LRF |
LINE RESTRICTIONS AND FEATURES |
|
INDICATES: |
A combination of line restrictions and features associated with Dimension PBX stations. |
|
DATE: |
10/31/2014 |
|
BILLING: |
CRIS |
|
APPLICATIONS: |
Private Branch Exchange Service (PBX) |
|
SECTION - POSITION |
EXAMPLES |
|
S&E - LH |
|
|
ILRF 1-LR CRL2, DID, TOLL; MTRG 1, |
|
SECTION - POSITION |
APPEARANCE |
MODE |
MIN |
MAX |
|
S&E - LH |
Required |
Alphanumeric |
7 |
46 |
|
Element: 1 |
Line Restrictions and Line Features Group Number |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Required |
Numeric |
1 |
2 |
No |
No |
|
Data Parameters: |
||
|
||
|
Element: 2 |
Line Restrictions Indicator |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Optional |
Alphabetic |
2 |
2 |
No |
No |
|
Code Set: |
||||
|
|
Element Rules: |
|
Required when Line Restrictions appear. |
|
Element: 3 |
Line Restrictions |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Optional |
Alphanumeric |
2 |
8 |
Yes |
No |
|
Code Set: |
||||||||||||||||||||||||||||||||||||||||||||||
|
|
Symbols: |
|
Space |
|
Element: 4 |
Miscellaneous Trunk Restriction Group Indicator |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Optional |
Alphabetic |
4 |
4 |
No |
No |
|
Code Set: |
||||
|
|
Element Rules: |
|
Required when Miscellaneous Trunk Restriction Group appears. |
|
Element: 5 |
Miscellaneous Trunk Restriction Group |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Optional |
Numeric |
1 |
1 |
Yes |
Yes |
|
Data Parameters: |
||
|
||
|
Element: 6 |
Line Features Indicator |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Optional |
Alphabetic |
2 |
2 |
No |
No |
|
Code Set: |
||||
|
|
Element Rules: |
|
Required when Line Features appear. |
|
Element: 7 |
Line Features |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Optional |
Alphabetic |
2 |
6 |
Yes |
No |
|
Code Set: |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Symbols: |
|
Space |
|
Element Rules: |
|
If the code HLS is in a series of Element 7 entries, it must appear as the last entry. |
|
Element: 8 |
Numbering Plan Area Code |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Optional |
Numeric |
3 |
3 |
No |
No |
|
Reference: |
|
See iconectiv LERG Routing Guide for complete list. |
|
Element Rules: |
|
Required when HLS (Hot Line Service) number requires an NPA. |
|
Element: 9 |
Central Office Code |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Optional |
Numeric |
3 |
3 |
No |
No |
|
Reference: |
|
See iconectiv LERG Routing Guide for complete list. |
|
Element Rules: |
|
Required when HLS (Hot Line Service) number requires an NNX. |
|
Element: 10 |
Line Number |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Optional |
Numeric |
4 |
4 |
No |
No |
|
Data Parameters: |
||
|
||
|
Element Rules: |
|
Required when HLS (Hot Line Service) requires a line number. |
|
Element: 11 |
PBX Station Line Indicator |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Optional |
Alphabetic |
3 |
3 |
No |
No |
|
Code Set: |
||||
|
|
Element Rules: |
|
Required when HLS (Hot Line Service) number is PBX. |
|
Element: 12 |
PBX Station Line Number |
|
Appearance |
Mode |
Min |
Max |
Series |
Range |
|
Optional |
Numeric |
1 |
4 |
No |
No |
|
Element Rules: |
|
Required when HLS (Hot Line Service) number is a PBX. |
|
No. |
Element Combination |
Series |
Separator |
|
1. |
1 - 2 SP 3 |
No |
|
|
2. |
1 - 2 SP 3 ; SP 4 SP 5 |
No |
|
|
3. |
1 - 2 SP 3 ; SP 4 SP 5 ; SP 6 SP 7 |
No |
|
|
4. |
1 - 2 SP 3 ; SP 4 SP 5 ; SP 6 SP 7 SP 8 SP 9 - 10 |
No |
|
|
5. |
1 - 2 SP 3 ; SP 4 SP 5 ; SP 6 SP 7 SP 9 - 10 |
No |
|
|
6. |
1 - 2 SP 3 ; SP 4 SP 5 ; SP 6 SP 7 SP 10 |
No |
|
|
7. |
1 - 2 SP 3 ; SP 4 SP 5 ; SP 6 SP 7 SP 11 SP 12 |
No |
|
|
8. |
1 - 2 SP 3 ; SP 6 SP 7 |
No |
|
|
9. |
1 - 2 SP 3 ; SP 6 SP 7 SP 8 SP 9 - 10 |
No |
|
|
10. |
1 - 2 SP 3 ; SP 6 SP 7 SP 9 - 10 |
No |
|
|
11. |
1 - 2 SP 3 ; SP 6 SP 7 SP 10 |
No |
|
|
12. |
1 - 2 SP 3 ; SP 6 SP 7 SP 11 SP 12 |
No |
|
|
13. |
1 - 4 SP 5 |
No |
|
|
14. |
1 - 4 SP 5 ; SP 6 SP 7 |
No |
|
|
15. |
1 - 4 SP 5 ; SP 6 SP 7 SP 8 SP 9 - 10 |
No |
|
|
16. |
1 - 4 SP 5 ; SP 6 SP 7 SP 9 - 10 |
No |
|
|
17. |
1 - 4 SP 5 ; SP 6 SP 7 SP 10 |
No |
|
|
18. |
1 - 4 SP 5 ; SP 6 SP 7 SP 11 SP 12 |
No |
|
|
19. |
1 - 6 SP 7 |
No |
|
|
20. |
1 - 6 SP 7 SP 8 SP 9 - 10 |
No |
|
|
21. |
1 - 6 SP 7 SP 9 - 10 |
No |
|
|
22. |
1 - 6 SP 7 SP 10 |
No |
|
|
23. |
1 - 6 SP 7 SP 11 SP 12 |
No |
|
ORDER TYPE/ACTION CODE/FID RELATIONSHIPS |
|
Order Section - Position: S&E - LH
|
|
Order Type |
N |
T |
F |
D |
C |
R |
X |
P |
A |
|
Presence |
O |
O |
O |
O |
O |
O |
P |
P |
P |
|
Action Codes |
I |
I |
O |
O |
I,O |
I,O |
- |
- |
- |
|
CRIS |
CABS |
|
|
Data Retention |
Yes |
No |
|
Printed on CSR |
Yes |
No |
|
Note: Please refer to BR-751-000-150 for a complete description of a FID specification and its structure. |
|
iconectiv Confidential - Restricted Access This document and the confidential information it contains shall not be distributed, routed or made available to any third party, except with written permission of iconectiv. |
|
Licensed Material - Property of iconectiv Possession and/or use of this material is subject to the provisions of a written license agreement with iconectiv. |