HSDT |
HIGH SPEED DATA TRUNK |
INDICATES: |
The circuit identification of the Internet Service Provider (ISP) trunk used to support the subscriber's ADSL service. |
DATE: |
11/11/2004 |
BILLING: |
CRIS and CABS |
APPLICATIONS: |
Digital Subscriber Line (DSL) |
SECTION - POSITION |
EXAMPLES |
S&E - FL |
|
I1 @@4/TN 732 555-6666/CISP 1/NETP |
FID RULES/CONSTRAINTS: |
|
SERVICE ORDER ACTIVITY NOTES: |
|
SECTION - POSITION |
APPEARANCE |
MODE |
MIN |
MAX |
S&E - FL |
Required |
Alphanumeric |
7 |
34 |
Element: 1 |
Special Service Circuit Identification in CLCI-S/S Serial Number Format |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Required |
Alphabetic |
3 |
3 |
No |
No |
Code Set: |
||||||
|
Element: 2 |
CLCI Prefix |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
2 |
No |
No |
Reference: |
See BR 795-402-100 for complete list. |
Element: 3 |
CLCI Service Code |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
2 |
2 |
No |
No |
Reference: |
See BR 795-402-100 for complete list. |
Element: 4 |
CLCI Modifier |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
2 |
2 |
No |
No |
Reference: |
See BR 795-402-100 for complete list. |
Element Rules: |
Effective 4/1/01, the industry agreed to combine the 5th and 6th position CLCI S/S modifiers into one, 2-character, alphanumeric data element to increase coding power. |
Element: 5 |
CLCI Serial Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
6 |
No |
No |
Data Parameters: |
||
|
Element: 6 |
CLCI Suffix |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Numeric |
1 |
3 |
Yes |
Yes |
Data Parameters: |
||
|
Element Rules: |
Series and range usage is approved for use for Access Service Tariff application and Primary Rate ISDN. |
Element: 7 |
COMMON LANGUAGE Company Assigning Circuit Identification |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphabetic |
2 |
4 |
No |
No |
Reference: |
See BR 751-100-112 for complete list. |
Element: 8 |
CLCI Segment Name |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
1 |
3 |
No |
No |
Data Parameters: |
||||
|
Element Rules: |
The data element is required behind the FID SGN. If this element appears as part of the data following CLS, it must be identical to the data following the SGN FID. |
Element: 9 |
Circuit Number |
Appearance |
Mode |
Min |
Max |
Series |
Range |
Optional |
Alphanumeric |
3 |
30 |
No |
No |
Symbols: |
Hyphen, Period, Space |
Element Rules: |
Format of this element should match the circuit number as expressed within the CKT FID. |
No. |
Element Combination |
Series |
Separator |
1. |
1 SP 2 . 3 4 . 5 . 6 . 7 |
No |
|
2. |
1 SP 2 . 3 4 . 5 . 6 . 7 . 8 |
No |
|
3. |
1 SP 2 . 3 4 . 5 .. 7 |
No |
|
4. |
1 SP 2 . 3 4 . 5 .. 7 . 8 |
No |
|
5. |
1 SP 3 . 4 5 . 6 . 7 |
No |
|
6. |
1 SP 3 . 4 5 . 6 . 7 . 8 |
No |
|
7. |
1 SP 3 . 4 5 . 7 |
No |
|
8. |
1 SP 3 . 4 5 . 7 .. 8 |
No |
|
9. |
1 SP 9 |
No |
ORDER TYPE/ACTION CODE/FID RELATIONSHIPS |
Order Section - Position: S&E - FL
|
Order Type |
N |
T |
F |
D |
C |
R |
X |
P |
A |
Presence |
O |
O |
O |
O |
O |
O |
O |
P |
P |
Action Codes |
I,E |
I,E |
O,D |
O,D |
I,O, C,T, D,E, M,X, R |
I,O, C,T, D,E, M,X, R |
I,O, C,T, R |
- |
- |
CRIS |
CABS |
|
Data Retention |
Yes |
Yes |
Printed on CSR |
Yes |
Yes |
Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure. |
iconectiv Confidential - Restricted Access This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv. |
Licensed Material - Property of iconectiv Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv. |