HVA

HIGH VOLTAGE AREA

INDICATES:

Certain lines or circuits are terminated in a high voltage area. Extra caution is required by installation and maintenance personnel to prevent personal injury from electrical shock and to insure continuity of telephone or private line services.

DATE:

12/4/2008

BILLING:

CRIS and CABS

APPLICATIONS:

General Purpose


SECTION - POSITION

EXAMPLES

IDENT - LH

HVA

IDENT - FL

     /HVA GROUND TO LEAD ON TOWER

S&E - FL

I1   @@A/732 555-1234/HVA AVOID CABLE 46T

FID RULES/CONSTRAINTS:

  1. T, F and X order types are prohibited for Access Service application.
  2. X action codes are prohibited on Access Service orders.
  3. Section: IDENT   Position: LH, FL
    The absence of an action code infers the presence of an "I" (IN) action code.   The I action code is optional on the service order.

SERVICE ORDER ACTIVITY NOTES:

  1. HVA instructions are provided by the Electrical Power Company for services terminating on their premises.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

IDENT - LH

Optional

Alphanumeric

0

99

Element: 1

Caution Narrative

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

1

99

No

No


SECTION - POSITION

IDENT - FL

Please refer to IDENT - LH for all data requirements.


SECTION - POSITION

S&E - FL

Please refer to IDENT - LH for all data requirements.


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: IDENT - LH

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

O

P

Action Codes

I

I

I,O

I,O

I,O

I,O

I

I

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes

Order Section - Position: IDENT - FL

 

Please refer to IDENT - LH for Order Type, Action Code, and FID relationships.

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.