6. 5ESS
    Lucent Technologies 235-118-257, Views 1.6, 1.8, 23.2 and 23.8,  Keyword MLHG
  7. ATIS/OBF-ASR-009, HML field

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - LH

Required

Alphanumeric

8

20

Element: 1

Hunting-Multiline Group Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

4

No

No

Data Parameters:

0-20471AESS, SanteraOne
1-2552ESS
0-633ESS
1-20005ESS  (5E14 and Prior)
1-81915ESS (5E15)
1-4095EWSD, FETEX-150
1-2047TL1
0-8191DMS-100
1-5999GTD-5 EAX
1-511DCO

Element Rules:

DMS-100
Multiple Position Hunt (MPH) Group Numbers are 0 to 31 only.

Element: 2

Terminal Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
TERTerminal

Element: 3

Hunting Terminal Indicator

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
HHunting Terminal

Element: 4

Hunting Terminal Number(s)

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

4

Yes

Yes

Data Parameters:

1-20471AESS, 5ESS, EWSD, FETEX-150, TL1, SanteraOne, DCO
0-2552ESS
0-633ESS
0-255DMS-100
1-2015Packet - 5ESS
1-1000GTD-5 EAX

Element Rules:

Must always be in series and/or range except for 5ESS 800 Service or ISDN Attendant (ISAT) Uniform Call Distribution (UCD) hunt type.

Element: 5

Non-Hunting Terminal Indicator

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
NNon-Hunting Terminal

Element Rules:

Required when Non-Hunting Terminal Numbers appear.

Element: 6

Non-Hunting Terminal Numbers

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

Yes

Yes

Data Parameters:

3001-39991AESS Non-Hunting Terminal Numbers
0-2552ESS Non-Hunting Terminal Numbers
0-633ESS Non-Hunting Terminal Numbers

Element Rules:

Required when Non-Hunting Terminal Indicator appears.

No.

Element Combination

Series

Separator

1.

1 - 2 SP 3  4

No

2.

1 - 2 SP 3  4 SP 5  6

No


SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Numeric

1

4

Element: 1

Hunting-Multiline Group Number

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

1

4

No

No

Data Parameters:

0-20471AESS, SanteraOne
1-2552ESS
0-633ESS
1-20005ESS (5E14 and Prior)
1-81915ESS (5E15)
0-8191DMS-100
1-4095EWSD, FETEX-150
1-2047TL1
1-5999GTD-5 EAX
1-511DCO

Element Rules:

DMS-100
Multiple Position Hunt (MPH) Group Numbers are 0 to 31 only.

SECTION - POSITION

ASGM - FL

Please refer to S&E - FL for all data requirements.


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I

I

O

O

I,O, C,T

I,O, C,T

I,O

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, M,X, D,E, R

I,O, C,T, M,X, D,E, R

C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes

Order Section - Position: ASGM - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

P

O

P

P

Action Codes

I

I

O

O

I,O

-

I,O

-

-


CRIS

CABS

Data Retention

No

No

Printed on CSR

No

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.