ICI

INCOMING CALL IDENTIFIERS

INDICATES:

The type of incoming call an attendant console will answer.

DATE:

9/5/2006

BILLING:

CRIS

APPLICATIONS:

5ESS, DMS-100, ISDN BRI


SECTION - POSITION

EXAMPLES

S&E - FL

5ESS
I1   @@A/TN 732 555-1234/ICI
     1.LDN1, 2.CFDA, 3.WAT1

DMS-100
I1   HML 35 TER H1-15/HTY MP/ICI
     TYPE.0

FID RULES/CONSTRAINTS:

  1. SERIES AND RANGE ENTRIES - PROCESSING
    Service Order Analysis and Control System (SOAC) should process series and range data entries using the DUPLICATE algorithm.

REFERENCES:

  1. 5ESS
    Lucent Technologies 235-118-257, View 23.2, Keyword ICILIST
  2. DMS-100
    NORTEL Practice 297-2101-310, Option MPH, Prompt CALLTYPE.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

4

9

Element: 1

Incoming Call Identifier Number (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

1-16

Element: 2

Incoming Call Identifier Type (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

2

6

No

No

Code Set:

CodeMeaning
ACLASS Automatic Call Back
ARLASS Automatic Recall
CFBLCall Forward Busy Line
CFDACall Forward Don't Answer
CFOHCall Forward - Off Hook
CFVCall Forwarding Variable
CNETCorporate Network Trunk Group
DCLDirect Connect
DSNICNDSN incoming trunk to Centrex Network
EMEREmergency
FTSFederal Telecommunications System
FTSICNFTS-2000 incoming trunk to Centrex Network
FX1-FX8Foreign Exchange Trunk Group
FXICNFX incoming trunk to Centrex Network
ICPTIntercept
INCIIncoming Internal
LDN1-LDN8Local Directory Number 1 through 8
PPEXEC Precedence and Preemption Executive Override
PPFLSHPrecedence and Preemption Flash
PPFOVRPrecedence and Preemption Flash Override
PPIMMDPrecedence and Preemption Immediate
PPPRIOPrecedence and Preemption Priority
PPROUTPrecedence and Preemption Routine
QUEMLHG Queued Call (verify only and not needed for level 1 error message)
RLTRelease Link Trunk
TIE1-TIE8TIE Trunk Group
TIEICNTIE incoming trunk to Centrex Network
WAT1-WAT5Inward WATS 1 through 5

Element: 3

Multiple Position Hunting (MPH) Call Type Indicator (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
TYPECall Type

Element: 4

MPH Call Type Number (DMS-100)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

0-31

No.

Element Combination

Series

Separator

1.

1 . 2

Yes

, SP

2.

3 . 4

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, X,R, M

I,O, C,T, D,E, X,R, M

I,O, C,T, D,E, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.