LCC

LINE CLASS CODE

INDICATES:

The originating and terminating restrictions, or combinations of restrictions, for a line in a stored program controlled switch.

DATE:

10/27/2005

BILLING:

CRIS and CABS

APPLICATIONS:

1AESS, 2ESS, 3ESS, 5ESS, DMS-100, EWSD, FETEX-150, GTD-5 EAX, Hunting, ISDN BRI, ISDN PRI, STROM-DCO, TL1


SECTION - POSITION

EXAMPLES

S&E - FL

I1    @@4/TN 732 555-1234/LCC CBA

TL1-PRI, G4.0
IPRIN|PRI-001/SAB HH/PIC 288/RPOA
      0288/LCC SPH, VI; DAT, CMD

EWSD-MLHG, APS 17.0
IHML  15-TER H1-3/HTY RG/TLI 328-1500
      /LCC CBA

FID RULES/CONSTRAINTS:

  1. Series and Range Entries-Processing
    Service Order Analysis and Control System (SOAC) should process series and range data entries using the DUPLICATE algorithm.
  2. T, F, and X order types prohibited for Access Service application.
  3. X action code prohibited on Access Service orders.

SERVICE ORDER ACTIVITY NOTES:

  1. LCC applies only to assignable line USOCs that are not specific enough to uniquely identify the switch LCC for exchange lines or trunks or Centrex stations.  A maximum of one LCC entry is permitted per USOC line.
  2. TL1
    LCC element 1 is only used in combination with element 2 for Integrated Services Digital Network Primary Rate Interface (ISDN PRI). This defines, at the Interface Level, the LCCs valid on the Interface.
  3. EWSD
    LCC is valid at the hunt group level for Multiline Hunting (MLHG) only.
  4. When LCC appears at the hunt group level, the data following LCC will be propagated to all lines in the hunt group.  If LCC also appears at the line level, the data following the line level FID will be used for the switch translations.
  5. GTD-5EAX
    The LCC value, in combination with other data, is used by MARCH to derive Primary Class of Service (PCOS) and/or Secondary Class of Service (SCOS).

REFERENCES:

  1. 5ESS
    Lucent Technologies 235-118-257, Views 1.6, 1.8 and 4.1, Keyword LCC.
  2. DMS-100
    NORTEL Practice 297-2101-808, Option LCC.
  3. TL1
    TR-NWT-000199, DNCT View, Keyword LCC.
  4. TL1, G4.0
    TR-NWT-000199, DNCT View and PRI View, Keyword LCC.
  5. EWSD
    Siemens 0770-00010, Section 13, LCC.
  6. EWSD (Release 17.0)
    Siemens Telecom Network Requirement Specification, TL1 for MLHGs, P30310-A2445-A016-02-7626, MLHG View, Keyword LCC.
  7. GTD-5 EAX
    AG Communication Systems, DNCT View, Keyword LCC.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

3

13

Element: 1

Line Class Code

Appearance

Mode

Min

Max

Series

Range

Required

Alphanumeric

3

8

No

No

Element Rules:

5ESS
Allows 3 alphanumeric characters
TL1, GTD-5 EAX
Allows a maximum of 4 characters.

Element: 2

Bearer Capability (TL1-PRI, G4.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

3

No

No

Code Set:

CodeMeaning
VIVoice
CMDCircuit Mode Data

No.

Element Combination

Series

Separator

1.

1

No

2.

1 , SP 2

Yes

; SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.