LCL

LOGICAL CHANNEL LAYOUT

INDICATES:

The maximum number of channels and the allocation (high to low range) of the channels associated with an X.25 Link Access Procedure (LAP) or Link Access Procedure Balanced (LAPB) and X.75 access line in a Public Packet Switched Network (PPSN) service, or packet service on 5ESS ISDN. The logical channels and logical channel assignment for packet mode in a generic interface switch (TL1).

DATE:

9/15/2005

BILLING:

CRIS and CABS

APPLICATIONS:

5ESS, Access Service, DMS-100, EWSD, EWSP, ISDN BRI, Public Packet Switched Network (PPSN), TL1


SECTION - POSITION

EXAMPLES

S&E - FL

PPSN
I1   @@H/CLS 10.QSHK.123456..NJ
     /LCL 127; PVC 1-25, 1WI 40-44,
     2WY 50-55, 1WO 76-82

I1   @@H/CLS 10.QSHK.123456..NJ
     /LCL 127; 25 PVC, 5 1WI,
     5 2WY, 6 1WO
I1   @@H/CLS 10.QSHK.123456..NJ
     /LCL O; 2WY L1 H1

5ESS-ISDN  (Starts at Element 4)
I1   @@H/CLS 10.QSHK.123456..NJ
     /LCL HPVC.7; INL.8, INH.15,
     2WL.16, 2WH.100, OUTL.101,
     OUTH.127

DMS PH (Prior to  NA007)       (Starts at Element 9)
I1   @@H/CLS 10.QSHK.123456..NJ
     /LCL LCN.10, PVC.5, OVC.2,
     IVC.3

DMS PH (NA007)  (Starts at Element 42)
I1   @@H/CLS 10.QSHK.123456..NJ/DTN
     732 555-1234/LCL SLCN.546,
     NNRC.240, NPVC.125, NOWI.50,
     NOWO.50/FRLS Y


TL1 - ISDN  (G3.0 and Prior)     (Starts at Element 19)
I1   @@H/CLS 10.QSHK.123456..NJ/LCL
     BDCLC.4090-4095, LCAB.5 PVC 7,
     10 INO 21, 10 OUO 31

TL1 - ISDN  (G4.0)    (Starts at Element 31)
I1   @@H/CLS 10.QSHK.123456..NJ
     /DTN 732 555-1234/LCL LCAODB.LTC 1,
     HTC 8

EWSD, APS 12.0   (Starts at Element 31)
I1   @@H/CLS 10.QSHK.123456..NJ/DTN
     732 555-1234/LCL DCLCAD.0,2, LCAD.
     LTC 1, HTC 2, CLAY.DOWN

EWSP  (Starts at Element 36)
I1   @@H/CLS 10.QSHK.123456..NJ/DTN
     732 555-1234/DSNA 10.IBMX.234567..NJ
     /LCL CMAX.5, CLAY.DOWN, CIN.3,
     COUT.2

FID RULES/CONSTRAINTS:

  1. T and F order types prohibited for Access Service application.
  2. X action code prohibited on Access Service orders.
  3. SERIES AND RANGE ENTRIES - PROCESSING
    Series and range processing on this FID is not appropriate since the USOC logical line will never carry a quantity greater than 1.
  4. DMS PH (NA007)
    The Force Release Indicator (FRLS) FID is required on the same logical line.

SERVICE ORDER ACTIVITY NOTES:

  1. FID and data will float on access line (speed) USOC logical line or ISDN assignable line USOC logical line.

REFERENCES:

  1. Refer to GR-301-CORE, Public Packet Switched Network Generic Requirements (PPSNGR) for additional information.
  2. 5ESS
    Lucent Technologies 235-118-257, Views 23.2 and 23.8 Keywords  HPVCLCN, LINLCN, HINLCN, L2WLCN, H2WLCN, LOUTLCN, HOUTLCN
  3. DMS-100 (Prior to NA007)
    NORTEL Practice 297-2421-310.
  4. DMS PH  (NA007)
    NORTEL Preliminary Document AR2133, Data Network Address (DNA) Parameters: SCLN, NNRC, NPVC, NOWO, NOWI.
  5. TL1 (G3.0)
    TR-NWT-000199, DNCT View, Keywords  BDCLC, DDCLC, LCAB, LCAD.
  6. TL1 (G4.0)
    TR-NWT-000199, DNCT View, Keywords  DCLCAD, DCLCANUPB, DCLCAODB, LCAD, LCANUPB, LCAODB.
  7. EWSP
    Siemens, Stromberg-Carlson, Book P303, CML ADX25, Keywords CMAX, CLAY, CIN, COUT, CPVC.
  8. EWSD
    Siemens, Stromberg-Carlson, 0770-00010 Sections 24 and 25, Keywords LCHDCB, LCHDCD, CHDAT, CHLAY; 1090-00010, Command CR SUB, EDIT PHPROF.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

5

49

Element: 1

Maximum Number of Logical Channels

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1-4096

Element Rules:

Required when the maximum number of channels is not derived from the access line (speed) USOC.

Element: 2

Channel Quantity

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1-4096

Element: 3

Type of Channel (PPSN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

3

No

No

Code Set:

CodeMeaning
PVCPermanent Virtual Circuit
RPVReserved Permanent Virtual Circuit
1WIOne Way Incoming
1WOOne Way Outgoing
2WYTwo Way

Element: 4

Highest Permanent Virtual Circuit (PVC) Logical Channel Number (LCN) Attribute Name (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
HPVCHighest PVC

Element: 5

Highest Permanent Virtual Circuit (PVC) Logical Channel Number Attribute Value (5ESS)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

1-127

Element: 6

Type of Channel (5ESS-ISDN)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

3

4

No

No

Code Set:

CodeMeaning
INLLowest Incoming LCN Assignable
INHHighest Incoming LCN Assignable
2WLLowest 2 Way LCN Assignable
2WHHighest 2 Way LCN Assignable
OUTLLowest Outgoing LCN Assignable
OUTHHighest Outgoing LCN Assignable

Element: 7

Number of Channels

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

Yes

Data Parameters:

1-511
1-1275ESS ISDN

Element Rules:

Required when Switch does not assign channel numbers.

Element: 8

Search Direction

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
HSearch from High to Low
LSearch from Low to High

Element: 9

Logical Channel Number Allocation Order Indicator (DMS PH, Prior to NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
ORDLCL Allocation Order (LCN-ALLOC-ORD DMS-100 Prompt)

Element: 10

Logical Channel Number Allocation Order (DMS PH, Prior to NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
AAscending
DDescending

Element: 11

Logical Channel Number Indicator (DMS PH, Prior to NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
LCNLogical Channel Number (NUMLCN DMS-100 Prompt)

Element: 12

Total Number of Logical Channels (DMS PH, Prior to NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

1-511

Element Rules:

The switch default is 16.

Element: 13

Private Virtual Circuits Indicator (DMS PH, Prior to NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
PVCPrivate Virtual Circuits (NUMPVC DMS-100 Prompt)

Element: 14

Total Number of Private Virtual Circuits (DMS PH, Prior to NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

0-511

Element Rules:

The switch default is zero.

Element: 15

Outgoing Virtual Circuit Indicator (DMS PH, Prior to NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
OVCOutgoing Virtual Circuit (NUMOVC DMS-100 Prompt)

Element: 16

Total Number of Outgoing Virtual Circuits (DMS PH, Prior to NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

0-511

Element Rules:

The switch default is zero.

Element: 17

Incoming Virtual Circuit Indicator (DMS PH, Prior to NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
IVCIncoming Virtual Circuits (NUMIVC DMS-100 Prompt)

Element: 18

Total Number of Incoming Virtual Circuits (DMS PH, Prior to NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

0-511

Element Rules:

The switch default is zero.

Element: 19

B-Channel Direct Call Logical Channels Attribute Name (TL1, G3.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

5

5

No

No

Code Set:

CodeMeaning
BDCLCB-Channel Direct Call Logical Channels

Element: 20

B-Channel Direct Call Logical Channels Attribute Value (TL1, G3.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

Yes

Yes

Data Parameters:

1-4095

Element: 21

Logical Channel Assignment for Packet Mode B-Channel Attribute Name (TL1, G3.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
LCABLogical Channel Assignment for Packet Mode B-Channel

Element: 22

Logical Channel Assignment for Packet Mode B-Channel Quantity of Channels Attribute Value (TL1)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

1-511

Element: 23

Logical Channel Assignment for Packet Mode B-Channel Type of Channel Attribute Value (TL1, G3.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
PVCPermanent Virtual Circuit
INOIncoming Only
OUOOutgoing Only
NRSNo Restriction

Element: 24

Logical Channel Assignment for Packet Mode B-Channel Beginning Channel Number Attribute Value (TL1, G3.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1-4095

Element: 25

D-Channel Direct Call Logical Channels Attribute Name (TL1, G3.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

5

5

No

No

Code Set:

CodeMeaning
DDCLCD-Channel Direct Call Logical Channels

Element: 26

D-Channel Direct Call Logical Channels Attribute Value (TL1, G3.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

Yes

Yes

Data Parameters:

1-4095

Element: 27

Logical Channel Assignment for Packet Mode D-Channel Attribute Name (TL1, G3.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
LCADLogical Channel Assignment for Packet Mode D-Channel

Element: 28

Logical Channel Assignment for Packet Mode D-Channel Quantity of Channels Attribute Value (TL1, G3.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

1-63

Element: 29

Logical Channel Assignment for Packet Mode D-Channel Type of Channel Attribute Value (TL1, G3.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
PVCPermanent Virtual Circuit
INOIncoming Only
OUOOutgoing Only
NRSNo Restriction

Element: 30

Logical Channel Assignment for Packet Mode D-Channel Beginning Channel Number Attribute Value (TL1, G3.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1-4095

Element: 31

Direct Call Logical Channels Attribute Names (TL1, G4.0; EWSD, APS 12.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

6

9

No

No

Code Set:

CodeMeaning
DCLCADD-Channel Assignment (TL1, G4.0; EWSD, APS 12.0)
DCLCANUPBNailed Up B-Channel Assignment (TL1, G4.0; EWSD, APS 12.0)
DCLCAODBOn Demand B-Channel Assignment (TL1, G4.0)

Element: 32

Direct Call Logical Channels Range Attribute Value (TL1, G4.0; EWSD, APS 12.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

Yes

Yes

Data Parameters:

1-4095

Element: 33

Logical Channel Assignment Attribute Names (TL1, G4.0; EWSD, APS 12.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

7

No

No

Code Set:

CodeMeaning
LCADD-Channel Assignment (TL1, G4.0; EWSD, APS 12.0)
LCANUPBNailed Up B-Channel Assignment (TL1, G4.0; EWSD APS 12.0)
LCAODBOn Demand B-Channel Assignment (TL1, G4.0)

Element: 34

Logical Channel Assignment Channel Type Attribute Value (TL1, G4.0; EWSD, APS 12.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
LPVLowest PVC Channel
HPVHighest PVC Channel
LICLowest Incoming Channel
HICHighest Incoming Channel
LTCLowest Two-Way Channel
HTCHighest Two-Way Channel
LOCLowest Outgoing Channel
HOCHighest Outgoing Channel

Element: 35

Logical Channel Assignment Channel Number Attribute Values (TL1, EWSD)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

0-4095

Element Rules:

The switch defaults when element 34 code sets LPV, HPV, LIC, HIC, LOC, and HOC appear are 0.  The switch defaults when element 34 code sets LTC and HTC appear are 1.

Element: 36

Maximum Number of Logical Channels Indicator (EWSP)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
CMAXMaximum Number of Logical Channels

Element: 37

Maximum Number of Logical Channels (EWSP)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1-4095(B-Channel values)
1-64(D-Channel values)

Element: 38

Data Communications Equipment (DCE) Logical Channel Layout Search Direction Indicator (EWSP; EWSD, APS 12.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
CLAYDCE Logical Channel Layout Search Direction

Element: 39

DCE Logical Channel Layout Search Direction (EWSP; EWSD, APS 12.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

4

No

No

Code Set:

CodeMeaning
UPUp
DOWNDown

Element Rules:

The switch default is UP.

Element: 40

Logical Channel Assignment Channel Type Indicator (EWSP)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

4

No

No

Code Set:

CodeMeaning
CINNumber of one way logical channels DCE incoming
COUTNumber of one way logical channels DCE outgoing
CPVCHighest logical channel number reserved for PVC

Element: 41

Logical Channel Assignment Channel Number (EWSP)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

0-64

Element Rules:

The switch defaults for CIN, COUT, and CPVC are 0.

Element: 42

Start Logical Channel Number Attribute Name (DMS PH, NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
SCLNStart Logical Channel Number

Element: 43

Start Logical Channel Number Attribute Value (DMS PH, NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

4

No

No

Data Parameters:

1-4095

Element: 44

Number of Non-Restricted Channel Attribute Name (DMS PH, NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
NNRCNumber of Non-Restricted Calls

Element: 45

Number of Non-Restricted Channel Attribute Value (DMS PH, NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

1-511

Element: 46

Number of Permanent Virtual Circuit (PVC) Attribute Name (DMS PH, NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
NPVCNumber of PVC

Element: 47

Number of PVC Attribute Value (DMS PH, NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

0-511

Element: 48

Number of One Way Incoming Logical Channel Attribute Name (DMS PH, NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
NOWINumber of One Way Incoming Logical Channels

Element: 49

Number of One Way Incoming Logical Channel Attribute Value (DMS PH, NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

0-511

Element: 50

Number of One Way Outgoing Logical Channel Attribute Name (DMS PH, NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
NOWONumber of One Way Outgoing

Element: 51

Number of One Way Outgoing Logical Channel Attribute Value (DMS PH, NA007)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

0-511

No.

Element Combination

Series

Separator

1.

1 ; SP 2 SP 3

No

2.

1 ; SP 2 SP 3 , SP 2 SP 3

No

3.

1 ; SP 2 SP 3 , SP 2 SP 3 , SP 2 SP 3

No

4.

1 ; SP 2 SP 3 , SP 2 SP 3 , SP 2 SP 3 , SP 2 SP 3

No

5.

1 ; SP 2 SP 3 SP 7

No

6.

1 ; SP 3 SP 7

No

7.

1 ; SP 3 SP 7 , SP 3 SP 7

No

8.

1 ; SP 3 SP 7 , SP 3 SP 7 , SP 3 SP 7

No

9.

1 ; SP 3 SP 7 , SP 3 SP 7 , SP 3 SP 7 , SP 3 SP 7

No

10.

1 ; SP 3 SP 8  7 SP 8  7

No

11.

1 ; SP 3 SP 8  7 SP 8  7 , SP 3 SP 8  7 SP 8  7

No

12.

1 ; SP 3 SP 8  7 SP 8  7 , SP 3 SP 8  7 SP 8  7 , SP 3 SP 8  7 SP 8  7

No

13.

2 SP 3

4

, SP

14.

3 SP 7

4

, SP

15.

3 SP 7 SP 8

No

16.

4 . 5 ; SP [ 6 . 7 , SP ]

No

17.

6 . 7

6

, SP

18.

9 . 10

No

19.

9 . 10 , SP 11 . 12

No

20.

9 . 10 , SP 11 . 12 , SP 13 . 14

No

21.

9 . 10 , SP 11 . 12 , SP 13 . 14 , SP 15 . 16

No

22.

9 . 10 , SP 11 . 12 , SP 13 . 14 , SP 15 . 16 , SP 17 . 18

No

23.

9 . 10 , SP 11 . 12 , SP 15 . 16 , SP 17 . 18

No

24.

9 . 10 , SP 11 . 12 , SP 17 . 18

No

25.

9 . 10 , SP 13 . 14

No

26.

9 . 10 , SP 13 . 14 , SP 15 . 16

No

27.

9 . 10 , SP 13 . 14 , SP 15 . 16 , SP 17 . 18

No

28.

9 . 10 , SP 13 . 14 , SP 17 . 18

No

29.

9 . 10 , SP 15 . 16

No

30.

9 . 10 , SP 15 . 16 , SP 17 . 18

No

31.

9 . 10 , SP 17 . 18

No

32.

11 . 12

No

33.

11 . 12 , SP 13 . 14

No

34.

11 . 12 , SP 13 . 14 , SP 15 . 16

No

35.

11 . 12 , SP 13 . 14 , SP 15 . 16 , SP 17 . 18

No

36.

11 . 12 , SP 13 . 14 , SP 17 . 18

No

37.

11 . 12 , SP 15 . 16 , SP 17 . 18

No

38.

11 . 12 , SP 17 . 18

No

39.

13 . 14

No

40.

13 . 14 , SP 15 . 16

No

41.

13 . 14 , SP 15 . 16 , SP 17 . 18

No

42.

13 . 14 , SP 17 . 18

No

43.

15 . 16

No

44.

15 . 16 , SP 17 . 18

No

45.

17 . 18

No

46.

19 . 20

No

47.

19 . 20 , SP 21 . [ 22 SP 23 SP 24 , SP ]

No

48.

25 . 26

No

49.

25 . 26 , SP 27 . [ 28 SP 29 SP 30 , SP ]

No

50.

31 . 32

No

51.

31 . 32 , SP 33 . [ 34 SP 35 , SP ]

No

52.

31 . 32 , SP 33 . [ 34 SP 35 , SP ] , SP 38 . 39

No

53.

31 . 32 , SP 38 . 39

No

54.

33 . [ 34 SP 35 , SP ]

No

55.

33 . [ 34 SP 35 , SP ] , SP 38 . 39

No

56.

36 . 37

No

57.

36 . 37 , SP 38 . 39

No

58.

36 . 37 , SP 38 . 39 , SP [ 40 . 41 , SP ]

No

59.

36 . 37 , SP [ 40 . 41 , SP ]

No

60.

42 . 43 , SP 44 . 45 , SP 46 . 47 , SP 48 . 49 , SP 50 . 51

No


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

P

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

-

-

-


CRIS

CABS

Data Retention

Yes

Yes

Printed on CSR

Yes

Yes




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.