HST

HOST LOCATION

INDICATES:

The CLLI identification code of the Host location that appears on the remote location when there is routing through a tandem.

DATE:

6/10/2004

BILLING:

CABS

APPLICATIONS:

Access Service


SECTION - POSITION

EXAMPLES

S&E - FL

IG1  ASG 1/OCL PETNILPTRS0
     /PIU 88/HST BCHRILBC
IG2  TSC AB123456/TTD DF4-TDDEF
     /APZ PETNILPTRS0 MM PETNILPT
     /TTC TY/TGN 0444

SERVICE ORDER ACTIVITY NOTES:

  1. The HST FID is used to derive the V&H coordinates from Host to Remote, when the traffic is routed through a tandem and the Host CLLI cannot be determined for recorded usage and mileage measurement.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

8

11

Element: 1

COMMON LANGUAGE Geographical Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

4

4

No

No

Data Parameters:

A-Z

Symbols:

Space

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Geographical Codes created after 11/8/95 must be 4 alpha characters.

Geographical Codes created prior to 11/8/95 were two to four alpha characters.  Two or 3 character codes were left justified and the unused (rightmost) positions were blank filled.  It is for the latter reason the use of the "space" text symbol is permitted and, as a result, the element mode must be shown as "AN".

The actual numeric character values of 0 through 9 are not, nor have they ever been, allowed within the Geographical Code.
Required as specified in BR 795-100-100.

Element: 2

COMMON LANGUAGE Geopolitical Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 3

CLLI Network Site Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic or Numeric

2

2

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

Element: 4

CLLI Network Entity Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

3

No

No

Reference:

See BR 795-100-100 for more information on CLLI codes or go to www.commonlanguage.com/clli.

Element Rules:

Required as specified in BR 795-100-100.

No.

Element Combination

Series

Separator

1.

1  2  3

2

SP

2.

1  2  3  4

2

SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

P

P

O

O

O

P

P

P

Action Codes

I

-

-

O

I,O, R,D, E,C, T

I,O, R,D, E,C, T

-

-

-


CRIS

CABS

Data Retention

No

Yes

Printed on CSR

No

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access