LKLD

LINK LEVEL PARAMETERS D-CHANNEL

INDICATES:

The data link (Layer 2) parameters for an Integrated Services Digital Network (ISDN) D-Channel basic rate interface (pipe) in a generic stored program controlled switch.

DATE:

12/8/2005

BILLING:

CRIS

APPLICATIONS:

EWSD, ISDN BRI, ISDN PRI, Public Packet Switched Network (PPSN), TL1


SECTION - POSITION

EXAMPLES

S&E - FL

TL1
I1   @@F/CLS 10.IBZX.123456..NJ/BS DMD
     DMD SX/BCN SP 3AU 64C PMD/LKLD
     SPN, DES, ANOT, LO.DYNPAL

EWSD, Release 10.0, 10.5, and 11.0
I1   @@F/CLS 10.IBZX.123456..NJ/BS DMD
     DMD SX/BCN SP 3AU 64C PMD/LKLD
     DES, LO.DYNPAL

EWSD, Release 12.0
I1   @@F/CLS 10.IBZX.123456..NJ/BS DMD
     DMD SX/BCN SP 3AU 64C PMD/LKLD
     LO.FLO

REFERENCES:

  1. TL1
    TR-NWT-000199, OE View, Keywords ANOT, D1, D2, DES, LO, NSL, P1, P2, PDD, SPN; PRI View, Keyword PDD.
  2. EWSD, Release 10.0, 10.5, and 11.0
    Siemens, Stromberg-Carlson, 0770-00010, Section 24, Keywords L2COS, LINKOPT, NSL, NCCSL, NPCSL.
  3. EWSD, Release 12.0 and Later
    Siemens, Stromberg-Carlson, 0770-00010, Section 24, Keywords LINKOPT, NSL, NCCSL, NPCSL; 1090-00010 Command CR ACCESS.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

3

45

Element: 1

Subscription Parameter Attribute Name (TL1; EWSD, Release 10.0, 10.5, and 11.0)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

4

Yes

No

Code Set:

CodeMeaning
SPNSignaling Parameter Negotiation (TL1)
DESDiagnostic Error Signaling (TL1; EWSD, Release 10.0, 10.5, and 11.0)
ANOTAutomatic Notification (TL1)

Element Rules:

The appearance of the code set indicates a Yes value.
The switch default for these code sets is "No".
When code set ANOT appears, code set SPN is also required.

Element: 2

Link Option Attribute Name (TL1; EWSD, Release 10.0 and Later)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

2

2

No

No

Code Set:

CodeMeaning
LOLink Option

Element: 3

Link Option Attribute Value (TL1; EWSD, Release 10.0 and Later)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

6

No

No

Code Set:

CodeMeaning
DYNDynamic Links without Packet Links (TL1; EWSD, Release 10.0 and Later)
DYNPALDynamic Links with Packet Links (TL1; EWSD, Release 10.0 and Later)
FLOFixed Link Option (EWSD, Release 10.0 and Later)

Element Rules:

TL1
The switch default for LO is DYN.

Element: 4

Packet Mode Data (PMD) Terminating on the D-Channel Attribute Name (TL1-BRI and PRI)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
PDDPMD Terminating on the D-Channel

Element: 5

Packet Mode Data (PMD) Terminating on the D-Channel Attribute Value (TL1-BRI and PRI)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

Element Rules:

TL1-BRI
The switch default is Y.
TL1-PRI
The switch default is N.

Element: 6

Number of Signaling Links Attribute Name (TL1; EWSD, Release 10.0 and Later)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
NSLNumber of Signaling Links

Element: 7

Number of Signaling Links Attribute Value (TL1; EWSD, Release 10.0 and Later)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

3

No

No

Data Parameters:

3-256(TL1)
3-26(EWSD, Release 10.0 and Later)

Element Rules:

TL1
The switch default for NSL is 10 when LO equals DYN, and 18 when LO equals DYNPAL.
The value for NSL must be less than or equal to the sum of the values of D1+D2+P1+P2 (elements 8-11).
EWSD, Release 10.0 and Later
The NSL range is 3-10 when LO equals DYN, and the switch default is 10.
The NSL range is 4-26 when LO equals DYNPAL, and the switch default NSL is 18.
NSL is not administrable and is fixed at 3, when LO equals FLO.
The value for NSL must be less than or equal to the sum of the values of D1+D2+P1+P2 (elements 8-11) plus 2.

Element: 8

Terminal End Point Identifier (TEI) User Assigned Attribute Name (TL1; EWSD, Release 10.0 and Later)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

2

2

No

No

Code Set:

CodeMeaning
D1User Assigned Call Control
P1User Assigned Packet Control

Element Rules:

EWSD, TL1
P1 is only valid when LO equals DYNPAL.

Element: 9

TEI User Assigned Attribute Value (TL1; EWSD, Release 10.0 and Later)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

0-64(TL1)
0-16(P1 EWSD, Release 10.0 and Later)
0-8(D1 EWSD, Release 10.0 and Later)

Element Rules:

TL1
The switch default for D1 is 8 when LO equals DYN or DYNPAL.
The switch default for P1 is 0 when LO equals DYN and 8 when LO equals DYNPAL.
EWSD, Release 10.0 and Later
The switch default for D1 is 4 when LO equals DYN or DYNPAL, and 1 when LO equals FLO.
The switch default for P1 is 0 when LO equals DYN, 8 when LO equals DYNPAL, and 1 when LO equals FLO.

Element: 10

TEI Switch Assigned Attribute Name (TL1; EWSD, Release 10.0 and Later)

Appearance

Mode

Min

Max

Series

Range

Optional

Alphanumeric

2

2

No

No

Code Set:

CodeMeaning
D2Switch Assigned Call Control (EWSD, TL1)
P2Switch Assigned Packet Control (EWSD, TL1)

Element Rules:

TL1; EWSD, Release 10.0 and Later
P2 is only valid when LO equals DYNPAL.

Element: 11

TEI Switch Assigned Attribute Value (TL1; EWSD, Release 10.0 and Later)

Appearance

Mode

Min

Max

Series

Range

Optional

Numeric

1

2

No

No

Data Parameters:

0-63(TL1)
0-16(P2 EWSD, Release 10.0 and Later)
0-8(D2 EWSD, Release 10.0 and Later)

Element Rules:

TL1
The switch default for D2 is 8 when LO equals DYN or DYNPAL.
The switch default for P2 is 0 when LO equals DYN and 8 when LO equals DYNPAL.
EWSD, Release 10.0 and Later
The switch default for D2 is 4 when LO equals DYN or DYNPAL, and 0 when LO equals FLO.
The switch default for P2 is 0 when LO equals DYN or FLO, and 8 when LO equals DYNPAL.

No.

Element Combination

Series

Separator

1.

1

Yes

, SP

2.

1 , SP 2 . 3

No

3.

1 , SP 2 . 3 , SP 4 . 5

No

4.

1 , SP 2 . 3 , SP 4 . 5 , SP 6 . 7

No

5.

1 , SP 2 . 3 , SP 4 . 5 , SP 6 . 7 , SP [ 8 . 9 , SP ]

No

6.

1 , SP 2 . 3 , SP 4 . 5 , SP 6 . 7 , SP [ [ 8 . 9 , SP ] , SP [ 10 . 11 , SP ] , SP ]

No

7.

1 , SP 2 . 3 , SP 4 . 5 , SP 6 . 7 , SP [ 10 . 11 , SP ]

No

8.

1 , SP 2 . 3 , SP 4 . 5 , SP [ 10 . 11 , SP ]

No

9.

1 , SP 2 . 3 , SP 6 . 7

No

10.

1 , SP 2 . 3 , SP 6 . 7 , SP [ 8 . 9 , SP ]

No

11.

1 , SP 2 . 3 , SP 6 . 7 , SP [ [ 8 . 9 , SP ] , SP [ 10 . 11 , SP ] , SP ]

No

12.

1 , SP 2 . 3 , SP 6 . 7 , SP [ 10 . 11 , SP ]

No

13.

1 , SP 2 . 3 , SP [ 10 . 11 , SP ]

No

14.

1 , SP 4 . 5

No

15.

1 , SP 4 . 5 , SP 6 . 7

No

16.

1 , SP 4 . 5 , SP 6 . 7 , SP [ 8 . 9 , SP ]

No

17.

1 , SP 4 . 5 , SP 6 . 7 , SP [ [ 8 . 9 , SP ] , SP [ 10 . 11 , SP ] , SP ]

No

18.

1 , SP 4 . 5 , SP 6 . 7 , SP [ 10 . 11 , SP ]

No

19.

1 , SP 4 . 5 , SP [ 8 . 9 , SP ]

No

20.

1 , SP 4 . 5 , SP [ [ 8 . 9 , SP ] , SP [ 10 . 11 , SP ] , SP ]

No

21.

1 , SP 4 . 5 , SP [ 10 . 11 , SP ]

No

22.

1 , SP 6 . 7

No

23.

1 , SP 6 . 7 , SP [ 8 . 9 , SP ]

No

24.

1 , SP 6 . 7 , SP [ [ 8 . 9 , SP ] , SP [ 10 . 11 , SP ] , SP ]

No

25.

1 , SP 6 . 7 , SP [ 10 . 11 , SP ]

No

26.

1 , SP [ 8 . 9 , SP ]

No

27.

1 , SP [ [ 8 . 9 , SP ] , SP [ 10 . 11 , SP ] , SP ]

No

28.

1 , SP [ 10 . 11 , SP ]

No

29.

2 . 3

No

30.

2 . 3 , SP 4 . 5

No

31.

2 . 3 , SP 4 . 5 , SP 6 . 7

No

32.

2 . 3 , SP 4 . 5 , SP 6 . 7 , SP [ 8 . 9 , SP ]

No

33.

2 . 3 , SP 4 . 5 , SP 6 . 7 , SP [ [ 8 . 9 , SP ] , SP [ 10 . 11 , SP ] , SP ]

No

34.

2 . 3 , SP 4 . 5 , SP 6 . 7 , SP [ 10 . 11 , SP ]

No

35.

2 . 3 , SP 6 . 7

No

36.

2 . 3 , SP 6 . 7 , SP [ 8 . 9 , SP ]

No

37.

2 . 3 , SP 6 . 7 , SP [ [ 8 . 9 , SP ] , SP [ 10 . 11 , SP ] , SP ]

No

38.

2 . 3 , SP 6 . 7 , SP [ 10 . 11 , SP ]

No

39.

2 . 3 , SP [ 8 . 9 , SP ]

No

40.

2 . 3 , SP [ [ 8 . 9 , SP ] , SP [ 10 . 11 , SP ] , SP ]

No

41.

4 . 5

No

42.

4 . 5 , SP 6 . 7

No

43.

4 . 5 , SP 6 . 7 , SP [ 8 . 9 , SP ]

No

44.

4 . 5 , SP 6 . 7 , SP [ [ 8 . 9 , SP ] , SP [ 10 . 11 , SP ] , SP ]

No

45.

4 . 5 , SP 6 . 7 , SP [ 10 . 11 , SP ]

No

46.

4 . 5 , SP [ 8 . 9 , SP ]

No

47.

4 . 5 , SP [ [ 8 . 9 , SP ] , SP [ 10 . 11 , SP ] , SP ]

No

48.

4 . 5 , SP [ 10 . 11 , SP ]

No

49.

6 . 7

No

50.

6 . 7 , SP [ 8 . 9 , SP ]

No

51.

6 . 7 , SP [ [ 8 . 9 , SP ] , SP [ 10 . 11 , SP ] , SP ]

No

52.

6 . 7 , SP [ 10 . 11 , SP ]

No

53.

8 . 9

Yes

, SP

54.

[ 8 . 9 , SP ] , SP [ 10 . 11 , SP ]

Yes

, SP

55.

10 . 11

Yes

, SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I,E

I,E

O,D

O,D

I,O, C,T, D,E, M,X, R

I,O, C,T, D,E, M,X, R

I,O, C,T, R

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.