LMON

LIST OF MONITORED TELEPHONE NUMBERS

INDICATES:

The list of telephone numbers (TNs) which are to be monitored by a Telephone Status Monitoring and Select (TSMS) provisioned TN.

DATE:

11/10/2005

BILLING:

CRIS

APPLICATIONS:

5ESS, ISDN BRI


SECTION - POSITION

EXAMPLES

S&E - FL

I1   @@A/TN 732 555-1000/LMON
     5551243, DSS.Y, RING.Y;
     5551244, DSS.Y, RING.N;
     5551247, DSS.Y, RING.Y;
     5551251, DSS.N, RING.N;
     5551252, DSS.Y, RING.Y
I1   @@A++/TN 732 555-1100/LMON
     5551255, DSS.N, RING.N;
     5551256, DSS.Y, RING.Y;
     5551258, DSS.N, RING.N

FID RULES/CONSTRAINTS:

  1. A maximum of five monitored TNs may be specified with each usage of the LMON FID.  To provision up to 150 additionally monitored TNs, multiple provisioning USOC lines may be used each containing a single instance of the LMON FID.

REFERENCES:

  1. Lucent Technologies 235-118-257, View 23.24, Keywords MONITOREDLIST, DSS, RING.

SECTION - POSITION

APPEARANCE

MODE

MIN

MAX

S&E - FL

Required

Alphanumeric

22

25

Element: 1

Monitored TN

Appearance

Mode

Min

Max

Series

Range

Required

Numeric

7

10

No

No

Element Rules:

Monitored TN is either 7 or 10 digits.

Element: 2

Direct Station Select Attribute Name

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

3

3

No

No

Code Set:

CodeMeaning
DSSDirect Station Selection

Element: 3

Direct Station Selection Attribute Value

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

Element: 4

Ring (Audible Alerting) Attribute Name

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

4

4

No

No

Code Set:

CodeMeaning
RINGRing (Audible Alert)

Element: 5

Ring (Audible Alert) Attribute Value

Appearance

Mode

Min

Max

Series

Range

Required

Alphabetic

1

1

No

No

Code Set:

CodeMeaning
YYes
NNo

No.

Element Combination

Series

Separator

1.

1 , SP 2 . 3 , SP 4 . 5

5

; SP


ORDER TYPE/ACTION CODE/FID RELATIONSHIPS

Order Section - Position: S&E - FL

 

Order Type

N

T

F

D

C

R

X

P

A

Presence

O

O

O

O

O

O

O

P

P

Action Codes

I

I

O

O

I,O,

I,O

I,O

-

-


CRIS

CABS

Data Retention

Yes

No

Printed on CSR

Yes

No




Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure.




iconectiv Confidential - Restricted Access

This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv.

Licensed Material - Property of iconectiv

Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv.