INT

INTERCOM NUMBER

INDICATES:

The intercommunicating line number assigned to a line or revertive calling capability.

DATE:

5/2/2002

BILLING:

CRIS and CABS

APPLICATIONS:

1AESS, AXE, DMS-100, EWSD


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@E/TN 732 221-2615/INT 15

I1   @@A/TN 732 221-2615/INT 15,
     *01-2615

EWSD
I    @@A/TN 732 529-5051/INT 53#

FID RULES/CONSTRAINTS:

  1. INT FID is redundant with the MVP FID which contains an element for intercom number identification.
  2. The entry of the INT FID without data indicates that the line has revertive calling capability for DMS-100.
  3. T, F, and X order types are prohibited for Access Service application.
  4. X action codes are prohibited on Access Service orders.

REFERENCES:

  1. EWSD
    Siemens 0625-00640, Intercom Dialing; Siemens 0770-00010, DNCOD.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Optional

Alphanumeric

0

18

Element: 1

Intercom Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

8

No

No

Data Parameters:

1-99(1AESS)
1-9999999(EWSD)
1-99999999(AXE)

Element Rules:

EWSD
If intercom number is less than four digits, Element 2 is required.

Element: 2

Call Transfer Code

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

3

No

No

Data Parameters:

Data characteristics are locally developed.

Symbols:

Asterisk, Number Sign

Element Rules:

1AESS
Applicable on 1A switch to facilitate the transfer of calls between the intercom and a central office line. When Element 2 appears, Element 3 must also appear.
EWSD
Number sign is required if intercom number is less than four digits in order for the EWSD to recognize that the dialing sequence has ended.

Element: 3

Line Number

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

4

4

No

No

Data Parameters:

0000-9999

Element Rules:

When Element 3 appears, Element 2 must also appear.

No.

Element Combination

Series

Separator

1.

1

No

2.

1  2

No

3.

1 , SP 2 - 3

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, M,X, D,E, R

I,O, C,T, M,X, D,E, R

-

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.